a. Open space. Planned unit development shall designate at least thirty (30) percent of the site for contiguous open space as defined in Article I. The required open space shall not be fragmented. The calculation of contiguous open space shall not include strips of opens space less than fifty (50) feet wide. The locations of the open space shall be reviewed at the time of rezoning and be dependent upon the internal layout of the project and the adjacent uses. Where properties do not require rezoning, open space shall be reviewed as part of the subdivision preliminary plat. Internally located open space may be needed to compliment the overall project open space requirements, while perimeter open space may be needed to provide a transition or separation from an adjacent lower density residential or agricultural use. b. Building and design standards. The building and design standards for planned unit development are increased to ensure that planned unit developments align with the overall character of and vision for the city. Planned unit development shall comply with the following building and design standards: (1) Building elevations. Building elevations shall be provided for each housing type within the planned unit development. Elevations shall not repeat for every three (3) consecutive structures. (2) Exterior building materials. Exterior building materials shall consist of one of the following: i. Brick or brick veneer; ii. Stucco; iii. Fiber cement siding; iv. Other materials may be approved upon review and approval by the director or their designee. (3) Accent building materials. A minimum of two exterior accent materials are required for each structure. c. Connectivity. Neighborhoods are to be interconnected and connect to adjacent neighborhood. Flexibility for connections shall be provided to preserve on-site environmental resources and preservation areas. Internal connections shall occur through streets and multimodal connections. d. Mixture of dwelling (lot) types. Each planned unit development shall contain at least two (2) different dwelling types from Table 8.020.d. For planned unit developments that exceed ten (10) acres no less than twenty (20) percent and no more than sixty (60) percent should be provided of one housing type or lot size out of the dwelling types to be provided: Table 8.020.d. Dwelling Types Dwelling Type Lot Size Minimum Lot Width Lot Arrangement/Placement Perimeter Lot/Estate House 15,001 sq. ft. or greater 100' External (perimeter) and Internal permitted Single-Family Detached Dwelling Type 1 10,001—15,000 sq. ft. 65'/75' where located along the perimeter External (perimeter) and Internal permitted Single-Family Detached Dwelling Type 2 7,501—10,000 sq. ft. 55' Internal to site (i.e. not on periphery of boundary of development) Single-Family Detached Dwelling Type 3 5,000—7,500 sq. ft. 45' Internal to site; no more than 20% of the total dwellings Single-Family Attached Dwelling Per R-C2 District Standards for Single Family Attached Dwelling Internal to site; no more than 20% of the total dwellings Multi-Family Dwelling Per R-HD District Standards for Multi-Family Dwelling Internal to site; no more than 20% of the total dwellings e. Based on the development size, the following requirements apply to the PUD development: Development Size (Acres) Number of Dwelling Types Required Required Non-Residential (Square Footage) Required Open Space (Percentage) 5—10 2 0 20% 10—25 3 5,000 30% ≥ 25 4 10,000 30% f. Buffering. A fifteen (15) foot perimeter buffer, shall be provided for planned unit developments. The perimeter buffer may be counted towards no more than fifty (50) percent of the required open space percentage. Perimeter buffers begin at the common property line, immediately abutting the adjacent property. Perimeter buffers shall not encroach upon the required setbacks nor shall buffers or required landscaping within buffers be within the boundary of a sight triangle along any right-of-way. The dimensions and other standards relating to sight triangles are within section 6.050. These buffers may also allow pedestrian paths and access points for utilities and vehicles within the buffers. All buffers shall be platted as separate tracts to be owned and maintained by the Homeowners' Association, Property Owners' Association, or similar entity. Perimeter buffers for planned unit developments shall comply with the following standards: 1. Fifteen (15) foot width; 2. Three (3) trees per every one hundred (100) linear feet; 3. One (1) understory tree per one hundred (100) linear feet; 4. Fifty (50) shrubs per every one hundred (100) linear feet; 5. Six (6) foot fence. Planned Unit Development Buffer Illustration g. Buffers at road intersections. To maintain a sight triangle as intersection not controlled by stop signs, perimeter buffers shall be designed to allow for view of oncoming traffic. See section 6.050 for intersection setback standards. h. Alternative buffer plan. (1) At the discretion of the planning commission, alternate buffering plans, plant material, planting methods, or landscape design may be used where unreasonable or impractical situations would result from application of buffering requirements, or where necessary to protect existing vegetation, or where a more creative plan is proposed which substantially complies with the intent of these requirements. Buffering requirements may be reduced if existing trees or other types of existing vegetation are preserved. Alternative plans, materials, or methods may be justified from natural conditions such as streams, natural rock formations, topography, and other physical conditions related to the site. Lot configuration and the presence and location of utility easements may justify an alternative buffering plan.