Gordon County · Zoning Ordinance
Chapter 4 - SITE DESIGN STANDARDS
4.02.01. Site Design Standards for the New Echota Overlay District
About this text
- As published by Municode, current through 2024-03-19
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
A. Description. The New Echota Overlay district shall be defined as all property east of Interstate 75 abutting or adjacent to State Highway 225, Craigtown Road, and Newtown Church Road as designated on the Gordon County Official Zoning Map.
B. Generally.
1. The purpose of the New Echota Overlay District is to protect the historic setting and viewsheds of the New Echota Historic Site and the unique experience enjoyed by residents and visitors by ensuring that new development in the district will complement rather than detract from the historic value of the site and surrounding area and will respect the district's rural character, natural features and significance as the former Cherokee Capital and Trail of Tears site and round-up route.
2. This section establishes standards that apply to any new development on any lot or portion thereof that is in whole or in part contained within the boundaries of the New Echota Overlay District. These standards and criteria shall be applied in addition to the site design standards of the underlying zoning district and all other applicable standards of this ULDC. In the event of a conflict between the requirements of the New Echota Overlay District and the underlying zoning district or other applicable standards of this ULDC, the stricter standard shall apply.
3. The provisions of these standards do not apply to:
a. Farm or agricultural-related structures;
b. Single-family dwellings and manufactured homes on an existing lot of record;
c. Developments existing on the effective date of this section, provided that expansions or additions to existing development as defined in Section 4.02.01(C)(3) on or after the effective date of this section shall be subject to compliance with these regulations.
4. The provisions of these standards do not require any change in the construction, or intended use of any structure, the construction or alteration of which was begun prior to the effective date of this section and which is pursuant to a valid building permit.
5. Nothing contained herein shall be construed to replace or supersede existing zoning classifications of properties within the New Echota Overlay District. It is, however, the intent of this section for all properties developed in the district to meet all of the standards outlined herein. It is further the intent of this section that previously zoned properties shall develop using the standards outlined in this section.
C. The following standards shall apply within the New Echota Overlay District:
1. General Site Design
a. Preservation of Site Features. Significant site features such as existing vegetation, natural or historic manmade ground forms, and significant view corridors shall be identified and incorporated into development plans. Clearing of native vegetation shall be limited to that required for the provision of essential purposes (e.g. access, building, utility crossing, sewage disposal).
b. Site Grading. Developments shall be designed to fit the existing contours and landform of the site and to minimize the amount of excavation and moved earth to minimize visual impacts, erosion, and destruction of historic, manmade earthworks and archaeological resources.
i. Where cut and fill is necessary, it shall be balanced.
ii. When grading must occur, it shall blend with the natural landform as much as possible.
iii. Abrupt or unnatural-appearing grading shall be prohibited, including the creation of harsh, easily eroded banks and cuts.
iv. The height and length of retaining walls shall be minimized and screened with appropriate landscaping. The use of terracing or walls consisting of natural materials that blend with the vegetation or abutting landscaping features shall be required in areas that are visible from the public right-of-way. Tall or prominent, smooth-faced concrete retaining walls are prohibited in areas that are visible from the public right-of-way.
v. Disturbed areas that are not used for roads, buildings or other auxiliary uses shall be replanted.
2. Tree Protection. The removal of trees incidental to the development of land or to the marketing of land for development shall be done in conformance with the following provisions:
a. Cutting and Clearing. All reasonable efforts shall be made to minimize cutting or clearing of trees and other woody plants.
i. Removal of trees over five (5) inches in caliper shall be prohibited, where possible, by appropriately siting buildings, parking lots or entrance/exit drives.
ii. Residential and mixed-use developments are required to retain twenty (20) percent of the site as woodland.
iii. Commercial, office, institutional and industrial developments are required to retain fifteen (15) percent of woodland on the site.
iv. If the site is not currently forested, or only partially forested, the property owner/developer shall be required to plant trees to meet this requirement.
b. Replacement Trees. Where replacement or new trees are necessary to meet the above requirements, Sections 4.07.04(B)(6)—(8) of this ULDC shall be followed in addition to the following provisions:
i. Trees shall be compatible with the site ecologically and in terms of space requirements.
ii. Trees shall have potential for size and quality comparable to those removed.
iii. No one (1) genus shall comprise more than thirty (30) percent of the replacement trees.
