(a) Purpose: The intent and purpose of the R-4 multifamily residential zoning classification is to provide an affordable residential housing opportunity at a density which optimize land area, wherein there are no restrictions upon rental of such properties. (b) Permitted uses: (1) Condominiums. (2) Apartments. (3) Public recreation areas. (4) Existing cemeteries. (5) Unrestricted rentals. (c) Conditional uses: (1) Public and quasi-public buildings. (2) Churches with a minimum of one acre. (3) Private recreational areas. (d) Accessory uses: (1) Swimming pools. (2) Club houses (nonprofit). (3) Tennis courts. (4) Private greenhouses. (e) Development standards: (1) Minimum lot size: 40,000 square feet. (2) Minimum lot width: 100 feet. (3) Minimum road frontage: 100 feet. (4) Front setbacks along a state highway: 50 feet. (5) Rear setback: 15 feet. (6) Side setback: 10 feet. (7) Side setback along a street: 10 feet. (8) Maximum top floor elevation: 40 feet. (9) Coverage: Condominium (percentage) Apartment (percentage) Building 30 35 Open space 25 25 Green space 45 40 (10) Height ratio for occupied floors: For every one foot height increase over 30 feet the front and side setbacks increase by six inches. For example: Top Floor Height Front Setback Side Setback 30 ft. 10 ft. 10 ft. 31 ft. 10 ft. 6 in. 10 ft. 6 in. 32 ft. 11 ft. 11 ft. 50 ft. 20 ft. 20 ft. (11) Buffer requirements. A planted buffer will be required as set forth in division 4. (12) Site plan. A site plan for the proposed development shall be prepared by a registered civil engineer or landscape architect and submitted to the planning and design review board for approval before any land disturbing activities shall be undertaken. The site plan at the least should provide a metes and bounds description of the proposed development, provide topographic survey information on the site at two-foot contours; show the proposed size and location of all buildings and structures, the size and location of all buildings and structures, the size and location of all existing easements, rights-of-way and utilities, the proposed location of all proposed utilities, access to the site and circulation within it, the location size and types of trees to be retained, any other landscaping or site improvements which shall be made. Six copies of this site plan shall be furnished to the planning and design review board. (13) The development of the site, alternative parking methods may be used including elevated or belowground structures which are integrated into the development. (f) Yard requirements. (1) Front yard: No parking areas, structures, fence or patios shall be allowed in the first ten feet of a front yard, measured from the street or highway right-of-way. Walks shall be allowed but shall not occupy more than ten percent of the first ten feet of front yard, except that when it is not feasible to construct a sidewalk parallel to the street within the street or highway right-of-way. Where such conditions exist, a sidewalk of no more than five feet in width will be allowed upon approval of the planning and design review board. The remaining area shall be planted in plant material. (2) Rear yard: No parking, structures or pavement shall be in the first ten feet of rear yard measured from the rear property line. Open walks and patios shall be allowed but shall not occupy more than ten percent of the ten-foot area. The remaining area shall be planted in plant material. (Ord. No. 90-3, ยง 5, 6-19-90; Ord. No. 96-04-01, 5-21-96; Ord. No. 98-04-01, 6-25-98; Ord. No. 06-06-02, 7-11-06)