--- title: Haralson Zoning Ordinance, 5.10. Appearance Standards collection: local-codes id: local-code:haralson/zoning/5.10 cite_as: Haralson, Ga., Zoning Ordinance § 5.10 canonical_url: https://georgiacommons.org/code/local/haralson/zoning/5.10 md_url: https://georgiacommons.org/code/local/haralson/zoning/5.10.md text_url: https://georgiacommons.org/code/local/haralson/zoning/5.10/text source_url: https://library.municode.com/ga/haralson date: 2026-11-11 status: active jurisdiction: city:haralson jurisdiction_name: Haralson place_fips: "1336528" corpus_version: local-codes-haralson-da13393e121d publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/haralson/zoning/~appendix-a/~article-5.md previous: https://georgiacommons.org/code/local/haralson/zoning/appendix-a-article-5-5.9.md next: https://georgiacommons.org/code/local/haralson/zoning/5.11.md index: https://georgiacommons.org/code/local/haralson.md branch: zoning edition: As published by Municode, retrieved 2026-11-11 edition_date_kind: retrieved source_publisher: Municode version_id: local-code:haralson/zoning/5.10@2026-11-11-15de4f7e93 --- # Haralson Zoning Ordinance, 5.10. Appearance Standards > As published by Municode, retrieved 2026-11-11 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Appendix A - ZONING / Article 5 - ZONING DISTRICT STANDARDS AND PERMITED USES In addition to standards listed elsewhere in this article, the following appearance standards shall apply. Certificate of occupancy shall be granted upon the finding that such development shall meet or exceed the appearance standards as follows: A. Residential. 1. All single-family dwellings (RD, R-40, RC, and R-1 districts) excluding industrialized housing, manufactured homes and modular buildings: a. Roof. The roof will have a minimum vertical rise of four feet (4') for each twelve feet (12') of horizontal run and shall have a surface of wood shakes, asphalt composition, wood shingles, concrete, fiberglass or metal tiles, slate, built up gravel materials or other materials approved by the building inspector. b. Siding. The exterior siding materials shall consist of wood, masonry, concrete, stucco, masonite, metal or vinyl lap or other materials of like appearance. c. Foundation. A permanent foundation is required and shall meet the requirements of standard building codes. 2. Industrialized Homes, Manufactured Homes or Modular Buildings, as defined herein may be permitted in any residential zoning district other than the RC district, provided such buildings or structures meet the following standards: a. Standards. (1) The structure has a minimum width in excess of sixteen feet (16'). (2) The pitch of the structure's roof has a minimum vertical rise of four feet (4') for each twelve feet (12') of horizontal run, and the roof is finished with a type of shingle that is commonly used in conventional construction. (3) The exterior siding consists of wood, hardboard, vinyl, brick, masonry, or aluminum (vinyl-covered or painted, but in no case exceeding the reflectivity of glass white paint) comparable in composition, appearance, and durability to the exterior siding commonly used in conventional construction. (4) A curtain wall, unpierced except for required ventilation and access and constructed of masonry, is installed so that it encloses the area located under the home to the ground level. Such a wall must have a minimum thickness of four inches (4"). (5) The tongue, axles, transporting lights, and towing apparatus are removed after placement on the lot and before occupancy. (6) Landings of the requisite composition and size as per Section 1113 of the Standard Building Code of the Southern Building Code Congress International are installed, with said provisions being expressly incorporated by reference herein as part of this requirement. b. Conditions. All pre-owned manufactured homes located in the jurisdiction shall bear a label certifying it was constructed in compliance with the National Manufactured Housing Construction and Safety Standards Act of 1974, 42 U.S.C. Section 5401, et seq. (the HUD Code) and shall be installed in accordance with O.C.G.A. § 8-2-160, et seq. c. Permitting, Inspection, Certificate of Occupancy and Fees. A permit shall be required to locate a pre-owned manufactured home in the jurisdiction. All permits shall be issued within five (5) business days of receipt of all items listed in subsections (a)(1)—(4) of this section. To obtain a permit, Applicants shall provide to the building inspector: (1) An affidavit signed by the applicant that the pre-owned manufactured home meets health and safety standards required by this Act; (2) Photographs of the interior and exterior of the pre-owned manufactured home providing evidence that home meets the minimum health and safety standards of Section 4 of this ordinance; (3) A One thousand dollars ($1,000.00) refundable guarantee of condition bond or $1,000.00 refundable cash deposit; and (4) The permit and inspection fee required by this section. (5) Upon receipt of a permit, Applicants may relocate the manufactured home on a residential site for the purposes of inspection. Applicant shall arrange for an inspection to be held once the installation