Sec. 93-11.2-12. Commercial design ground floor requirements.

About this text

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

In addition to the requirements of section 93-11.2-10, the following shall apply to buildings with enfronting ground floor commercial uses;

and all enfronting buildings along South Central Avenue, North Central Avenue, Virginia Avenue, International Boulevard, or Atlanta Avenue:

(1) Enfronting ground floor facades shall provide a display window area consisting of:

a. A non-glass base or knee wall beginning at grade and extending not more than 24 inches above the

required sidewalk.

b. A glass display window beginning at the top of the bulkhead or knee wall, to a height not less than ten feet and not more than 12 feet above the adjacent required sidewalk. Such glass shall provide views into display windows that have a minimum depth of 21 /2 feet into and are accessible from the building interior.

c. Primary pedestrian entrances to all commercial uses adjacent to the front yard shall be recessed a maximum of five feet from the exterior facade, remain unlocked during normal business hours, and have a surface area that is a minimum of 70 percent

glass.

d. A glass transom located above the glass display window and entry door shall have a minimum height of 24 inches and a maximum height of 36 inches.

e. A minimum of 75 percent of the length of the enfronted portion of the build-to line shall be provided in glass, including glass doors and display windows.

f. No linear distance of more than ten feet without intervening glass display windows or glass doors.

g. A non-glass sign band located above the glass transom having a minimum height of 36 inches.

(2) Ground floor drop ceilings shall be recessed a minimum of 18 inches from the display window opening.

(3) The ground floor finished floor to ceiling slab shall be a minimum of 18 feet.

Finished ceiling height shall be a minimum of 14 feet.

(Ord. No. 2005-11, § 3(8-5-120R), 11-15-2005;

Ord. No. 2015-15, § 14, 8-4-2015)