Skip to content
Georgia Commons
Menu

Fort Oglethorpe · Zoning Ordinance

Appendix A - UNIFIED DEVELOPMENT CODE / Chapter 4 - LOT AND BUILDING STANDARDS / Article 2 - DIMENSIONAL REQUIREMENTS BY ZONING DISTRICT

Sec. 2.2. Specific requirements for R-4 zoning district.

About this text

  • As published by Municode, current through 2026-03-26
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

(a) Applicability. In addition to requirements for manufactured homes in chapter 3, Restrictions on Particular Uses and other applicable regulations in this development code, the following requirements in this section shall apply in the R-4 zoning district.

(b) Manufactured home subdivisions.

(1) Manufactured home site area requirements. Every principal building shall be located on a lot or parcel of land having an area of not less than 6,000 square feet, provided that the R-4 district is served by an approved community public water supply and wastewater treatment system.

(2) Front yard (setback from front property line). There shall be a front yard of not less than 25 feet in depth measured from the street right-of-way line (property line to the wall of any principal building).

(3) Rear yard. There shall be a rear yard of not less than ten feet measured from the rear lot line to the wall of any principal building.

(4) Side yard. There shall be a side yard on each side of any dwelling of at least ten feet.

(c) Manufactured home parks.

(1) General requirements. The following general requirements shall apply to the construction or remodeling of all manufactured home parks within the corporate limits of Fort Oglethorpe:

a. Minimum area. A manufactured home park shall have as a minimum size of four acres and shall front upon a public highway or public street.

b. Minimum number of spaces. A manufactured home park shall have as a minimum ten spaces prepared with all utilities in place prior to its approval for occupancy.

c. Length of residential occupancy. No space within a manufactured home park, except as provided below, shall be rented for residential use of a manufactured home except for periods of 30 days or more.

(2) Design. The design of a manufactured home park shall conform to the following design requirements:

a. Density. A maximum of eight manufactured home stands per acre, excluding streets, is allowed.

b. Setback. The manufactured home parks shall be designed so that manufacturers and their accessory structures shall be a minimum distance of 15 feet from adjoining property lines, 20 feet from internal park streets and at least 30 feet from any publicly dedicated street. Manufactured home stands shall be designed so as to provide a distance of at least 20 feet between manufactured homes.

c. Access. The manufactured home park shall front upon at least one publicly dedicated street for a minimum width of 50 feet. Each manufactured home site and its parking area shall have direct access to the internal street system of the park.

d. Streets. Streets within a manufacturing home park shall be privately owned, privately constructed, and privately maintained. Such private streets shall be well drained and provided with a hard-surfaced treatment with a minimum surface of ten feet for one-way streets and 20 feet for two-way streets.

e. Parking. Each manufactured home shall be provided with a minimum of two off-street parking spaces which are side by side. Parking on interior streets within a park is hereby prohibited. The required front yard may be used for the minimum parking; however, required side and rear yards may not be utilized for the minimum parking.

f. Open space. A minimum 30 percent of gross acreage shall be set aside as open space and shall provide recreational areas within said open space. Open space shall not include required front, side or rear yards.

g. Utilities.

1. Sewage. The manufactured home park shall be provided with an approved sewage collection and treatment system.

2. Water. An adequate potable water supply meeting state department of public health requirements shall be provided by the park operator. If a public water system is available at the park site, water service shall be connected to the system.

3. Easements. Publicly dedicated easements of proper size for their intended purpose shall be provided within the park if individual manufactured home stands and accessory park uses are to be serviced by a public system.

4. Utility placement. All water, sewer or gas lines shall be buried a minimum of eight inches below the finished ground surface of the pad area and 24 inches in depth below the finished ground surface of any street right-ofway and shall be provided with adequate valve systems to allow the cutoff utility service to a manufactured home stand at the manufactured home stand and at the entrance of the utility service from the stand to the trunk line of the utility system. If overhead service lines are provided within the park, such lines shall be a minimum of 25 feet above the grade of interior streets and so placed that no wires extend over a manufactured home stand.

(3) Improvements required for manufactured home stands. Each manufactured home stand shall meet the following minimum requirements:

a. Interior street access. Each stand shall be provided with access frontage of at least 40 feet.

b. Garbage cans. Private service with dumpsters shall be required.

c. Electric power supply. The electric power supply will be in accordance with local code requirements.

d. Stand identification. A property and street number designation or other appropriate numbering device properly identifying each

manufactured home stand shall be placed at the interior side lot line at a point ten to 15 feet from the interior road system of the park.

Such device shall be a minimum of six inches in height.

(d) See also the manufactured homes section in chapter 3, Restrictions on Particular Uses of this development code.

History

The history line the source prints at the end of the section.

(Ord. No. 2021-10, § 1, 6-28-2021)

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:fort-oglethorpe/zoning/appendix-a-chapter-4-article-2-2.2@2026-03-26-ad69651965

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Fort Oglethorpe Zoning Ordinance, Sec. 2.2 (Appendix A, Chapter 4, Article 2). Specific requirements for R-4 zoning district | Georgia Commons