--- title: Fort Oglethorpe Zoning Ordinance, Sec. 4.13 (Appendix A, Chapter 7, Article 4). Optional rigid pavements collection: local-codes id: local-code:fort-oglethorpe/zoning/appendix-a-chapter-7-article-4-4.13 cite_as: Fort Oglethorpe, Ga., Zoning Ordinance, Appendix A, Chapter 7, Article 4, § 4.13 canonical_url: https://georgiacommons.org/code/local/fort-oglethorpe/zoning/appendix-a-chapter-7-article-4-4.13 md_url: https://georgiacommons.org/code/local/fort-oglethorpe/zoning/appendix-a-chapter-7-article-4-4.13.md text_url: https://georgiacommons.org/code/local/fort-oglethorpe/zoning/appendix-a-chapter-7-article-4-4.13/text source_url: https://library.municode.com/ga/fort_oglethorpe/codes/code_of_ordinances date: 2026-03-26 status: active jurisdiction: city:fort-oglethorpe jurisdiction_name: Fort Oglethorpe place_fips: "1330956" corpus_version: local-codes-fort-oglethorpe-bb4b9cc35932 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/fort-oglethorpe/zoning/~appendix-a/~chapter-7/~article-4.md previous: https://georgiacommons.org/code/local/fort-oglethorpe/zoning/appendix-a-chapter-7-article-4-4.12.md next: https://georgiacommons.org/code/local/fort-oglethorpe/zoning/appendix-a-chapter-7-article-4-4.14.md index: https://georgiacommons.org/code/local/fort-oglethorpe.md branch: zoning edition: As published by Municode, current through 2026-03-26 edition_date_kind: current_through source_publisher: Municode version_id: local-code:fort-oglethorpe/zoning/appendix-a-chapter-7-article-4-4.13@2026-03-26-23065916d1 --- # Fort Oglethorpe Zoning Ordinance, Sec. 4.13 (Appendix A, Chapter 7, Article 4). Optional rigid pavements > As published by Municode, current through 2026-03-26 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Appendix A - UNIFIED DEVELOPMENT CODE / Chapter 7 - INFRASTRUCTURE IMPROVEMENTS / Article 4 - STREET CONSTRUCTION STANDARDS The developer may choose to construct (concrete) rigid pavements instead of flexible (asphalt) pavements. Rigid pavement shall be designed and constructed to meet the following requirements: (a) Grading. (1) The grading requirements shall be the same as section 4.1 above, except the requirements for liquid limit and plastic index are not applicable. (2) The soils shall have a minimum CBR of three. (b) Subgrade. The subgrade requirements shall be the same as section 4.3 above. (c) Base. (1) The base requirements shall be the same as section 4.5 above. (2) The base thickness shall be a minimum of four inches. (d) Concrete mix. (1) The concrete mix shall be designed to provide a 28-day compressive strength of 4,000 pounds per square inch with a four-inch (+1) slump and maximum water cement ration of 0.45. (2) An air entraining agent shall be added to achieve a five percent air content. (3) The concrete mix shall have a nominal maximum aggregate size of one and one-half inches. (e) Concrete design. (1) The concrete thickness shall be six inches. (2) Reinforcing is not required. (3) Control joints shall be spaced regularly in a square pattern as per the PCA recommendations. (4) A longitudinal joint shall be constructed along the centerline. Lateral joints shall be spaced the same as the lane width. (5) Joints shall be sealed using an approved joint sealer. The joint sealer shall be submitted to the geotechnical engineer for approval before installation. (f) Concrete placement. (1) Concrete placement shall be according to American Concrete Institute (ACI) 304 Recommended Practice for Measuring, Mixing, Transporting, and Placing Concrete. (2) Concrete shall be placed directly on the base. (3) The ambient temperature at the time of placement shall be at least 40 degrees F, and the forecast temperature in the first 24 hours after placement shall be at least 32 degrees. (4) No standing water or frozen base shall be present at the time of placement. (5) The concrete mix is expected to arrive at the site at the correct slump. If trucks arrive with a slump more than one inch below the specified slump, then a maximum of 20 gallons of water may be added, with the approval of the concrete supplier, to adjust the concrete slump. No water may be added after placement begins. If trucks arrive with a slump more than one inch above the specified slump, the truckload shall be rejected. (6) Concrete shall be placed within 90 minutes of the batch time. (g) Concrete protection and curing. (1) Freshly placed concrete shall be protected from premature drying and excessive cold or hot temperatures. ACI 306.1 for cold-weather protection and with ACI 305R for hot-weather protection shall be complied with. (2) Curing shall be accomplished in strict compliance with ACI 308. (h) Finish. The concrete finish shall provide a durable, smooth surface, free of irregularities, but skid-resistant (such as burlap drag or broom finish). ## History (Ord. No. 2021-10, § 1, 6-28-2021)