c. Protection of Trees During Construction. Tree protection devices shall be installed prior to the issuance of a land use permit for any clearing and/or grading. All reasonable efforts to protect retained trees during the construction process shall be made, including, but not limited to, the following measures:
i. Placing protective barriers (chain link fencing, orange laminated plastic fencing supported by posts, rail fencing, or other equivalent restraining material) around trees, including the trees' critical root zone (CRZ), which for the purpose of this section shall be defined as the minimum area beneath a tree which must be left undisturbed in order to preserve a sufficient root mass to give a tree a reasonable chance of survival. The protective barrier shall be located at the outer CRZ or the drip line, whichever is greater. For the purpose of this section the drip line shall be defined as line on the ground of points projected vertically from the ends of farthest branches of the tree;
ii. Marking the required protective barriers with "tree save area" signs;
iii. Not grading, excavating, or locating utilities within the trees' CRZ;
iv. Maintaining the CRZ as a pervious surface;
v. Maintaining the topsoil in the CRZ and preventing siltation; and vi. Maintaining tree protection devices in functioning condition throughout all phases of development, subject to inspection by Gordon County Building Inspector.
d. Buffers. All buffers with existing trees that may be required by this ULDC or provided by a development shall be delineated on plans as tree save areas.
e. Exempt Uses. The provisions of this section shall not apply to agricultural uses, to single-family dwellings and manufactured homes on an existing lot of record, and to new single-lot residential development not part of a residential subdivision.
3. Commercial Development. The following standards shall apply to all new development, with the exception of development in a Rural Zoning District or a Residential Zoning District. In addition, these standards shall apply to any existing developed lot, parcel, or tract of land not located in a Rural Zoning District or a Residential Zoning District for which a sign or building permit is required.
These standards shall be waived for any renovation of or addition to an existing building which the cost thereof is less than fifty (50) percent of the ad valorem tax value as established by the current digest at the time the proposed renovations and/or building additions begin or are contemplated.
a. General Appearance Standards
i. A building's size, scale, massing, fenestration, rhythm, setback, materials and context shall be compatible with the character of the district.
ii. Exterior building features visible from a public right-of-way shall be organized to allow diversity in architectural design while incorporating traditional elements of commercial building forms such as canopies or awnings, storefront windows, cornice lines atop building facades, structural columns, facade recesses and projections, traditional roofs or parapet walls, varied parapet height, or traditional or varied arrangement of exterior building materials.
iii. Multiple buildings on the same site shall be designed to create a cohesive visual relationship between the buildings.
b. Size and Scale. The relationship of a building to the project site (building "size") and to buildings around it ("scale") shall be addressed as part of the design process. The following provisions shall apply:
i. Maximum building height for a principal building shall be forty (40) feet, measured from the bottom of the base of the structure at ground level to the highest point of such structure.
ii. The height of proposed buildings and adjacent structures shall be compatible.
c. Massing. The relationship of a building's various parts to each other ("massing") shall reflect a human scale. For illustrative purposes, building elements that contribute to this desired scale include, but are not limited to, prominent entry features, inset windows or the use of cornice lines.
d. Fenestration. The placement of doors and windows ("fenestration") shall create a balanced facade with traditional proportions and limited blank wall space, in accordance with the following provisions:
i. Not less than sixty (60) percent of the total surface area of the front facade shall be public entrances and windows.
ii. Blank facades visible from any public right-of-way are prohibited. Up to eighty (80) percent of the length of a facade may be exempt from this standard if oriented toward a loading or service area or if visible from, but not facing, a public right-of-way.
iii. Windows shall be transparent. Mirrored, smoked or tinted glass is prohibited.
e. Rhythm. The relationship of fenestration and facade recesses and projections ("rhythm") shall add visual interest and prevent long or continuous building walls. The following provision shall also apply:
i. Building surfaces greater than two (2) stories in height or fifty (50) feet in width shall include changes in wall plane (i.e. recesses and projections).
