In addition to the requirements of this Development Code for the submission of printed copies, as-built data drawings and all final plats approved
for recordation shall be submitted to the Community Development Director in a digital format as follows:
(a) Digital drawing files shall be submitted in AutoCAD DWG or DXF format and shall include:
(1) Final plat as approved.
(2) Model space drawing of the engineering plans, reflecting any changes approved by the Community
Development Department.
(b) The DXF or DWG file shall have data divided into the following distinct and separate layers:
(1) Parcel Lines (PL).
(2) Right-of-Way (ROW).
(3) Boundary (BL).
(4) Water Lines (WL), when available.
(5) Sewer Lines (SL), when available.
(6) Electrical Lines (EL), when available.
(7) GPS Monuments, when required or available.
(c) In engineering plans, line and arc data must be unbroken where appropriate, such as no breaks in intersecting lot lines at corner pins and no breaks in utility lines.
(d) The projection shall be in Georgia State Plane West Coordinate System North American Datum 1983.
(e) Control shall be indicated.
(f) Such additional information or requirements as may be established by the Community Development Director or
designee necessary to convert the DXF or DWG file to ArcGIS format.