--- title: Helen Zoning Ordinance, Sec. 34-673. Sand and oil/grease traps collection: local-codes id: local-code:helen/zoning/34-673 cite_as: Helen, Ga., Zoning Ordinance ยง 34-673 canonical_url: https://georgiacommons.org/code/local/helen/zoning/34-673 md_url: https://georgiacommons.org/code/local/helen/zoning/34-673.md text_url: https://georgiacommons.org/code/local/helen/zoning/34-673/text source_url: https://library.municode.com/ga/helen/codes/code_of_ordinances date: 2026-11-11 status: active jurisdiction: city:helen jurisdiction_name: Helen place_fips: "1337788" corpus_version: local-codes-helen-1f7e0711f162 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/helen/zoning/~part-ii/~chapter-34/~article-iv/~division-2.md previous: https://georgiacommons.org/code/local/helen/zoning/34-672.md next: https://georgiacommons.org/code/local/helen/zoning/34-674.md index: https://georgiacommons.org/code/local/helen.md branch: zoning edition: As published by Municode, retrieved 2026-11-11 edition_date_kind: retrieved source_publisher: Municode version_id: local-code:helen/zoning/34-673@2026-11-11-beade2e553 --- # Helen Zoning Ordinance, Sec. 34-673. Sand and oil/grease traps > As published by Municode, retrieved 2026-11-11 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE / Chapter 34 - LAND DEVELOPMENT CODE / Article IV - LAND DEVELOPMENT ORDINANCE / Division 2 - ADMINISTRATION AND ENFORCEMENT (a) Requirement for. (1) All users involved in the preparation of food for commercial purposes shall provide oil/grease traps. Grease traps shall be designed as appropriate for the size of the facility as specified in subsection (b), below. Additionally, any user who generates a wastewater which contains greater than the quantity of oil and grease than 100 mg/L, and provided that the excess oil and grease is floatable and can be effectively removed in an oil/grease trap, then said user will be required to install an oil/grease trap. (2) All users whose wastewater stream is associated with unusually large quantities of grit, sand or gravel shall be required to install a sand trap. All car/truck wash systems shall be required to install a sand trap; design specifications and calculations must be submitted and approved by the city before installation. (3) No originator may cause or permit any F.O.G. to bypass or avoid the oil/grease trap. (4) The requirements of this ordinance section shall not apply to private living quarters or dwelling units. (b) Design criteria. (1) For restaurants and other eating establishments. a. Required except as provided in c. below. All oil/grease traps used in conjunction with restaurants or other eating establishments shall be a minimum of 1500 gallons and shall have a total volume size to be such to allow one change of contents per 24 hour period. All oil/grease traps must be designed in accordance with Department of Human Resources Public Health, Chapter 290-5-26 Section 12, Grease Traps. b. Required except as provided in c. below. All existing in ground oil/grease traps, for existing eating establishments, must have a filter system installed on the discharge side of the trap. c. Under the counter oil/grease traps are determined to constitute a high risk of failure to prevent F.O.G. from contaminating the public sewer system and are not recommended, and specifically discouraged. However, due to various circumstances existing within the city, all existing and anticipated originators may not be able to provide an in ground oil/grease trap, and therefore, under the counter oil/grease traps will be permitted as hereinafter provided in this subdivision. All such under the counter oil/grease traps must be designed so that they prevent water flow if the trap is filled to capacity and, when filled to capacity the water flow will back up unless the trap is cleaned out. d. All oil/grease traps shall be designed to fully and efficiently function at the maximum daily flow. e. Design details, specifications and calculations must be submitted and approved by the city before installation. (c) Maintenance. (1) All grease, oil and sand traps shall be maintained by the user at their expense, in continuously efficient operation at all times. (2) In the maintaining of grease traps, the owner shall be responsible for the proper removal and disposal by appropriate means of the captured material, and shall maintain records of the dates, and means of disposal, which are subject to review by the city. All manifests or other records of removal shall be provided to the city on a quarterly basis. The frequency of removal shall be such as to ensure that no overflows of oil, grease or sand into the wastewater system ever result. The frequency for maintaining these traps shall, at the minimum, be as follows based on the classifications listed: Class I - Food establishments with an under-the-counter trap: Monthly. Class II - Food establishments with an in ground oil/grease trap of at least 1,500 gallons and serving less than 100 customers in a 24-hour day, during the highest annual serving 24-hour period: Two times per year. Class III - Food establishments with an in ground oil/grease trap of at least 1,500 gallons and serving more than 100 customers but less than 250 customers in a 24-hour day, during the highest annual serving 24-hour period: Four times per year. Class IV - Food establishments with an in ground oil/grease trap of at least 1,500 gallons and serving more than 250 customers in a 24-hour day, during the highest annual serving 24-hour period: Monthly. (d) Under the counter oil/grease traps. (1) Under the counter oil/grease traps shall not be permitted in any food establishment using a dishwashing machine. (2) Under the counter oil/grease traps shall be allowed only upon application for an annual permit for an under the under counter oil/grease trap. All such permit applications shall provide such information as required by the application developed by the city manager, and shall contain at least the following: (a) a full and complete description of the under the under counter oil/grease trap; (b) the capacity of the oil/grease trap; (c) the location, and means of access, of the oil/grease trap; (d) the manufacturer's and/or installers recommendations for maintenance of the oil/grease trap; and (e) the expected useful life of the oil/grease trap. (e) Proper disposal of collected materials. A current licensed waste disposal firm must perform any removal and hauling of the collected materials from the sand/oil/grease traps. Under no circumstances shall the collected materials ever be returned to the city's wastewater collection system. It is the responsibility of the originator to provide the city, within ten days of waste disposal firm's manifests showing compliance with the maintenance provisions of oil/grease traps. ## History (Ord. No. 06-08-01, 9-19-06)