(a) Site plan applications. The following information shall be submitted with all site plan applications for new commercial, industrial, and multifamily residential development: (1) The location of all freestanding, building-mounted and canopy outdoor lighting fixtures and all adjacent street lights, where applicable; (2) Building elevations for all structures on the site plan; (3) A written description of each illuminating device, fixture, lamp, support and shield. The description may include, but is not limited to, manufacturer's catalog cuts and drawings including elevations where required, lamp types and wattage output; (4) A photometric grid overlay indicating the overall light intensity in foot candles at the property lines of the site; and (5) Any additional information that may be necessary to adequately review the site plan application for compliance with the provisions of this article. (b) Building permit applications. The following information shall be submitted with all building permit applications for new commercial, industrial, and multifamily residential development: (1) Verification that all outdoor light fixtures with a bulb producing more than 680 lumens have a full cutoff style fixture directed downward; (2) Verification that no outdoor lighting fixture, with the exception of motion activated lighting, will create an intensity of light greater than one-half foot candle at a property line that abuts residentially zoned property; and (3) Any additional information that may be necessary to adequately review the building permit application for compliance with the provisions of this article.