--- title: Fort Oglethorpe Zoning Ordinance, Sec. 4.7 (Appendix A, Chapter 7, Article 4). Binder collection: local-codes id: local-code:fort-oglethorpe/zoning/appendix-a-chapter-7-article-4-4.7 cite_as: Fort Oglethorpe, Ga., Zoning Ordinance, Appendix A, Chapter 7, Article 4, § 4.7 canonical_url: https://georgiacommons.org/code/local/fort-oglethorpe/zoning/appendix-a-chapter-7-article-4-4.7 md_url: https://georgiacommons.org/code/local/fort-oglethorpe/zoning/appendix-a-chapter-7-article-4-4.7.md text_url: https://georgiacommons.org/code/local/fort-oglethorpe/zoning/appendix-a-chapter-7-article-4-4.7/text source_url: https://library.municode.com/ga/fort_oglethorpe/codes/code_of_ordinances date: 2026-03-26 status: active jurisdiction: city:fort-oglethorpe jurisdiction_name: Fort Oglethorpe place_fips: "1330956" corpus_version: local-codes-fort-oglethorpe-3b41f36fb626 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/fort-oglethorpe/zoning/~appendix-a/~chapter-7/~article-4.md previous: https://georgiacommons.org/code/local/fort-oglethorpe/zoning/appendix-a-chapter-7-article-4-4.6.md next: https://georgiacommons.org/code/local/fort-oglethorpe/zoning/appendix-a-chapter-7-article-4-4.8.md index: https://georgiacommons.org/code/local/fort-oglethorpe.md branch: zoning edition: As published by Municode, current through 2026-03-26 edition_date_kind: current_through source_publisher: Municode version_id: local-code:fort-oglethorpe/zoning/appendix-a-chapter-7-article-4-4.7@2026-03-26-ac8f560ef5 --- # Fort Oglethorpe Zoning Ordinance, Sec. 4.7 (Appendix A, Chapter 7, Article 4). Binder > As published by Municode, current through 2026-03-26 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Appendix A - UNIFIED DEVELOPMENT CODE / Chapter 7 - INFRASTRUCTURE IMPROVEMENTS / Article 4 - STREET CONSTRUCTION STANDARDS (a) Contractors must contact the geotechnical engineer prior to beginning the binder course installation. This is imperative or the work may not be accepted. (b) The binder asphalt shall be placed over the prime coat. (1) The geotechnical engineer will test the thickness and compaction by obtaining cores every 500 feet, or a minimum of three cores. (2) If any area does not meet the minimum thickness or compaction requirements, additional cores will be taken at 100-foot intervals until two consecutive cores meet the requirements. Areas that do not meet the requirements shall be removed and replaced. As an option, at the developer's discretion, the geotechnical engineer can be present during construction to check the laydown thickness and temperature of the asphalt and to conduct nuclear density tests after compaction. In this case, coring will be reduced to three cores or one every 2,000 feet. In any case, a minimum of three cores will be required. (c) The binder asphalt shall meet the requirements of sections 400, 402, and 828 of the Georgia Department of Transportation "Standard Specifications Construction of Transportation Systems" (latest edition). The minimum binder design thickness shall be two inches. (d) Binder thickness tolerances. (1) The average thickness of the binder shall be greater than or equal to the design thickness, with no individual test more than one-quarter-inch less than the design thickness. (2) Areas deficient in thickness shall be evaluated by additional coring at 100-foot intervals to determine the area of deficient thickness. The deficiency may be corrected by increasing the thickness of the surface asphalt. ## History (Ord. No. 2021-10, § 1, 6-28-2021)