Sec. 32.37. Nonresidential Buildings - Substantial Improvement.

About this text

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

(a) Prohibition. Substantial Improvement of principal buildings, including manufactured homes shall not be allowed within the limits of the future-conditions floodplain unless all requirements of this Article (Sections 32.25, 32.26, 32.27, 32.28, and 32.29)

have been met.

(b) Elevation of Lowest Floor. For substantial improvements that have met all of the requirements of this Article (Sections 32.25, 32.26, 32.27, 32.28, and

32.29), the elevation of the lowest floor, including basement and access to the building, shall be at least one (1) foot above the level of the base flood elevation or at least as high as the future-conditions flood elevation, whichever is higher. Should solid foundation perimeter walls be used to elevate the structure, openings sufficient to equalize the hydrologic flood forces on exterior walls and to facilitate the unimpeded movements of floodwaters shall be

provided in accordance with standards of Section 32.32(a), (b), and (c) of this Article. Substantial improvements that have met all of the requirements of this Article (Sections 32.25, 32.26, 32.27, 32.28 and

32.29) may be floodproofed in lieu of elevation. The structure, together with attendant utility and sanitary facilities, must be designed to be watertight to one

(1) foot above the base flood elevation, or at least as high as the future-conditions flood elevation, whichever is higher, with walls substantially impermeable to the passage of water and structural components

having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy.

(c) Certification. A registered Professional Engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions above, and shall provide such certification to the Zoning Administrator.

History

The history line the source prints at the end of the section.

(Ord. No. 578, § 1, 8-1-2019)