Sec. 90-262. Buffers.

About this text

  • As published by Municode, current through 2026-06
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

{a) Buffers are required to achieve a visual barrier between properties of different use.

However, existing or proposed plant material located within a buffer cannot be applied toward density requirements of a site. The area of a buffer can be subtracted from the total area of a site when calculating density requirements.

(b) Buffer widths shall be as indicated in this Ordinance or as allowed by variance or zoning conditions. Buffer plantings can be located within the setback limits required by zoning. In the case where buffer zones are wider than setback requirements, the buffer zones supersede.

Unless otherwise directed by zoning or this Ordinance, buffers shall remain undisturbed.

When existing vegetation exists in a buffer it shall be protected from encroachment during construction.

(c) Where buffers are void of existing vegetation adequate enough to provide a visual barrier or the buffers have been violated, the owner/developer is responsible for replanting.

Refer to the buffer examples below for a formula based on the square footage of the entire buffer or portion thereof that is void of adequate material.

( d) Adequacy of the undisturbed buffers to provide a visual barrier will be determined by the city based on visual analysis and the types of existing plant material and reserves the right to require remedial evergreen understory planting if it is determined that the undisturbed buffer does not provide an adequate visual buffer.

(e) The city encourages the control or elimination of invasive plant material including Chinese Privet, Kudzu, Wisteria, etc. Selective clearing in buffers to remove noxious or invasive plant material and the methods of removal will require the approval of the city.

Selective buffer clearing will be reviewed on a case by case basis. Removal of material may require the replanting to buffer standards if the buffer is over cleared.

(f) Buffer zones shall be provided as follows:

GENERAL ZONING CLASSIFICATION

GENERAL ZONING CLASSIFICATION

Single Family Multi-Family Commercial Institutional Office Industrial Mixed-Use Single Family Residential X 10' 25' 10' 25' 500' 10' Multi-Family Residential 10' X 25' 10' 25' 300' 10' Commercial 25' 25' X 10' 10' 100' 10' Institutional 10' 10' 10' X 10' 100' 10' Office 25' 25' 10' 10' X 100' 10' Industrial 500' 300' 100' 100' 100' X 300' Mixed-Use 10' 10' 10' 10' 10' 100' X For purposes of interpreting this Code Section, contiguous properties include properties which do not directly abut each other, but would directly abut each other if not separated by the width of (1) any canal, creek or river, or (2) any right-of-way of a railroad or other public service corporation.

Type I Buffer shall be applied to all buffers less than 50 feet wide:

The following plant material shall be provided per 1,000 square foot of buffer area to be vegetated:

1 Shade/Canopy trees 5 Evergreen understory trees 15 large evergreen shrubs

EXAMPLE 1—50 FOOT BUFFER

1,750 square foot buffer area

1.75 x 1 tree = 2 trees

1.75 x 5 understory trees = 9 trees

1.75 x 15 large shrubs = 26 shrubs Round up when quantity exceeds .5.

Type II Buffer shall be applied to all buffers 50 feet wide and greater:

The following plant material shall be provided per 1,000 square foot of buffer area to be vegetated:

1 Shade/canopy trees 5 Evergreen understory trees 15 large evergreen shrubs

EXAMPLE 2—100 FOOT BUFFER

3,500 square foot buffer area

3.5 x 1 tree = 4 trees

3.5 x 5 Understory trees = 18 trees

3.5 x 15 Large shrubs = 53 shrubs Round up when quantity exceeds .5 Minimum tree sizes upon installation are as follows:

Canopy/shade tree size: 2 inch caliper Understory evergreen: 6 feet high Large shrub size 24 inches high In addition to the material required for the Type II Buffer, a continuous eight-foot-high opaque screening fence shall be installed on the outside of the buffer along the entire buffer when no effective vegetation exists. The screening fence shall be ten feet high for intensive industrial uses.

The screening fence shall be constructed of wood, brick, stone, masonry units, or other similar material, excluding tin, plastic, doors, vinyl, woven wire, salvage material or other similar products. Property owner is responsible for installing access gates along with the fence in order to maintain the buffer.

The planning commission may make recommendations for the modification of buffer requirements at the time of development plan review, provided that the modification would be consistent with the intent of this code section that such modification would not adversely affect land use compatibility or the public interest, and that the subject property or buffer complies with one or more of the criteria below.

(1) The required buffer is parallel and adjacent to an existing utility or drainage easement of at least 100 feet in width.

(2) An existing specimen tree, buffer on an adjacent property, or other physical impediment physically prevents strict adherence to this section.

(3) Redevelopment of the property requires a buffer to be added, but a building, stormwater facility, or utilities exists where the buffer is required.

(4) The required buffer area would occupy more than 30 percent of the developable area of the site.

(5) The property is zoned industrial (I-1 or I-2) but will be developed for a use which is not classified as an intensive industrial use as specified in code section 90-5.

Any modification shall minimize the deviation allowed from the required standard. The planning commission shall not recommend the elimination of a required screening fencing for a Type II buffer.

History

The history line the source prints at the end of the section.

(Ord. of 1-22-08, § 1; Ord. No. 2023-05, § 1, 1-17-23; Ord. No. 2025-12, § 6, 8-18-25)

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.

Version local-code:garden-city/zoning/90-262@2026-06-16a7e90df2

The assistant can say what this section says in this edition, quoting it and linking to it. It will not apply the law to your situation, and nothing here is legal advice.

Garden City Zoning Ordinance, Sec. 90-262. Buffers | Georgia Commons