Figure 1. Recesses and projections along a building facade Source: Georgia Department of Community Affairs
f. Setback. Building setbacks shall meet the minimum standards required by this ULDC.
g. Materials. Exterior building materials shall meet the provisions identified below. Materials not identified shall be prohibited.
i. Exterior wall surfaces shall be unpainted brick, stone, architectural or rusticated cement masonry units to imitate the look of stone, cement fiber board or other building code approved composition lapboard siding.
ii. Facades facing a public right-of-way shall be a minimum of eighty (80) percent brick and/or stone.
iii. Side facades shall be a minimum of fifty (50) percent brick and/or stone.
iv. Rear facades not visible from a public right-of-way shall be permitted to consist of the materials identified above, in addition to natural or synthetic stucco. The color of the rear facade shall coordinate with the remaining facades of the building.
v. A minimum of twenty (20) percent of a facade visible from a public right-of-way shall be a physical building material change. This change may include a change in color of a permitted building material, a change in permitted building materials, or a change in assembly of permitted building materials.
vi. Framing of windows, doors and storefronts shall be constructed with wood or aluminum casings of no less than 1.5 inches in width, a profile depth of no less than one (1) inch, and frame or pier divisions between windows having a width of no less than five (5) inches. All windows must have a sill with a profile no less than five (5) inches. The portion of the facade below display windows ("bulkhead") should match exterior cladding materials or be of framed wood.
vii. Rigid canopies or all fabric (non-vinyl), shed-style awnings are permitted.
Awnings may be sideless construction. Valances on all canopy and awnings shall be fabric (non-vinyl) and shall be no less than eight (8) inches in width. Awnings shall project from the building facade no less than 5.5 feet, and the bottom edge shall be no less than 7.5 feet above the sidewalk.
Canopies and awnings shall only be as wide as each storefront and shall not cross major vertical building elements, such as building piers or pilasters. Back-lit canopies or awnings are prohibited.
viii.Roof materials, when visible from the public right-of-way, shall be standing seam, stamped metal shingle or faux architectural composite shingle.
h. Building Color
i. Facade colors shall be low reflectance, and neutral or earth-tone colors.
High-intensity colors, metallic colors, black, fluorescent or neon colors are prohibited.
i. Roof Form. Gable, hip, pyramid or flat roofs shall be required on any principal building, in accordance with the following provisions:
i. Sloped roofs shall meet in a clear roof line or peak.
ii. Gable and pyramid roofs shall have a minimum slope of 6/12.
iii. Hip roofs shall have a minimum slope of 4/12.
iv. Gable, pyramid and hip roofs shall provide a minimum overhang or eave of twelve (12) inches beyond the building wall.
v. Flat roofs may be permitted with the use of a parapet wall having a minimum height of three (3) feet.
vi. Shed roofs shall be prohibited with the exception that such roofs may be allowed on incidental rooms or building wings attached to the principal structure. Said roofs shall have a minimum slope of 4/12, shall provide a minimum overhang of twelve (12) inches beyond the building wall, and shall not exceed thirty (30) percent of the total roof area.
vii. Other roof types not identified in this section are prohibited.
viii.Roof materials shall be in accordance with Section 4.02.01(C)(3)(g)(viii).
Figure 2. Appropriate Roof Forms Source: The Latest Illustrated Book of Development Definitions (Moskowitz and Lindbloom, 2004); MACTEC
j. Signage
i. Single Building on a Lot. A combination of one (1) wall and one (1) monument sign is permitted for businesses and for public/institutional facilities. A wall sign shall not exceed two (2) square feet per linear foot of the building facade, with the total sign area not to exceed one hundred fifty
(150) square feet. Except for double frontage lots no single building or unit shall be permitted more than one (1) wall sign. No monument sign, which shall be defined as the sign area and the base combined, shall have a height greater than six (6) feet, or an area greater than thirty-five (35) square feet per side. A monument sign shall not be located within ten (10) feet of a street right-of-way or within fifty (50) feet of any other sign, structure or building. Monument signs shall be mounted on a base constructed of the same material as the exterior building material of the principal use. If the principal use is constructed of a material not permitted in this section, the sign base shall be constructed of a material identified as permissible for front building facades in Section 4.02.01(C)(3)(g). No air space shall be visible within or between any portion of the sign display area and sign structure. Permitted signs shall not be internally illuminated.
ii. Two (2) or More Businesses. Two (2) or more businesses consisting of individual buildings or units which are adjacent or abutting one another on a lot shall be permitted to erect one (1) shared monument sign. No monument sign, which shall be defined as the sign area and the base combined, shall have an area greater than forty-five (45) square feet or a height greater than six (6) feet. No portion of the sign shall include an area for changeable letters. One tenant directory sign is permitted per entrance.
