A. The costs of any catch basins or drop inlets shall be the responsibility of the developer.

These facilities shall be designed by the developer's appropriate state approved professional to Georgia Department of Transportation standards and shall be approved by the County. Catch basins shall be located outside of the intersection radii.

B. The spacing of catch basins shall be as follows:

1. Grades up to seven (7) percent: five hundred (500) feet.

2. Grades from seven (7) percent to ten (10) percent: four hundred (400) feet.

3. Grades over ten (10) percent: two hundred fifty (250) feet.

4. These spacing requirements can be altered if justified by sound engineering practice.

C. Cul-de-sacs on downhill street centerline grades shall have six (6) inch vertical curb and gutter along the circumference, beginning at the twenty-five (25) feet transition radius and ending at the second twenty-five (25) feet transition radius. A catch basin throat design detail shall be submitted for downhill street centerline grade cul-de-sacs.

D. A hooded grate may be used in an intersection radius on approval of the County.