--- title: Harris County Zoning Ordinance, 831.05. Building standards for AO zones collection: local-codes id: local-code:harris-county/zoning/831.05 cite_as: Harris County, Ga., Zoning Ordinance ยง 831.05 canonical_url: https://georgiacommons.org/code/local/harris-county/zoning/831.05 md_url: https://georgiacommons.org/code/local/harris-county/zoning/831.05.md text_url: https://georgiacommons.org/code/local/harris-county/zoning/831.05/text source_url: https://library.municode.com/ga/harris_county/codes/code_of_ordinances date: 2023-12-05 status: active jurisdiction: county:harris jurisdiction_name: Harris County county_fips: "13145" corpus_version: local-codes-harris-county-7fc9415fb593 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/harris-county/zoning/~appendix-a/~article-8/~division-6.md previous: https://georgiacommons.org/code/local/harris-county/zoning/831.04.md next: https://georgiacommons.org/code/local/harris-county/zoning/831.06.md index: https://georgiacommons.org/code/local/harris-county.md branch: zoning edition: As published by Municode, current through 2023-12-05 edition_date_kind: current_through source_publisher: Municode version_id: local-code:harris-county/zoning/831.05@2023-12-05-695a31685a --- # Harris County Zoning Ordinance, 831.05. Building standards for AO zones > As published by Municode, current through 2023-12-05 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Appendix A - UNIFIED DEVELOPMENT CODE / Article 8 - ENVIRONMENTAL RESOURCES PROTECTION / Division 6 - FLOOD DAMAGE PREVENTION / 831 - Standards. Areas of special flood hazard established in Section 830.01 may include designated "AO" shallow flooding areas. These areas have base flood depths of one to three feet above ground, with no clearly defined channel. The following provisions apply: (a) All new construction and substantial improvements of residential and nonresidential structures shall have the lowest floor, including basement, elevated to the flood depth number specified on the flood insurance rate map (FIRM), above the highest adjacent grade. If no flood depth number is specified, the lowest floor, including basement, shall be elevated at least three feet above the highest adjacent grade. Openings sufficient to facilitate the unimpeded movements of floodwaters shall be provided in accordance with standards of subsection 831.01(d), "elevated buildings". The building inspection director shall certify the lowest floor elevation level and the record shall become a permanent part of the permit file. (b) New construction or the substantial improvement of a non-residential structure may be floodproofed in lieu of elevation. The structure, together with attendant utility and sanitary facilities, must be designed to be watertight to the specified FIRM flood level plus one foot above highest adjacent grade, with walls substantially impermeable to the passage of water, and structural components having the capability of resisting hydrostatic and hydrodynamic loads and the effect of buoyancy. A registered professional engineer or architect shall certify that the design and methods of construction are in accordance with accepted standards of practice for meeting the provisions above, and shall provide such certification to the officials set forth above and as required by permit application provisions per Section 834. (c) Drainage paths shall be provided to guide floodwater around and away from any proposed structure.