Hall County · Zoning Ordinance
Appendix A - UNIFIED DEVELOPMENT CODE
6.1.6. District Standards
About this text
- As published by Municode, current through 2026-05-28
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
A. Planned Residential Development
(PRD)
1. Intent. A planned residential development is designed to allow for a more flexible placement, arrangement, and orientation of residential structures, the accompanying flexibility in the subdivision of land, and the grouping of open space and accessory facilities such as garages and parking. It may also provide for a mixture of housing types such as singlefamily, two-family, multi-family, townhomes, cottage court, and livework according to a carefully designed plan. The proposed
residential development should make maximum use of natural features and, through proper site planning measures, should conform to the existing character and development pattern of the surrounding area.
Every effort should be made to preserve and protect any existing residential uses from adverse impacts which might result from a higher density development.
Table 6.1.1. PRD Dimensional Standards Lots (Single-family detached) Lot area:
(note 1) 8,000 sq. ft. min.
Lot width: 50 ft. min.
Density: 2 dwellings/acre max.
Yards (Single-family detached) Front yard: 25 ft. min.
Side yard: 5 ft. min.
Rear yard: 20 ft. min Lots (Two-family residential) Lot area:
(note 1) 30,000 sq. ft. min.
Lot width: 60 ft. min.
Yards (Two-family residential) Front yard: 30 ft. min.
Side yard: 10 ft. min.
Rear yard: 20 ft. min.
Lots (Single-family attached and multifamily) Lot area:
(note 2) 35,000 sq. ft. min.
Lot area:
(note 3) 40,000 sq. ft. min.
Building Height Maximum:
75 ft. max. for multifamily 50 ft. max. for all others Table Notes:
1. For lots with access to sanitary sewer. The minimum lot area for lots without access to sanitary sewer is determined by the Hall County Environmental Health Department.
2. For multi-family and single-family attached with 3 units.
3. For multi-family and single-family attached with more than 3 units.
2. Application Requirements. All the general and special requirements in Secs. 6.1.2 and 6.1.3 for planned developments must be provided. The following special items must be addressed:
a. The site plan must indicate the proposed size, location, number of units and number of bedrooms of all residential structures.
b. All streets and common open spaces not proposed for dedication to the county must have the proposed maintenance and
ownership agreements explained in detail.
c. The architectural style and proposed siting of all multifamily structures or attached single-family structures must
be indicated. Architectural standards for all planned residential developments are as indicated in Sec. 6.1.6.A.8.
d. The development controls for the development must be detailed, including lot coverage, setbacks, building heights, and lot sizes.
e. Planned developments of at least 5 acres in size may include commercial uses within the development, limited to neighborhood retail intended to serve the needs of the residents of the development unless otherwise specifically approved by the Board of Commissioners. Retail uses must be specified as part of the
proposal and are limited to no more than 10,000 square feet of floor area for the entire development site.
3. Dimensional Standards. See Table
6.1.1 for district standards and Sec.
2.1 (Measurements and Exceptions) for additional requirements.
4. Buffers. A buffer at least 50 feet in width must be established along the
perimeter of all property boundaries adjacent to residential and nonresidential districts to ensure
that the planned residential development is appropriately screened. Buffers must meet the standards of Sec. 8.2.4.
5. Landscaping. In addition to the tree protection requirements of Sec.
8.3, the following standards apply in planned residential developments:
a. At least two trees per lot must be provided. Trees may be located in the front, side, or rear yard.
i. These trees may not be counted towards the developments tree density unit requirement.
ii. Trees located within any utility easement, drainage easement, or septic drain field may not count
towards the per lot tree requirement.
b. The developer is responsible for planting or preserving the individual lot trees prior to issuance of a certificate of occupancy.
