Skip to content
Georgia Commons
Menu

Kennesaw · Zoning Ordinance

Appendix A - UNIFIED DEVELOPMENT CODE / Chapter 4 - SITE DESIGN STANDARDS / Article 1 - 2 3

Article 1. 2 3

About this text

  • As published by Municode, retrieved 2026-11-11
  • The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.

1. Minimum setbacks and building separations shall be subject to fire and building code restrictions.

2. Transect Zone notwithstanding, along State Routes the mininum required frontage buildout shall be 50%.

3. Additional stories allowed by approved variance in T5 zone. HPC review required, as applicable.

3.[4.] In T4-Limited and T4-Open different Building Function requirements apply.

(Ord. No. 2016-03, Att., 3-7-16) TABLE 11A: Code Graphics - T3

BUILDING

CONFIGURATION

1. Building height shall be measured in number of Stories, excluding Attics and above ground portions of basements.

2. Stories may not exceed 14 feet in height from finished floor to finished ceiling.

l. BUILDING FUNCTION (See Table 9 & Table 10)

SETBACKS -

PRINCIPAL BLDG.

1. The Facades and Elevations of Principal Buildings shall be distanced from the Lot lines as shown.

2. Facades shall be built along the Principal Frontage to the minimum specified width in the table.

Residential restricted use Lodging prohibited use Office restricted use Retail prohibited use

k. BUILDING FORM (See Table 6) Principal Building 2 stories max.

Outbuilding 1 story max.

f. LOT OCCUPATION (See Table 11 section e) Lot Width 70 ft. min.

Lot Coverage 50% max.

i. BUILDING PLACEMENT (See Table 6)

SETBACKS -

OUTBUILDING

1. The Elevations of the Outbuilding shall be distanced from the Lot lines as shown.

Edgeyard permitted Sideyard not permitted Rearyard not permitted Courtyard not permitted

g. SETBACKS - PRINCIPAL BUILDING (See Table 11 section f) (g.1) Front Setback

Principal 24 ft. min.

(g.2) Front Setback Secondary 12 ft. min.

(g.3) Side Setback 12 ft. min.

(g.4) Rear Setback 12 ft. min.* Frontage Buildout 30% min. at setback

h. SETBACKS - OUTBUILDING (See

Table 11 section g) (h.1) Front Setback Principal 20 ft. min. + bldg.

setback (h.2) Front Setback Secondary 3 ft. min. or 6 ft.

min. at corner (h.3) Side Setback 3 ft. min.

*or 15 feet from center line of alley -- (See Table 1) /!'JI'------

- - - - ·r - - - , -tt2) - - - - - - ·- 1

.. , ! I II

I I I ton.I.GI : h"'>{ t. ca,_, (h.1) (h.1) I (h.2) Ii ca-.

- ·- ·- ·- ·L·- - _ _ t_--~----------J J

j. PRIVATE FRONTAGES (See Table 8) PARKING PLACEMENT

1. Uncovered parking spaces may be provided within the second and third Layer as shown in the diagram (see Table 12 section d).

2. Covered parking shall be provided within the third Layer as shown in the diagram (see Table 12 section d). Side- or rear-entry garages may be allowed in the first or second Layer by Warrant.

3. Trash containers shall be stored within the third Layer.

Common Lawn permitted Porch & Fence permitted Terrace or Lightwell not permitted Forecourt not permitted Stoop not permitted Shopfront & Awning not permitted Gallery not permitted Arcade not permitted Refer to Summary Table 11 $N$ stands for any Stories above those shown, up to the maximum. Refer to metrics for exact minimums and maximums.

(Ord. No. 2016-03, Att., 3-7-16)

APPENDIX A—UNIFIED DEVELOPMENT CODE Art. 5 t:l ''-----====------ r- - ·- ·- ·- ·r ·- ·~ FfOl"4lgl: ·- ·- - ·- ·- ·- ·- ·""! · I I ! 1-----,--------, i ii : i Ji l I I ~i I j l: !

i : i I i : j I ! i. ·- ·- ·- ·- · L ·- ·- ·- ·L..-- .- ·- ·- ·- ·- ·- ·- ·- ·- ·..1 ,.

