Appearance standards shall apply to all single-family detached dwellings including site-built housing, industrialized housing, and manufactured houses. Approval shall be granted upon finding that such development shall meet or exceed the Appearance standards as shown on Table 7.2: Appearance Standards for Single-Family Detached Dwellings. TABLE 7.2. APPEARANCE STANDARDS FOR SINGLE-FAMILY DETACHED DWELLINGS Type I RR Type II R-20 Type III R-40 Type IV MHP Min. Dwelling Width 24' 20' 16' 12' Min. Roof Pitch 4/12 3/12 3/12 2/12 Min. Heated Floor Area 1,600 sf 1,200 sf 1,000 sf 720 sf Roof Materials (1) (1) (1) External Siding Materials (2) (2) (2) Permanent Foundation Req'd (3) Req'd (3) Req'd Not req'd Utility Meter Mounted on Structure Mounted on Structure Mounted on Structure Mounted on Pole or structure Landing Area (4) (4) (4) Towing Devices (5) (5) (6) Notes: 1. The roof shall have a surface of wood shakes, asphalt composition, wood shingles, concrete, fiberglass tiles, metal tiles, slate, built up gravel materials or other materials approved by the building inspectors. 2. The exterior siding materials shall consist of wood, masonry, concrete, stucco, masonite, metal lap, vinyl lap, or other materials approved by the building inspector. 3. Permanent foundations shall meet the requirements of standard building code requirements for manufactured homes. For manufactured homes, a masonry curtain wall unpierced except for the required ventilation and access must be installed so that it encloses the area under the manufactured home to the ground level. 4. For manufactured homes, a landing area is required and its width and length must be greater than or equal to the width of the entrance doorway. 5. Manufactured homes are required to remove all towing devices. 6. Manufactured homes which cannot remove towing devices shall be screened by plantings and the structure shall be skirted.