a. Vehicular access from properties to streets shall comply with the following dimensional requirements, measured at the right-of-way line:

Maximum Driveway Width* Minimum Driveway Width Two-Way One-Way Single-Family Residence 25 feet 8 feet 8 feet Multi-Family Residential 36 feet 26 feet 12 feet Commercial & Industrial 36 feet 30 feet 16 feet

* Includes divided entrances with center islands.

b. Along major streets other than State or U.S. highways, no more than two (2) points of vehicular access from a property to each abutting public street shall be permitted for each four hundred (400) feet of lot frontage, or fraction thereof; provided however, that lots with less than one hundred (100) feet of frontage shall have no more than one point of access to any one public street.

c. Along State or U.S. highways, no more than one point of vehicular access from a property shall be permitted for each three hundred (300) feet of lot frontage, or fraction thereof.

d. Driveway connections. Driveway connections shall be provided between the edge of pavement or back of curb to the right-of-way line. No property may be afforded access from a public street except as follows:

(1) Curb and gutter streets shall be provided with a driveway apron constructed of 3000 psi concrete at least six (6) inches thick. Sidewalks, where provided, shall be warped to the driveway apron.

(2) Swale ditch section streets shall be provided with a driveway apron constructed of 3000 psi concrete at least six (6) inches thick, or asphaltic concrete of the same thickness and type as the paving course(s) for the street.

(3) All driveway aprons shall have a radius connecting the driveway to the curb line or pavement edge as follows:

Land Use Minimum Driveway Radius Single-Family Residential 6 feet Commercial or Multi-Family 15 feet Industrial 25 feet Example—Residential Driveway Apron