A. Sub-grade preparation should be completed according to the City of Kennesaw Developmental Standards.
B. Grading and compaction of the area should be completed so as to eliminate yielding or pumping of soil.
C. Sub-grade must be uniform and have a minimum of 95 percent standard proctor density.
D. Unsuitable soil shall be removed from the area. If unsuitable soil cannot be removed from the area due to environmental conditions, a soil reinforcement mat and additional gravel stone base shall be used to meet the required compaction density.
History
(Ord. No. 2006-06, § 1(18-48), 2-21-06)