Johns Creek · Zoning Ordinance
Appendix A - ZONING / Article XI - COMMUNITY/NEIGHBORHOOD/MOBILE HOME DISTRICTS
12A.3.10.4. General Architectural Standards.
About this text
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
A. Applicability.
1. The following applies to all buildings, except as specifically stated otherwise.
2. Detached houses, cottage courts, duplexes, townhouses, walk-up flats, and stacked flats must comply with either this Section or Section 12A.3.10.5., at the discretion of the applicant.
B. Building Material.
1. Exterior finish materials on walls visible from a street, Creekside Pond, linear park, or a civic space must be limited to brick, manufactured stone, architectural block, natural stone, wood siding, cement-based siding, cement-based panels, and/or hard coat stucco, except that glass and metal curtain wall systems are allowed to be used on all building stories above the second floor.
2. Hard coat stucco, when used as an exterior wall finish material, is subject to the following additional standards:
a. Hard coat stucco may not exceed 30% of the total wall area (excluding foundations) visible from a street, Creekside Pond, linear park, or a civic space. For the purpose of calculating conformance with this requirement, windows and doors are not included in the total wall area.
b. The maximum wall length (excluding foundations) visible from a street, Creekside Pond, linear park, or a civic space that is finished with hard coat stucco is 60 feet.
Authorized wall lengths finished in hard coat stucco must be separated by a minimum wall length of 60 feet that contains no hard coat stucco.
3. Exterior finish materials must be combined in such a way to provide form and visual interest in proportion to the building height and intended use, with the visually heavier below the lighter as shown in the table below. This does not apply to architectural details such as cornices, window sills, and beltlines.
Visual Weight Visually Lighter Visually Heavier Hard Coat Stucco Wood/Cement-based Siding or Panel Brick Architectural Block Natural/Manufactured Stone
4. The number of different exterior finish materials, textures, colors, or combinations thereof, used on a single building, should be proportional to the mass and height, and limited to avoid visual clutter, excluding materials used on windows, doors, front porches, balconies, foundations, awnings, or architectural details.
5. Foundations must be constructed as a distinct building element that is finished in a different material or color than the exterior wall. Exposed above-ground foundations must be coated or faced in cement, brick, manufactured stone, or natural stone to contrast with façade materials.
C. Building Façade. The following applies to all street-facing facades.
1. Where used, shutters must match one-half the width and shape of the window opening to which they are adjacent to appear functional.
2. Facades must provide visual divisions between the ground story and second story through architectural means such as courses, awnings, or a change in materials.
3. Facades must delineate all stories above the ground story with windows, belt courses, balconies, cornice lines or similar architectural detailing.
4. Windows must be recessed a minimum of 3 inches and a maximum of 8 inches from the adjacent façade or window trim/casing, whichever is greater.
D. Building Massing.
1. The footprint of buildings containing any residential uses shall not exceed 75,000 square feet. The building footprint size limitation shall not include any parking structures provided to serve the principal use(s).
2. Facades over 40 feet in length must incorporate block breaks, wall projections, or recesses a minimum of 12 inches in depth. The combined length of said recesses and projections must constitute at least 20% of the total facade length.
3. Variation in the roofline of buildings and offsets in pitched roofs and gables are required.
Parapets in individual building facades exceeding 100 continuous linear feet must be varied in height and projection and must use decorative elements such as crown moldings, dentals, brick soldier courses, or similar details.
4. The roofs of buildings may include cisterns and green roofs if part of an approved stormwater management plan for the site and if designed in accordance with the latest version of the Georgia Stormwater Management Design Manual. Above-ground cisterns require architectural and/or landscape screening that compliments the architecture of the building and is of like or similar materials used in the building's construction. The cisterns and other vertical runoff reduction measures and their screening shall require approval by the Community Development Director.
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.