Jasper · Zoning Ordinance
Part II - CODE OF ORDINANCES / Chapter 94 - ZONING / Article VII - LOT AND SITE DEVELOPMENT FEATURES / Division 7.7 - OTHER REGULATIONS
Sec. 94-160. Outdoor lighting.
About this text
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
(a) Purpose and intent. This section is intended to reduce the problems created by improperly designed and installed outdoor lighting. They are intended to eliminate problems of glare and minimize light trespass, with regulations that avoid unnecessary direct light from shining onto abutting properties or streets.
(b) Applicability. Outdoor lighting installed in the city shall be in conformance with the requirements established by this section.
(c) Exemptions. The following shall be exempt from the provisions of this section:
(1) All temporary emergency lighting needed by police or fire departments or other emergency services;
(2) All hazard warning luminaires required by federal regulatory agencies;
(3) All vehicular luminaires;
(4) Safety lighting, as defined in this section;
(5) All outdoor light fixtures producing light directly by the combustion of natural gas or other fossil fuels;
(6) Signs as permitted in chapter 95.
(7) Aesthetic lighting limited to interior roadway lighting with a maximum height of two feet within a development, not intended to take the place of required street lighting, or lighting to be utilized within open space used to feature decorative plantings, sidewalks, walkways, or ornamental objects, such as fountains or similar features. Aesthetic lighting, although exempt from an isometric foot=candle plan, shall be identified on all design plans as to type of light and location to ensure appropriate use of aesthetic lighting in accordance with this section.
(d) Outdoor lighting regulations.
(1) Cutoff fixtures. All luminaires not exempted from this section hereafter installed for outdoor lighting shall be full cutoff luminaires or another luminaire which does not emit any direct light above a horizontal plane through the lowest direct-light-emitting part of the luminaire
(2) Type of lighting. Outdoor lighting shall be CFL or LED.
(3) Glare. See chapter 26, section 26-57(11).
(4) No lighting plan shall be approved which will result in direct light that exceeds the requirements or is otherwise inconsistent with this section.
(5) Intensity specifications. Illuminance levels for outdoor lighting fixtures shall comply with the standards in Table 94-160a. and b measured at three feet above ground or finished grade.
Table 94-160a - Illuminance levels at property lines At Property Lines Including Rights-Of-Way Minimum Footcandles Maximum Footcandles At property line abutting a residential use 0 0.5 At property line abutting an office or institutional use 0 1.0 At property line abutting a commercial or industrial use 0 1.5 Table 94-160b - Illuminance levels in parking lots Off-Street Parking Lots Minimum Footcandles Average Footcandles Maximum Footcandles Residential uses 0.5 2.0—3.0 4 Institutional and agricultural uses
1.0 3.0—4.0 6 Commercial uses 2.0 6.0—7.0 12 Industrial uses 1.0 4.0—5.0 8
(e) Plans required.
(1) Applicants for any permit for any single-family detached or attached use proposing outdoor lighting fixtures shall submit evidence that the proposed work will comply with the outdoor lighting regulations of this section.
a. The submission shall include a description, count, and location of all proposed outdoor illuminating devices, fixtures, lamps, supports, reflectors. The description may include, but is not limited to, catalog cuts and illustrations by manufacturers.
b. Wood light poles are prohibited in all districts.
(2) Applicants for any permit for any non-single-family use proposing outdoor lighting fixtures shall submit evidence that the proposed work will comply with the outdoor lighting regulations of this section in accordance with the following:
a. Plans indicating the location on the premises of each outdoor illuminating device, both proposed and any already existing on the site.
b. Description of all proposed illuminating devices, fixtures, lamps, supports, reflectors. The description shall include, but is not limited to, catalog cuts, and illustrations by manufacturers.
c. Photometric data, such as that furnished by manufacturers or similar, showing the angle of cut-off of light emissions.
d. Photometric plans shall include the maximum and average light layout.
History
(Ord. No. 2021-01, § 1(Attch.), 2-1-2021; Ord. No. 2023-07, § 1(a)(Exhs. 1—3), 6-5-2023; Ord. No. 2024-10, § 5, 5-6-2024)
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.