Sec. 62-504. Anchoring and support systems.

About this text

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

(a) Each mobile home shall have provisions for support and anchoring systems, which when properly designed and installed, will resist overturning and lateral movement of the mobile home.

(b) The provisions made for anchoring systems shall be based on the following design criteria for single-wide mobile homes:

(1) The minimum number of ties shall be in accordance with Table 2 at the end of this article.

(2) Ties shall be as evenly spaced as practicable along the length of the mobile home with not more than eight feet open-end spacing on each end.

(3) When continuous straps are provided as vertical ties, such ties shall be positioned at rafters and studs. Where a vertical tie and diagonal tie are located at the same place, both ties may be connected to a single ground anchor, provided that the anchor used is capable of carrying both loadings.

(4) Add-on sections of expandable mobile homes shall have provisions for vertical ties at the exposed ends.

(c) Double-wide mobile homes require only the diagonal ties specified in Table 2 at the end of this article. These shall be placed along the outer side walls.

(d) Protection shall be provided at sharp corners where the anchoring system requires the use of external cables or straps. Protection shall also be provided to minimize damage to roofing or siding by the cable or straps.

(e) Anchoring equipment shall be capable of resisting an allowable working load equal to or exceeding 3,150 pounds and shall be capable of withstanding a 50 percent overload (4,725 pounds total) without failure of either the anchoring equipment or the attachment point on the mobile home.

(f) Anchoring exposed to weathering shall have a resistance to weather deterioration at least equivalent to that provided by a coating of zinc on steel of not less than 0.30 ounces per square foot of surface coated.

(g) The provisions of this section shall be followed except when the support and anchoring systems are designed by a registered professional engineer or architect, in which the circumstances described in subsections (b)(1) and (c) of this section are not applicable.

Table 2

NUMBER OF TIES REQUIRED PER SIDE OF SINGLE-WIDE AND DOUBLE-WIDE1

MOBILE HOMES

Length of Mobile Home2 (1) Number of Vertical Ties (2) Number of Diagonal Ties3 (3) 32 to 40 2 4

41 to 46 2 4 Length of Mobile Home2 (1) Number of Vertical Ties (2) Number of Diagonal Ties3 (3) 47 to 49 2 5

50 to 54 3 5 55 to 58 3 5 59 to 64 3 6 65 to 70 3 6 71 to 73 3 7 74 to 84 4 7 1 Double-wide mobile homes require only the diagonal tie specified in column 3, and these shall be placed along the outer sidewalls.

2 Length of the mobile home length excluding the drawbar.

3 Diagonal ties in this method shall deviate at least 40 degrees from a vertical direction.

Source: Federal Register "Federal Mobile Homes-Construction and Safety Standards," Vol.

40, No. 123.

History

The history line the source prints at the end of the section.

(Res. No. 24-10, att., 9-19-2023; Res. No. 25-21, 1-7-2025)