Directory signs shall not be designed or placed so as to be read from a public road. Each tenant shall be allowed up to one hundred eight (108) square inches of signage. Each panel on a directory sign shall be of the same size, color, and front. Each building or unit with a separate entrance, not accessible by other tenants, shall be permitted one (1) wall sign with a maximum area of five (5) percent of the building facade which it is mounted upon, but not to exceed one hundred fifty (150) square feet.
Additional wall signs are not allowed for multiple facade frontages. If two
(2) or more tenants, as in the case of an office building, share an entrance to a building, wall signs on the exterior of the building are not permitted.
Permitted signs shall not be internally illuminated.
Figure 3A. Appropriate Sign Types Source: Planning and Urban Design Standards (APA, 2004); MACTEC iii. Use of Awnings and Windows. The use of awnings and windows for business signs shall be reserved for secondary signs, which for the purpose of this section are defined as signs that are secondary in nature to, and smaller in size than, primary wall and monument signs. Each business shall be permitted to use either an awning or window space for secondary sign use. The use of an awning for signage shall be limited to the valance.
Window signs shall be limited to the ground floor, and no window shall be covered by more than thirty (30) percent of signage. Window signs may be painted on the inside of the window. Hand written signs shall not be permitted. A maximum of twenty (20) percent of the allowable square footage of space for a wall sign shall be permitted for a secondary sign.
Figure 3B. Appropriate Sign Types Source: MACTEC iv. Prohibited Signs. In addition to the prohibited signs identified in Section
5.04.02 of this ULDC, banners, rooftop signs, freestanding pole signs, electronic or changeable message/copy signs, flashing, blinking, rotating, fluctuating, or otherwise animated signs, streamers or pennants, and outdoor advertising signs (billboards) are prohibited.
k. Sign Landscaping. Sign landscaping shall conform to Sections 4.07.03, 4.07.04 and 4.07.05 of this ULDC in addition to the following provisions:
i. Monument signs shall have a landscaped area at the base of the sign which is a minimum of three (3) feet wide on each side, and at least the length of the sign. The sign area landscaping shall consist of a dense vegetative ground cover or a minimum one (1) shrub per three (3) linear feet of landscaped area on each side of the sign. Landscaped areas containing shrubs greater than three (3) feet in height shall be located a minimum of twenty (20) feet from the intersection of two (2) street rights-of-way lines, or the intersection of a street right-of-way line with a driveway pavement edge.
l. Site Landscaping. Site landscaping shall conform to Sections 4.07.03, 4.07.04 and 4.07.05 of this ULDC in addition to the following provisions:
i. A landscaped buffer having a minimum width of fifteen (15) feet is required along the entire length of any property line abutting a public right-of-way, residential uses or any residential or rural zoning district.
There shall be one (1) tree for every thirty (30) feet of lot frontage along said property line.
ii. Tree placement shall follow the guidelines established in Table 4.02.01(C)(3)(1) Guidelines to Avoid Conflicts with Infrastructure.
Table 4.02.01(C)(3)(1) Guidelines to Avoid Conflicts with Infrastructure
MATURE SIZE
LARGE
50—70 FT.
MEDIUM
30—40 FT.
SMALL
15—20 FT.
EVERGREEN
40—50 FT.
Minimum Width of Tree Lawn (area required for planting) 8 Feet 5 Feet 3 Feet Yards Only Spacing Between 60 Feet 40 Feet 20 Feet 30 Feet Overhead Utilities Do Not Plant Acceptable Acceptable Do Not Plant Distance from Signs,
Utility Poles, Driveways, Fire Hydrants 10 Feet 10 Feet 10 Feet 30 Feet Distance From Intersection 30 Feet 30 Feet 30 Feet 30 Feet Distance From Underground Utilities 5 Feet 5 Feet 5 Feet 5 Feet
m. Site Lighting. Exterior lighting shall be architecturally compatible with the building style, material and colors and shall be directed onto the site.
i. Full cut-off light fixtures are required to direct light downward, and in no case shall such lighting project into the right-of-way or neighboring properties.
ii. Pedestrian scaled accent lighting to highlight building, landscape and sign features is permitted.
iii. Roof lighting, down-lighting washing the building walls, illuminated awnings or canopies, searchlights, laser lights, and flashing, moving, revolving, flickering, strobe lights, or any lights that change intensity or color are prohibited.
iv. Fixture mounting height in parking lots or service areas shall not exceed twenty (20) feet in height.