of the manufactured home is complete. (6) Certificate of Occupancy. A certificate of occupancy shall be issued to the Applicant at such time that the building inspector certifies that the requirements of this ordinance have been met. (7) Fee. A permit and inspection fee shall be charged to the applicant to cover the cost to the City to process the permit application and inspect the pre-owned manufactured home. Such fee shall cover the initial inspection and one follow-up inspection. The applicant shall pay a fee for each additional followup inspection that may be necessary, subject to the discretion of the building inspector. (8) Alternative Inspection. At the request of the Applicant, the building inspector may, at his or her discretion, inspect a pre-owned manufactured home prior to its being relocated if the home is then located at another site within the city. The structure will still be subject to all other necessary inspections. (9) The fees to be charged under this section shall be as established by the city or the building department, and shall approximate the cost to the city of providing the inspections services. d. Minimum Health and Safety Standards. All pre-owned manufactured homes shall comply with the following before being issued a certificate of occupancy by the building inspector: (1) HUD Code. Every pre-owned manufactured home located in the jurisdiction shall be in compliance with the Federal Manufactured Housing Construction and Safety Standards Act, 42 U.S.C. 5401— 5445 (the HUD Code) and shall not have been altered in such a way that the home no longer meets the HUD Code. (2) Interior Condition. Every floor, interior wall, and ceiling of a preowned manufactured home shall be in sound condition. Doors and windows shall be operable, watertight and in good working condition. The floor system shall be in sound condition and free of warping, holes, water damage, or deterioration. (3) Exterior Condition. The exterior of all pre-owned manufactured homes shall be free of loose or rotting boards or timbers and any other conditions that might admit rain or moisture to the interior portions of the walls or to occupied spaces. The exterior siding shall be free of rot and rust. Roofs shall be structurally sound and have no obvious defects that might admit rain or cause moisture to collect on the interior portion of the home. (4) Sanitary Facilities. Every plumbing fixture, water, and waste pipe of a pre-owned manufactured home shall be in a sanitary working condition when properly connected, and shall be free from leaks and obstructions. Each home shall contain a kitchen sink. Each bathroom shall contain a lavatory and water closet. At least one bathroom shall contain a tub and/or shower facilities. Each of these fixtures shall be checked upon being connected to ensure they are in good working condition. (5) Heating Systems. Heating shall be safe and in working condition. Un-vented heaters shall be prohibited. (6) Electrical Systems. Electrical systems (switches, receptacles, fixtures, etc.) shall be properly installed and wired and shall be in working condition. Distribution panels shall be in compliance with the approved listing, complete with required breakers, with all unused openings covered with solid covers approved and listed for that purpose. The home shall be subject to an electrical continuity test to assure that all metallic parts are properly bonded. (7) Hot Water Supply. Each home shall contain a water heater in safe and working condition. (8) Egress Windows. Each bedroom of a manufactured home shall have at least one operable window of sufficient size to allow egress if necessary. (9) Ventilation. The kitchen in the home shall have at least one operating window or other ventilation device. (10) Smoke Detectors. Each pre-owned manufactured home shall contain one operable battery-powered smoke detector in each bedroom and in the kitchen, which must be installed in accordance with the manufacturer's recommendations. e. Enforcement. (1) Permanent connection to utilities shall not be approved until the building inspector has issued a certificate of occupancy. (2) Owners of pre-owned manufactured homes that are not in compliance upon a third inspection shall have their permit revoked and shall be required to remove the home from the jurisdiction at their own expense. (3) The guarantee of condition bond or cash deposit will be forfeited after 90 days from the date of inspection, unless all conditions and standards are met prior to the end of the 90 days or an extension has been issued in writing by the building inspector. f. Penalties Failure to remove a pre-owned manufactured home from the jurisdiction upon failure to receive a certificate of occupancy shall be punishable by a fine as authorized by the Charter of the City of Haralson. Each day any violation under this ordinance continues shall be considered a separate offense. B. Commercial. All commercial buildings (GC and GI) in the Commercial Overlay District are required to comply with design standards specified in Article 8. Commercial buildings outside the Commercial Overlay District are encouraged to comply with the design standards specified in Article 8.