Gray · Zoning Ordinance
Appendix A - ZONING AND SUBDIVISION REGULATIONS / Article IX - SPECIAL PROVISIONS
92.5. Individual unit requirements.
About this text
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
(1) Seamless gutters and downspouts shall be provided on all buildings.
(2) Finished floor elevations of buildings shall be a minimum of eight inches higher than the adjoining finished grade.
(3) Roof shingles shall be a minimum 25-year, anti-fungal product, and are to be nailed (not stapled).
(4) Roofs shall be provided over the main entrance doors to all units that are accessed directly from the outside. All exterior doors are to be provided with a hard surface landing.
(5) Waterproofing shall be installed on exterior walls up to finished grade where finished floor elevations of apartment units or public spaces are below adjoining finished grades. A perimeter drain that discharges so as not to create a nuisance shall be provided for all below grade habitable spaces.
(6) Wood frame structures shall be fully sheathed with plywood, OSB, or similar material and provided with an appropriate drainage plane.
(7) The bottom of any non-masonry siding shall be a minimum height of six inches above the finished grade or mulch beds.
(8) All exhaust ducts shall discharge to the exterior of the building. Exterior wall caps for bath and kitchen exhaust ducts are to be of a quality that will minimize repair and replacement.
(9) Exterior wood, such as trim, fascia, rake boards and columns, shall be clad with vinyl, vinyl coated aluminum, or similar materials. Materials designed for cladding with a minimum thickness of 0.019 inch or thicker shall be used and provided with a stiffening crimp when trim and fascia boards are more than eight inches wide.
(10) Only vinyl, aluminum, or steel for railings, handrails, guard rails, posts and pickets shall be permitted. Wood shall not be used. Steel shall be primed and painted prior to placement in concrete.
(11) All apartment exterior doors, except sliding glass doors, shall be of insulated fiberglass or insulated metal. Solid core wood doors may be used where entrances are through interior conditioned corridors. Fiberglass or metal doors for outside storage or mechanical closets shall be required. All exterior door jambs shall be decay resistant.
(12) Hard surface flooring shall be installed at the interior of all entrance doors, except for doors entered through carpeted interior hallways. Hard surface area shall be at least three feet by three feet using flooring materials such as VCT, sheet vinyl, hardwood, or tile.
(13) All windows shall have blinds, shutters, or other similar products, and sliding glass doors shall have vertical blinds.
(14) A minimum of one and one-half bathrooms in all two bedroom units and a minimum of two full bathrooms in all three or more bedroom units shall be provided.
(15) Back porches and balconies are to be screened for privacy to a minimum height of 36 inches.
(16) All units shall be soundproofed between tenant spaces. The soundproofing used shall be of a non-combustible material.
(17) Appliances.
a. A 30-inch wide range shall be provided in all units except studio/efficiency and one bedroom elderly apartments, which may have a minimum 20-inch wide range.
b. A vented range hood or combination vented range hood-microwave over all cooking ranges shall be provided. All range hoods and over-the-range microwaves shall be ducted/vented to the outside. An automatic fire extinguisher shall be installed under the hood.
c. A 24-inch wide dishwasher shall be provided in all units, except for studio/ efficiency apartments, which may have 18-inch wide dishwashers.
d. All refrigerators shall be frost free. The refrigerators shall have separate doors for freezer and refrigerator compartments. Minimum sizes of refrigerators shall be 12 cubic feet for studio/efficiency apartments, 14 cubic feet for one and two bedroom apartments, and 16 cubic feet for three and four bedroom apartments.
e. Clothes washing machines and dryers or hookups for full-size side-by-side or full-size stack type washers and dryers shall be provided in all units. Laundry equipment shall be installed in a closet with doors in a location other than a living room or bedroom. Otherwise, provide onsite laundry facilities. (See "Plumbing" section for washing machine pan requirements.)
f. All appliances in an apartment unit shall match in color.
(18) Mechanical.
a. All refrigeration and condensation lines are to be concealed within walls.
b. Condensation lines shall discharge to a location that does not create a nuisance.
c. Condenser units shall not be permitted in front of windows.
d. Electric baseboard heating and forced air heating shall not be used as the primary heating method.
(19) Plumbing.
a. Clothes washing machines or hook-ups for clothes washing machines shall have a pan, with a drain to the exterior of the unit.
b. All water heaters shall be provided with a pan that drains to the exterior of the unit
c. All water pipe in exterior walls shall be insulated.
(20) Electrical.
a. All bedrooms, living rooms, family rooms, and dens shall be prewired for telephone, cable TV, and internet outlets. All wiring for the interior and exterior of the building shall be concealed within the walls.
b. Exterior lighting shall be provided to illuminate all parking areas and dumpster pads with a minimum of one foot candle of illumination. Illumination shall be provided so that the building numbers and apartment numbers are legible at night.
c. All exterior illumination shall be shielded to prevent light trespass.
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.