v. Low, bollard-type fixtures no greater than four (4) feet in height are encouraged as pedestrian-area lighting.
n. Fencing and Walls. In addition to meeting the provisions of Section 5.02.03 of this ULDC, the following provisions apply:
i. The design and materials of fences and walls shall be compatible with the architecture of the main building(s).
ii. Where permitted, fences shall be located in side and rear yards only, with the exception of property in a rural zoning district that is not within a platted subdivision, whereby fencing is permissible in accordance with Table 5.02.03(B) of this ULDC.
iii. Where chain link is permitted, it shall be vinyl coated (black or green in color).
iv. Walls along a public right-of-way are prohibited, except for low-lying decorative stone walls that do not impair viewsheds or walls that are needed for slope stabilization. Walls shall consist of natural materials and shall only be of those colors that blend with the vegetation or abutting landscape features.
o. Parking
i. Required off-street parking and loading areas shall be located to the rear of a principal building.
ii. Parking lots shall have a landscaped perimeter in accordance with Section 4.07.05(B) of this ULDC.
iii. A minimum of five (5) percent of the total parking lot area shall consist of internal landscaping.
iv. Parking lots with twenty (20) or more parking spaces shall provide interior landscaping in accordance with Section 4.07.05(C) of this ULDC.
p. Access
i. The entire parcel, rather than simply a particular project, shall be considered in formulating and approving access plans.
ii. Interparcel site access, for pedestrians as well as vehicles, shall be provided to adjacent properties when land uses are compatible.
iii. Common access easements for shared driveways along state highways and busy streets are strongly encouraged.
Figure 4. Interparcel access through linked parking lots at the rear of buildings Source: Rural by Design (Arendt, 1994)
q. Utilities
i. All electrical, cable, telephone and other such services shall be installed underground.
ii. All transformers and other facilities and equipment, including telecommunications equipment, meters and meter boxes located on the ground shall be placed to the rear of the principal building and shall be screened from view from the public right-of-way, residential uses, or any residential or rural zoning district by one hundred (100) percent opaque fencing through the use of pressure treated, natural wood fencing or brick or stone walls with landscape screening and/or, the use of an earthen berm. Required landscaping shall consist of shrub plantings three (3) feet to five (5) feet in height and evergreen plantings five (5) feet to eight (8) feet in height that are designed and installed to provide a visually impervious screen within two (2) years of planting.
iii. HVAC equipment and satellite dishes may be located on the roof of a principal building if said equipment is screened from view on all four (4) sides by architectural features such as the building roof, a parapet wall, or the building cornice integrated with the design of the building.
Figure 5. Roof-top equipment is screened from view on all four sides Source: City of San Juan Capistrano (CA) Design Guidelines
r. Dumpsters. In addition to meeting the provisions of Section 5.02.05 of this ULDC, the following provisions shall apply:
i. Screening materials are required to be one hundred (100) percent opaque, pressure treated, natural wood fencing or brick or stone walls with landscaping to minimize the appearance from the public right-of-way, any residential use or any residential or rural zoning district.
ii. Required landscaping shall consist of shrub plantings three (3) feet to five feet (5) in height and evergreen plantings five (5) feet to eight (8) feet in height designed and installed to provide a visually impervious screen within two (2) years of planting.
iii. Dumpsters are encouraged to be integrated into the mass of the principal building.
iv. Dumpsters shall not be located within fifty (50) feet of any residential use.
s. Loading Areas. Loading docks and areas shall be located to the rear of a principal building and screened from view of any public right-of-way, residential use or any residential or rural zoning district with landscape screening by a continuous planting of evergreen plantings five (5) feet to eight (8) feet in height that are designed and installed to provide a visually impervious screen within two (2) years of planting, and/or the use of an earthen berm no less than five (5) feet in height.
t. Other Accessory Site Features. Other accessory site features located on the ground shall be located to the rear of a principal building and shall be screened from view of any public right-of-way, residential use or any residential or rural zoning district by a one hundred (100) percent opaque, minimum six (6) feet high, pressure treated natural wood fence, landscaped berms and/or landscape screening with plantings that will reach a minimum height of six (6) feet within two (2) years of planting.
u. Service Stations. Where service stations are permitted the following standards shall apply in addition to other applicable provisions of this section:
i. Fuel pumps and car washes shall be located to the rear of the principal building. If a car wash is incorporated into a project, the car wash opening shall be sited so that it is not directly visible as the primary view from the street into the project site.
ii. The design elements of the all structures on the site, including the principal building, canopies, cashier's booth, or car wash facility shall have consistent architectural detail and design elements to provide a cohesive project site. The overall design of the facility shall be aesthetically compatible with the surroundings.
iii. All station amenities such as lighting fixtures, trash receptacles, and other features shall be coordinated in design with the building and the district.
iv. Striping, neon, and illuminated panels are not permitted on buildings or canopies.
v. All fuel canopy supports shall be clad in brick masonry construction or wood, with the exception that a maximum of twenty-five (25) percent of the cladding may be constructed of architectural concrete masonry units.
