Appendix A - ZONING / Article VI - SUPPLEMENTARY REGULATIONS

Sec. 6.250. Material standards.

About this text

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

The following apply to all facades of all buildings in residential or commercial zones.

a. Primary facade materials. Eighty (80) percent of each facade shall be constructed of primary materials.

1. Permitted primary facade materials include high quality, durable, finish materials. The following are acceptable primary facade materials: stone, brick, cement-based stucco, wood lap siding and shingles; fiber cement siding or shingles (such as HardiePlank, HardieShingle, or HardiePanel vertical siding or similar).

2. Other high quality synthetic materials may be approved by the director during the site plan process with an approved sample and examples of successful, high quality local installations.

3. Exposed concrete, synthetic stucco, unfinished wood, concrete masonry units (CMU), glass block, and vinyl are not permitted as a primary facade material.

4. Brick types larger than three (3) inches in height, such as economy bricks, are not permitted in any residential district.

b. Secondary facade materials. Secondary materials are limited to trim, details, and accent areas that combine to less than twenty (20) percent of the facade surface.

1. All primary materials may serve as secondary materials.

2. Additional secondary materials include fiber cement and wood; metal for beams, lintels, trim, and ornamentation; burnished, glazed, or honed concrete masonry units (CMU) or block for trim and details, but not surfaces; split-face, honed, or glazed concrete masonry units with a height less than four and one-half (4.5) inches for surfaces less than ten (10) percent of the facade surface; cast stone concrete elements; and vinyl for trim and details.

3. Synthetic stucco or exterior insulation and finishing systems (EIFS), such as dryvit, are permitted as a secondary material on upper floor facades only.

4. Burnished, glazed, or honed concrete masonry units (CMU) or block are permitted as secondary materials in commercial districts, for trim and details, but not surfaces. Splitface, honed, or glazed concrete masonry units with a height less than four and one-half (4.5) inches are permitted as secondary materials in commercial districts for surfaces less

than ten (10) percent of the facade surface. Scored concrete panels or block are not permitted.

c. Roof materials. Acceptable roof materials include two hundred (200) pound or better, dimensional asphalt composite shingles, wood shingles and shakes, metal tiles or standing seam, slate, and ceramic tile. "Engineered" wood or slate may be approved during the site plan review

process by the director with an approved sample and examples of successful, high quality local installations.

d. Color. Main building colors shall utilize any historic palettes from any major paint manufacturer. Other colors may be utilized for details and accents, not to exceed a total area larger than ten (10) percent of the facade surface area.

History

The history line the source prints at the end of the section.

(Ord. No. 2023-09-01, § 3, 10-10-2023)