6. Access. In addition to the requirements of Article 9 (Subdivisions) the following standards apply in all
planned residential developments:
a. Any PRD with 150 or more lots must include at least two vehicular entrances with access to a city, state, or county maintained public right-ofway. The second entrance must be completed prior to the platting of 150 lots or more.
b. Any PRD with 400 or more lots must include at least three vehicular entrances with access to a city, state, or county maintained public right-ofway.
i. The county may waive the requirement for immediate construction of a third entrance based on the
development schedule and phasing plan.
c. In addition to the requirements of Sec. 8.4 and any applicable provisions of Article
9, sidewalks must be installed on both sides of any proposed street.
7. Open Space. Open space is required in all PRD districts as follows:
a. Open space must comprise at least 30% of the gross lot area.
b. All other standards of Sec. 4.8.7 apply.
8. Architectural Standards. The following architectural standards apply to all PRD districts:
a. Building materials. All facades of residential structures and any permitted nonresidential structures must be finished with brick, stone, stucco, wood siding, wood shake, or cementitious siding.
Vinyl siding is not permitted.
i. The front facade must incorporate a variety in building material, texture or color.
b. Garages. Garages for singlefamily detached and two-family structures on lots less than one acre in size must meet one
of the following standards.
i. Flush. Garage doors are oriented towards the street. Garage doors may be positioned flush with the front wall plane of the residence, extending no more than 55 percent of the width of the residence.
ii. Semi-flush. Garage doors are oriented towards the street. Garage doors may be positioned within 10 feet of flush with the front wall plane of the residence in either direction, extending no more than 55 percent of the width of
the residence.
iii. Recessed. Garage doors are oriented towards the street. Garage doors must be positioned at least 10 feet behind the front wall plane of the residence, extending no more than 55 percent of the width of the residence.
iv. Side-loaded. Garage doors are oriented perpendicular to the front wall plane of the residence. Any wall of the garage must be located at least 3 feet behind the front wall plane of the residence.
v. Carriage court. Garage doors are oriented perpendicular to the front wall plane. All garage walls are located entirely in front of the front wall plane of the residence.
vi. Detached. The garage is placed entirely to the rear of the residence.
c. Townhouses. For townhouses garage placement must meet the following standards.
Townhouses fronting an arterial or collector street must be rear loaded. Townhouses fronting a minor street may be rearloaded or front-loaded.
i. Rear-loaded. The garage must be placed entirely to the rear of the townhouse and may be attached or detached. Garage doors must face a rear right-ofway or easement. For detached garages, the
garage must be either located 4 feet from the rear right-of-way or easement, or be a minimum of 20 feet from the rear rightof-way or easement.
ii. Front-loaded. A minimum of 20 feet is required between the garage and the back of sidewalk.
9. Footing Inspections. At the time of the footing inspection, the contractor must provide the county building official with a certificate from a licensed surveyor certifying building setbacks for all corners of the structure being inspected.
10. Cluster Mailbox Unit (CBU).
Pursuant to Unites States Postal Service Policy, all new subdivisions and new phases of existing subdivisions are required to provide CBU's for regular mail service delivery. A
CBU is a structure or shelter housing multiple mailbox units to serve each residential dwelling of the
development for the express purpose of regular mail delivery provided by the USPS. The following standards are for construction and maintenance of CBU's for all planned residential developments.
a. The developer is responsible for confirming the logistics of regular mail delivery to CBU's with the USPS. As such, all CBU's are subject to final approval by the USPS.
b. Maintenance. The county will not assume any responsibility for the maintenance and repairs of CBU's and associated parking areas. The CBU's and associated parking areas are
to be maintained by the homeowners' association, managing entity, or collectively by the property owners.
c. Location. CBU's must be located on their own lot or in an area dedicated for open space or on a public access easement obtained by the developer. The entrance to the proposed vehicular parking area must be located at least 200 feet from the main entrance and at least 60 feet from any street intersection.
d. Parking. The minimum parking ratios established on Table
6.1.2. must be met for all CBU's:
Table 6.1.2. PRD Dimensional Standards Number of Mailboxes Required shortterm parking 50 or less 3 51—78 4 79—104 5 105 or more 5 plus 1 for every additional 25 mailboxes
e. Property Management. A person owning or having possession or control of any property within a PRD must
meet the following property management standards in addition to any conditions of approval placed upon the
development as detailed in Sec.
