6.02.15. Vertical Alignment/Intersection Approaches
About this text
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
A. For the intersections oflocal and residential collector streets, a leveling of the street at a grade not exceeding 2 percent shall be provided for a minimum tangent length of 25 feet.
Exemptions are allowed for topographic considerations as determined by the design professional and the Public Works Director.
B. As a street approaches an intersection with a street classified in the Major Thoroughfare Plan, the approach shall be in accordance with the CDOT standards.
C. Tangent length is measured from edge of pavement of the intersecting street to the point of curvature in the approaching street.
D. This grade for the landing may be 1 percent.
History
(Ord. No. 2018-21, § l(Exh. B), 10-15-18)