Sec. 34-943. Building standards for streams without established base flood elevations and/or floodway (A zones).

About this text

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

Located within the areas of special flood hazard established in section 34-922, where streams exist but no base flood data have been provided (A zones), or where base flood data have been provided but a floodway has not been delineated, the following provisions apply:

(1) When base flood elevation data or floodway data have not been provided in accordance with section 34-922, then the city planning design and review board shall obtain, review, and reasonably utilize any scientific or historic base flood elevation and floodway data available from a federal, state, or other source, in order to administer the provisions of division 4, only if data are not available from these sources, then the following provisions (2) and (3) shall apply:

(2) No encroachments, including structures or fill material, shall be located within an area equal to the width of the stream or 20 feet, whichever is greater, measured from the top of the stream bank, unless certification by a registered professional engineer is provided demonstrating that such encroachment shall not result in an increase greater than that allowed by the Federal Emergency Management Agency (FEMA) Flood Insurance Study, latest edition, in flood levels during the occurrence of the base flood discharge.

(3) In special flood hazard areas without base flood elevation data, new construction and substantial improvements of existing structures shall have the lowest floor of the lowest enclosed area (including basement) elevated no less than three feet above the highest adjacent grade at the building site. Openings sufficient to facilitate the unimpeded movements of flood waters shall be provided in accordance with standards of section 34-941(4), "Elevated buildings."

a. All heating and air conditioning equipment and components (including ductwork), all electrical, ventilation, plumbing and other service facilities shall be elevated no less than three feet above the highest adjacent grade at the building site.

The city planning design and review board shall certify the lowest floor elevation level and the record shall become a permanent part of the permit file.

History

The history line the source prints at the end of the section.

(Ord. No. 02-11-01, 12-17-02; Ord. No. 04-03-01, 4-20-04; Ord. No. 17-10-01, 11-7-17)