6.1.3:
i. Any damaged, dead, diseased or decaying plant materials must be removed and replaced if visible from the public right-of-way.
ii. Premises occupied by a residential dwelling must be maintained free from grass, similar vegetation or uncultivated vegetation in excess of 12 inches in height.
iii. Fences facing a street or adjacent public right-ofway must be regularly maintained, repaired, and
replaced if considered necessary by the building official.
B. Planned Office Development (POD)
1. A Planned Office Development is designed to contain orderly, welldesigned office and institutional uses upon a site that results in minimum
impact upon the surrounding area.
The site plans and building designs should produce a development that can be constructed to achieve maximum utilization of space while maintaining a low-intensity office character protected from more intensive commercial and industrial development and protecting any nearby residential uses.
2. Planned Office Developments may also include a limited number of residential and commercial uses.
3. All the general and special requirements in Secs. 6.1.2 and 6.1.3 for planned developments must be
provided. The following special items should also be addressed:
a. The site plan must indicate the proposed size, location, and number of stories in each office building.
b. The development controls for the district must be detailed, including lot coverage, setbacks, building heights, and lot sizes.
If standards are not specifically proposed, then the applicable standards in the
Office Institutional (O-I) districts in Sec. 5.1, including screening and buffer requirements, apply.
c. If residential uses are proposed in conjunction with the planned office development, then the applicable requirements of the planned residential developAPPENDIX A—UNIFIED DEVELOPMENT CODE § 6.1 ment district or planned commercial development district must be provided.
C. Planned Commercial Development
(PCD)
1. A Planned Commercial Development is designed to provide for the maximum attainable commercial
usage of property while employing the best aspects of site planning and development controls to insure:
a. Protection of surrounding residential uses;
b. Safe access by motorists;
c. Minimum traffic congestion;
and
d. A development which is consistent with long-range plans of the county.
2. A limited number of carefully planned residential uses may also be included in a Planned Commercial Development.
3. All the general and special requirements in Secs. 6.1.2 and 6.1.3 for planned developments must be
provided. The following specific items must also be addressed:
a. A site plan indicating the proposed site preparation and grading, streets and parking areas, loading zones, storm drainage, water, gas and sewage systems, and all buffer areas.
b. The development controls for the district must be detailed, including lot coverage, setbacks, building heights, and lot sizes.
If standards are not specifically proposed, then the applicable standards in the
Suburban Shopping (S-S) district in Sec. 5.2, including screening and buffer requirements, apply.
D. Planned Industrial Development
(PID)
1. A Planned Industrial Development is designed to consist of land which has been designated for a planned, organized and controlled industrial use or for multiple but compatible industrial uses in a planned industrial park. The standards must be designed to encourage the formation and continuance of a compatible environment for the planned industrial uses and the surrounding land uses.
2. Carefully planned office and commercial uses may be incorporated as part of a Planned Industrial
Development.
3. All of the general and special requirements for planned developments in Secs. 6.1.2 and 6.1.3 must be
provided. The following specific items must also be addressed:
a. A site plan indicating the proposed site preparation and grading, streets and parking areas, loading zones, outdoor storage areas, rail facilities, storm drainage, water, gas and sewage systems and all buffer areas.
b. The development controls for the district must be detailed, including lot coverage, setbacks, building heights, and lot sizes.
If standards are not specifically proposed, then the applicable standards in the
Light Industrial (I-1) district in Sec. 5.5, including screening and buffer requirements, apply.
c. If office or commercial uses are proposed in conjunction with the Planned Industrial Development, then the applicable requirements in the POD or
PCD district must be provided.
Meetings that refer to this section
- Hall County Planning Commission, June 16, 2025 (Minutes)Refers to this section in the minutes: “§6.1.6”
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.