A buffer shall be required whenever two adjoining properties are in dissimilar zone districts as shown in following Table 6.1. Table 6.1. Buffer Requirements Between Dissimilar Zone Districts Least Intensive Uses Most Intensive Uses RD Rural Dev. R-20 SingleFamily Res. R-6 MultiFamily Res PR Parks & Rec. OI Office & Inst. CR Comm. Res GC Gen. Com. LM Light Ind. GI Gen. Ind. RD Rural Development Buffer 6.1-1 Buffer 6.1-2 Buffer 6.1-2 Buffer 6.1-2 Buffer 6.1-2 Buffer 6.1-3 Buffer 6.1-4 Buffer 6.1-4 R-20 Single-Family Res. Buffer 6.1-2 Buffer 6.1-2 Buffer 6.1-2 Buffer 6.1-2 Buffer 6.1-3 Buffer 6.1-4 Buffer 6.1-4 R-6 Multi-Family Res. Buffer 6.1-1 Buffer 6.1-2 Buffer 6.1-1 Buffer 6.1-1 Buffer 6.1-1 Buffer 6.1-3 Buffer 6.1-3 Buffer 6.1-4 (Ord. No. 08-2012, § 3A., 8-27-2012) [Sec.] 6.1. Determination of Buffer Requirements Between Residential, Commercial and Industrial Zones. When two adjoining properties are dissimilar residential, commercial or industrial zone districts as indicated in Table 6.1, the property within the zone district allowing the most intensive uses is required to provide the buffer when acquiring a building permit, unless the buffer was pre-existing. When two adjoining vacant parcels are in dissimilar zone districts as indicated in Table 6.1, no buffer is required when the parcel zoned for the less intensive use acquires a building permit. 6.1-1 Buffer Requirement. The required buffer shall consist of plantings or a fence, wall (not otherwise part of a structure or accessory structure), or a berm, which meets the screening standards of Section 6.2 [when] plantings are chosen as the method of screening, the planting area shall have a minimum base width of twelve (12) feet. 6.1-2 Buffer Requirement. The required buffer shall consist of a fifty (50) foot setback from the adjoining property line containing not less than a twenty (20) foot base width consisting of plantings plus a fence, wall (not otherwise part of a structure or accessory structure), berm, or any combination thereof, which meets the screening standards of Section 6.2. 6.1-3 Buffer Requirement. The required buffer shall consist of a one hundred (100) foot setback from the adjoining property line containing not less than a twenty (20) foot base width consisting of plantings plus a fence, wall (not otherwise part of a structure or accessory structure), a berm, or any combination thereof, which meets the screening standards of Section 6.2. 6.1-4 Buffer Requirement. The required buffer shall consist of either an unvegetated five hundred (500) foot setback or two hundred (200) foot vegetated setback from the adjoining property line. A two hundred (200) foot minimum setback shall consist of seventy-five (75) foot [feet] of vegetated buffer area, measured along the entire portion of the property line abutting said use, and such buffer shall extend an additional one hundred (100) feet in each direction along the common property line. The seventy-five (75) foot vegetated buffer shall meet the planting requirements contained in Section 6.2. (Ord. No. 08-2012, § 3B.—D., 8-27-2012 [Sec.] 6.2. Screening Standards. Screening is a method of visually shielding or obscuring one use from another by fence, walls, a berm or densely planted vegetation. Plantings. Plantings shall consist of either trees or shrubs or any combination of both. Planted areas shall be located along the abutting property lines or in areas that will provide the best screening effectiveness. If trees or large shrubs are used solely as the screening device, they shall be any evergreen species from the list provided by the City Clerk which, under normal growing conditions, will attain a minimum height of eight (8) feet and a canopy spread of ten (10) feet within four (4) years. They shall be planted a minimum twenty (20) feet on center. If trees are used in combination with shrubs, they may be of any species from the list provided by the City Clerk. Small trees shall be planted thirty (30) feet on center, and large trees forty (40) feet on center as shown in the following illustration. Shrubs shall be any evergreen species from the list provided by the City Clerk planted four (4) feet on center as shown in the following illustration. Shrubs shall initially be of any size, which would normally attain a minimum height of six (6) feet within three (3) years after planting. _______________________________________________________________________________________ Walls. Walls shall be of masonry construction and a minimum height of eight (8) feet. The wall shall be placed on the edge of the buffer nearest the most intensive land use. Fences. Fences shall be a minimum of eight (8) feet in height and constructed of standard wood fencing materials and methods or chain link with woven inserts that will provide ninety percent (90%) visual blockage as shown in the examples provided by the Zoning Administrator. The fence shall be placed on the edge of the buffer nearest the most intense land use. Berms. Earthen berms shall have a minimum height of eight (8) feet. [Sec.] 6.3. Buffer Design. All buffers required by this article shall conform to the following specifications: