--- title: Kennesaw Zoning Ordinance, 3.07.11. Buffer Zones collection: local-codes id: local-code:kennesaw/zoning/3.07.11 cite_as: Kennesaw, Ga., Zoning Ordinance § 3.07.11 canonical_url: https://georgiacommons.org/code/local/kennesaw/zoning/3.07.11 md_url: https://georgiacommons.org/code/local/kennesaw/zoning/3.07.11.md text_url: https://georgiacommons.org/code/local/kennesaw/zoning/3.07.11/text source_url: https://library.municode.com/ga/kennesaw/codes/code_of_ordinances date: 2026-11-11 status: active jurisdiction: city:kennesaw jurisdiction_name: Kennesaw place_fips: "1343192" corpus_version: local-codes-kennesaw-1e0c921092e2 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/kennesaw/zoning/~appendix-a/~chapter-3.md previous: https://georgiacommons.org/code/local/kennesaw/zoning/3.07.10.md next: https://georgiacommons.org/code/local/kennesaw/zoning/3.07.12.md index: https://georgiacommons.org/code/local/kennesaw.md branch: zoning edition: As published by Municode, retrieved 2026-11-11 edition_date_kind: retrieved source_publisher: Municode version_id: local-code:kennesaw/zoning/3.07.11@2026-11-11-fb5ea08de0 --- # Kennesaw Zoning Ordinance, 3.07.11. Buffer Zones > As published by Municode, retrieved 2026-11-11 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Appendix A - UNIFIED DEVELOPMENT CODE / Chapter 3 - PROTECTION OF NATURAL FEATURES AND RESOURCES 1. All properties zoned commercial, office institutional, and industrial zoned shall establish a buffer along any property line that abuts a residential district. This standard also applies to screening from residential property separated by right-of-way and transmission easements. 2. All properties zoned mixed use and multi-family shall establish a buffer zone along any property line abutting a single family residential district. This standard also applies to screening from single family residential property that is separated by right-of-way and transmission easements. 3. Buffer zones shall incorporate tree specimens that will provide total screening of activity from property lines. 4. Combination of berms, hedges and tree installation to accomplish the intent of these standards shall be approved by the Director. Installation height for trees in these zones shall be at least five feet and be of an evergreen variety. 5. Landscaping buffer zones will meet the following minimum widths for each district: 3.07 LI and HI - 50 feet 3.08 PVC, PSC, HGB, GC - 40 feet 3.09 CRC, NRC - 35 feet 3.10 RM-8, RM-12, MHP - 25 feet 3.11 01, NS - 20 feet 3.12 PUD-RRA-4, FST, HPV, UVC - 10 feet 3.13 SLO - 10 feet 3.14 HIS See historic district regulations 6. For subdivisions, all buffers shall be delineated on the final plat and identified as tree conservation easements. Final plats shall also identify any individual lots with other tree conservation and/or planting requirements. These lots shall be identified on the plat with a symbol and a corresponding note indicating the homebuilder's responsibility for such tree conservation and/or planting requirements. Protection of Trees during Construction 1. Developers shall make all reasonable efforts to protect retained trees during the construction process, including, but not limited to, the following measures: a. Placing protective barriers around trees, and marking such areas with "tree save area" signs; b. Not grading, excavating, or locating utilities within the trees' critical root zone (CRZ); c. Maintaining the CRZ as a pervious surface; and, d. Maintaining the topsoil in the CRZ and preventing siltation. 2. Tree protection devices shall be installed prior to the issuance of a land use permit for any clearing and/or grading. Tree protection shall consist of chain link fencing, orange laminated plastic fencing supported by posts, rail fencing, or other equivalent restraining material. Tree protection devices shall remain in functioning condition throughout all phases of development and shall be subject to inspection by the Director. (See Figure). Fl",£E LOCATION (LIMIT5 OF C.RITICAL ROOT ZONE) TREE PROTECTION ## History (Ord. No. 2015-14, Att., 12-21-15; Ord. No. 2021-07, § 6(Exh. C), 6-21-21)