3.9.3. Commercial Lighting Requirements
About this text
- As posted on the county's website, retrieved 2026-11-23
A. Off-site light spillover must not produce a glare which creates a safety or traffic hazard.
B. All lighting fixtures designed or placed so as to illuminate any portion of a site must meet the following requirements:
1. All lighting fixtures (luminaries) must be cutoff luminaries whose source is completely concealed with an opaque housing capable of shielding the light source from direct view from any adjoining residential property or public right-of-way. Fixtures shall be recessed in the opaque housing. Drop dish refractors are prohibited. Decorative light fixtures with a maximum of 1,500 lumens are not required to be cutoff luminaries with a shielded light source.
2. Fixtures must be mounted so that the cone of the light is completely within the property lines of the property on which the fixture has been placed. The maximum mounting height for a pole is 35 feet.
3. Lighting levels at adjoining residential property boundaries may not exceed two (2) footcandles as measured at any height and with any orientation of the measuring device at any location along the property line.
4. All site lighting, except as required by the swimming pool code, must be designed so that the maximum levels of illumination (measured in footcandles) at any one point conforms to Table 3.9.3.B.
Table 3.9.3.B. Illumination Levels Location of Lighting Maximum Footcandles Non-residential and Multifamily Parking Lots 10.0 Service station canopy 50.0 Parking garage 60.0 Landscaped Areas 5.0 Residential Uses 5.0
C. Illumination levels in the table above may not exceed the calculated value and must be derived using only the area of the site included to receive illumination. Points of measure, in footcandles at points located on a 10-foot center grid, may not include the area of the building or areas which do not lend themselves to pedestrian traffic.
D. A light meter sensor must be read at ground level or the established grade in a horizontal position.
Readings must be taken only after the light source has been exposed long enough to provide a constant reading. Measurements must be taken after dark with the light sources to be measured on and subsequently off. The difference between the two readings must be compared to the permitted illumination level for each lighting zone.
E. Strings of lights or similar accent lighting may be installed on trees, on landscaping, and on buildings below the roofline
F. Flag poles may be illuminated by fully-shielded spotlight light fixtures, or by fixtures that do not create off-site glare or light spillover above the established limits.