Hall County · Zoning Ordinance
Appendix A - UNIFIED DEVELOPMENT CODE / 8.2 - Fencing and Buffers
8.2.4. Buffer Types and Standards
About this text
- As published by Municode, current through 2026-05-28
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
A. General
1. Buffers must be undisturbed and may contain no structures except for walls, fences, or structures otherwise allowed in the buffer by this UDC.
2. Buffers may be made up of existing vegetation or planted vegetation or a combination of the two.
3. Buffers must be located wholly on the subject property.
4. The owner of the property on which the buffer is located is responsible for the maintenance, repair, and replacement of the required buffer.
5. The vegetation must be located or planted far enough from the property lines to prevent encroachment into adjacent properties.
6. The required buffer must be installed prior to occupancy or commencement of use. Where compliance with the preceding is not possible because
of the season of the year, the Building Official may grant a temporary occupancy permit until the season
changes.
B. Buffer Material
1. The buffer strip must be planted as specified in Table 8.2.1 and must consist of evergreen trees or shrubs at least 5 feet in height at the time of planting, spaced to provide a continuous screen when mature.
a. Where buffer widths greater than 10 feet are required, the remaining buffer adjacent to the residential district use may be left in a natural forested state, if such condition exists, or planted with a mix of deciduous and evergreen trees.
b. Where existing vegetative material in good condition meeting the minimum height remains in the buffer area after clearing and construction, it may be utilized and credited toward meeting the screening requirement. The county must approve the materials and planting plan for the buffer prior to the buffer being established.
2. Spacing of plants should be the minimum required for mature plants, and staggered rows of plantings may be used if necessary to attain the required initial screening. Screening plants must be nursery-grown and of such size, species, and condition as to ensure the maximum initial screening commensurate with
a high rate of survival and a high growth rate. Other trees planted to re-establish a forested area must be a minimum caliper of at least three inches at the time of planting.
3. Earthen berms may be incorporated in the buffer design upon approval by the Director after a determination that the berms will not cause drainage or erosion problems to the
subject site or adjacent properties.
4. A structural buffer such as a solid fence or wall may be substituted, Buffer Design Standards, Figure 8-1 upon approval from the Director, for part or all of the vegetated buffer as follows:
a. A brick or stone wall at least 6 feet in height may be erected adjacent to the property line in lieu of the buffer requirements.
b. A solid wooden fence at least 6 feet in height may be erected adjacent to the property line.
The fence must have a natural finish and the finished side of the fence must face the adjacent property. If stained or varnished, the resulting finish must be natural in appearance.
5. For nonresidential uses with outdoor storage, the construction of both a vegetative and structural buffer must be provided upon determination by the Director that the buffer requirement will otherwise be insufficient to achieve the desired level of screening.
C. Buffer Height The screening vegetation must attain a minimum height of 10 feet within five years of establishment of the buffer. Where the required interim growth has not been attained, the property owner is responsible for replacing the vegetation with new
vegetation that will meet the buffer requirement within the remaining portion of the original five-year period.
D. Buffer Width The buffer width must be as indicated in Table 8.2.1 unless a structural buffer has been approved in accordance with Sec.
8.2.4.B.4.
E. Maintenance of Buffer All buffers required by this section must be maintained in a healthy condition and pruned to provide a solid screen with
maximum opacity from the ground to a height of at least ten feet. Should vegetation die or be removed such that the buffer no longer functions as required,
that vegetation must be replaced by the property owner. Fences or walls serving as a buffer must remain in a good state of repair to provide a solid screen.
F. Vision Clearance at Intersections In all districts no plantings, fences, walls, signs or other obstruction to vision
between the heights of 3 feet and 15 feet may be permitted within 25 feet of the
intersection of the right-of-way lines of two streets, railroads or driveways, and a public road.
G. Modification of Buffer Requirements
1. The Board of Commissioners may modify or waive the buffer requirements on rezonings and uses subject to their approval upon determination that the buffer is not necessary or creates a hardship.
2. The Planning Commission may modify or waive the buffer requirements on uses subject to their approval upon determination that
the buffer is not necessary or creates a hardship.
3. The Director may modify or waive the buffer requirements on plan approvals not subject to Planning Commission or Board of Commissioners review, based on a specific finding that existing topography,
vegetation, building orientation or other physical characteristics of the area will provide screening and buffering that meets the intent of this section.
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.