Standard concrete block canopy and supports shall not be permitted.
vi. The cladding of the columns shall be proportioned to the height and scale of the canopy.
vii. All canopy downspouts and related hardware shall be integrated into the canopy structure.
viii.The canopy structure shall relate to the main component of the building with respect to materials, massing, color, roof structure and overall design.
ix. Lighting luminaries mounted under the canopy structures shall be shielded such that the lamp source is not visible and glare is not created.
v. Drive-thru Facilities
i. Drive-thrus are limited to one (1) window or may only have one (1) drive-thru lane, with the exception of banks, which may have two (2) drive-thru lanes.
ii. Drive-thru facilities and stacking lanes, when adjacent to any public right-of-way, residential use or residential or rural zoning district shall be obscured from view by an earthen berm and/or landscape screening by a continuous planting of evergreen plantings five (5) feet to eight (8) feet in height that are designed and installed to provide a visually impervious screen within two (2) years of planting.
4. Residential Uses
a. Notwithstanding other land development regulations to the contrary, the use of conservation subdivision development in accordance with Section 4.05.00 of this ULDC is mandatory as a use by right in all residential developments in this district.
b. Entrance signs to a residential development shall meet the standards for monument signs in accordance with Section 4.02.01(C)(3)(j)(i).
Figure 6. Conventional subdivision design (left) and conservation subdivision design (right), which maximizes open space and protects existing vegetation, and natural and historic features
Source: Rural by Design (Arendt, 1994)
5. Prohibited Uses. The following uses are prohibited in the district:
a. Outdoor storage for building supply and vehicle parts/accessories visible from the public right-of-way;
b. Flea markets or similar outdoor or indoor/outdoor sales complexes;
c. Outdoor arenas, rodeo grounds, livestock auction facilities, race tracks (auto, dog, go-kart, horse, motorcycle), outdoor shooting and firing ranges and similar activities (excludes hunting on private property);
d. Storage yards for equipment, machinery and supplies for building and trades contractors, garbage haulers;
e. Vehicle sales, rental, service, and repair including truck stops, body shops, road services, car washes that stand alone, and the sales, rental and repair or new or used automobiles, boats, buses, farm equipment, motorcycles, trucks, recreational vehicles, and mobile homes;
f. Salvage yards and impound lots;
g. Outdoor play equipment/play grounds visible from the public right-of-way;
h. Industrial uses;
i. Telecommunication towers (includes cell towers); and
j. Adult entertainment establishments, including spas.
6. Design Review Application Process
a. Review of proposed development in the New Echota Overlay District, with the exception of development in Rural or Residential Zoning Districts, is required prior to issuance of applicable permits. A review panel consisting of the Gordon County Historic Preservation Commission (HPC) and the Planning Director or design shall accomplish such reviews. No review and approval of the Board of Commissioners or the Planning Commission shall be required. The Zoning Administrator shall be responsible for distributing all required application materials to each member of the review panel. Incompletion applications shall not be accepted. The review panel will meet monthly at a regularly scheduled meeting of the (HPC). No permit shall be issued prior to approval by the review panel. The following procedures shall apply to the review process:
i. Prior to the formal submittal of a design plan, the applicant is encouraged to meet with the Planning Director or designee for a review of the location, scope and nature of the proposed project. No preliminary plans, drawings, sketches or concept plans reviewed informally, in writing, or otherwise shall confer any development rights under this section.
ii. Seven (7) copies of design plans shall be submitted at least fourteen (14) days prior to the HPC meeting at which official review is requested.
iii. Each design plan shall be prepared by an architect, engineer, landscape architect or land surveyor whose state registration is current and valid.
iv. A design plan for new development, as defined in Section 4.02.01(C)(3), shall contain a development plan in accordance with the requirements of
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.