All multifamily housing developments, which are not SFA and/or condominium projects and do not include units for individual sale, all units in which are or will remain in one ownership by an individual, partnership or corporation, shall have a masonry or concrete firewall and/or floors (as described in the city building code, sections 602—607) with a four-hour fire rating. These walls shall be constructed between every ten units. Combustible members shall not extend through these walls and/or floors.