(a) All development entrances. All proposed subdivision developments (residential, nonresidential, and nonresidential single lot developments) where a new entrance is provided from an existing city road, shall construct deceleration lanes subject to the requirements of this section, and Standard Detail 206 "Subdivision Entrance Intersection."

The following requirements shall also apply to development entrances:

(b) Residential entrances. In addition to the requirements of subsection (a) above, the following shall also apply to residential subdivisions entrances:

(1) Access to every residential subdivision shall be provided over a public street.

Existing subdivisions with private streets can be continued without additional access to a public street, subject to subsection (2) below.

(2) All residential subdivisions resulting in the creation of 150 or more lots shall be provided with a minimum of two entrances. Where the property configuration prohibits or makes impractical the installation of two public access entrances, an alternative access may be approved or this provision may be waived by the director of public works for existing zoned property only. All property applying for rezoning that have less than the required number of entrances must receive approval from the city council.

(3) In the event an alternative second entrance is required, said entrance must be at least 20 feet wide with a 20-foot wide access easement and be constructed of all-weather surface. All alternative secondary access entrances and construction materials must be pre-approved by the director of public works and the director of building, planning and zoning.

(4) Any residential subdivision accessed by a city road shall conform to Standard Detail 206 "Subdivision Entrance Intersection."

(5) Access onto a state road shall meet existing GDOT requirements. Before the plans can be approved, a copy of the GDOT permit or GDOT letter of intent shall be submitted to the director of public works stating that a curb cut will be granted as long as the applicant meets all GDOT standards. The submitted construction plans must indicate by a note on the preliminary plat that the plans have been approved subject to all modifications or requirements placed upon the development by the

GDOT.

(6) Deceleration lane and taper length shall be based on the main roadway posted speed limit as follows in Table 7-D: Deceleration Lane and Taper Width. The director of public works may require residential subdivisions exceeding 200 or at his discretion below 200 lots to install longer deceleration lanes and/or a center turn lane. If the director of public works determines that the entrance onto a city roadway could result in a safety problem then the city may require the developer to present a traffic study to address any safety concerns.

Table 7-D: Deceleration Lane and Taper Width Main Road Speed Limit Deceleration Lane Length (feet) Transition Taper Length (feet) 55 mph 200 50 50 mph 150 40 45 mph 110 35 40 mph 90 30 35 mph or less 50 25

(7) The minimum pavement width of a deceleration lane shall be 12 feet, and the minimum turning radius shall conform with Standard Detail 206. The minimum pavement design for the proposed street shall be six inches/two inches/one and one-half inches or match the existing pavement specification, whichever is greater.

(8) Additional street right-of-way necessary for deceleration lanes shall be dedicated as needed, and as illustrated in Standard Detail 206 "Subdivision Entrance Intersection."

(9) The cross slope of any deceleration lane shall follow the crown or super elevation of the existing street.

(10) In cases involving rock cuts, deep fills or cuts, proximity to a floodplain, or other constraints to construction, the requirements for pavement widening for a full deceleration lane may be waived by the director of public works.

(11) Vertical faced curb and gutter or concrete extruded curbs are required through the radius, excluding the tapers.

(12) The developer shall be responsible for the costs of any utility relocation or catch basins that must be constructed.

(c) Non-residential entrances. In addition to the requirements of this section, the following shall also apply to non-residential project entrances:

(1) All nonresidential subdivisions or developments will install a full deceleration lane, offset radii and tapers.

(2) All driveways providing access to the street shall be designed as illustrated in Standard Detail 209 "Nonresidential Driveway on Existing Street Landing Requirements" and Standard Detail 210 "Nonresidential Driveway Landing Requirements on Existing Streets."

History

The history line the source prints at the end of the section.

(Ord. No. 2021-10, § 1, 6-28-2021)

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:fort-oglethorpe/zoning/appendix-a-chapter-7-article-3-3.4@2026-03-26-fb44e17961

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Fort Oglethorpe Zoning Ordinance, Sec. 3.4 (Appendix A, Chapter 7, Article 3). Development entrance requirements | Georgia Commons