Kennesaw · Zoning Ordinance
Appendix A - UNIFIED DEVELOPMENT CODE
6.02.33. Curbing
About this text
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
A. Concrete shall be Class "A" (as defined by GDOT) and have a minimum strength of 3,000 psi at 28 days.
B. Typical minimum section (residential subdivision only) shall be 6" x 24" x 12" for vertical curb (see Standard Detail 106) unless otherwise specified by COOT or GDOT. A six (6") inches by thirty (30") inches by twelve (12") inches section may be required on non-residential local and collector roads.
C. ½-inch expansion joints or pre-molded bituminous expansion joint material shall be provided at all structures and radius points and at intervals not to exceed 250 feet in the remainder of the curb and gutter as shown on Standard Detail 106.
D. When the development ties into existing curbing, the curb and gutter shall match the existing width.
E. Where driveway access must be made through existing curbing, the curbing must be saw cut 2' wider than the driveway throat on either side and the driveway throat curbing extended to the point of saw cut and completed with a finished joint.
History
(Ord. No. 2018-21, § l(Exh. B), 10-15-18)