,._ 2nd ,._ 20ft TABLE 11B: Code Graphics - T4

BUILDING

CONFIGURATION

1. Building height shall be measured in number of Stories, excluding Attics and above ground portions of basements.

2. Stories may not exceed 14 feet in height from finished floor to finished ceiling, except for a first floor Commercial function which must be a minimum of 11 ft with a maximum of 25 feet.

3. Height shall be measured to the eave or roof deck as specified on Table 5.

l. BUILDING FUNCTION (See Table 9 & Table 10)

SETBACKS -

PRINCIPAL BLDG.

1. The Facades and Elevations of Principal Buildings shall be distanced from the Lot lines as shown.

2. Facades shall be built along the Principal Frontage to the minimum specified width in the table.

Residential limited use* Lodging limited use* Office limited use* Retail limited use*

k. BUILDING FORM (See Table 6) Principal Building 3 stories max.

Outbuilding 2 stories max.

f. LOT OCCUPATION (See Table 11 section e) Lot Width 18 ft. min.

Lot Coverage 65% max.

Building Footprint 20,000 sf max.

* In T4-Limited and T4-Open different Building Function requirements apply.

--~ l r~--:--~~'1 c-c, -- (See Table 1) ,. r - - <u.2,- - - I I (g 1) (g ► ~ [=~ : (g.1) -.j•·-----,g--,--l ·: [= I (g.3) L __ ...._ ____ T,.--------~

i. BUILDING PLACEMENT (See Table 6)

SETBACKS -

OUTBUILDING

1. The Elevations of the Outbuilding shall be distanced from the Lot lines as shown.

Edgeyard permitted Sideyard permitted Rearyard permitted Courtyard not permitted

g. SETBACKS - PRINCIPAL BUILDING (See Table 11 section f) (g.1) Front Setback

Principal 15 ft. min., 30 ft.

max.

(g.2) Front Setback Secondary 15 ft. min., 30 ft.

max.

(g.3) Side Setback 3 ft. min.

(g.4) Rear Setback 3 ft. min.** Frontage Buildout 40% min. at setback

h. SETBACKS - OUTBUILDING (See

Table 11 section g) (h.1) Front Setback Principal 20 ft. min. + bldg.

setback (h.2) Front Setback Secondary 0 ft. min. or 3 ft.

min. at corner (h.3) Side Setback 3 ft. min.

j. PRIVATE FRONTAGES (See Table 8) PARKING PLACEMENT

1. Uncovered parking spaces may be provided within the third Layer as shown in the diagram (see Table 12 section d).

2. Covered parking shall be provided within the third Layer as shown in the diagram (see Table 12 section d).

3. Trash containers shall be stored within the third Layer.

Common Lawn not permitted Porch & Fence permitted Terrace or Lightwell not permitted Forecourt not permitted Stoop not permitted Shopfront & Awning permitted Gallery permitted Arcade not permitted Refer to Summary Table 11 &N& stands for any Stories above those shown, up to the maximum. Refer to metrics for exact minimums and maximums.

(Ord. No. 2016-03, Att., 3-7-16) ** or 15 feet from center line of alley.

APPENDIX A—UNIFIED DEVELOPMENT CODE Art. 5 I \I

r - -,- - - -1~f..""!!'O!. - - - - - - -,T I

f:

I:

I L ·- ,.,. 2nd ,.,.

20ft

' I I I I

I I I I I I I

I I I I I I : IJ Jnl Lo,- TABLE 11C: Code Graphics - T5

BUILDING

CONFIGURATION

1. Building height shall be measured in number of Stories, excluding Attics and above ground portions of basements.

2. Stories may not exceed 14 feet in height from finished floor to finished ceiling, except for a first floor Commercial function which must be a minimum of 11 ft with a maximum of 25 feet.

3. Height shall be measured to the eave or roof deck as specified on Table 8.

l. BUILDING FUNCTION (See Table 9 & Table 10)

SETBACKS -

PRINCIPAL BLDG.

1. The Facades and Elevations of Principal Buildings shall be distanced from the Lot lines as shown.

2. Facades shall be built along the Principal Frontage to the minimum specified width in the table.

Residential open use Lodging open use Office open use Retail open use

k. BUILDING FORM (See Table 6) Principal Building 3 stories max.* Outbuilding 2 stories max.

f. LOT OCCUPATION (See Table 11 section e) Lot Width 18 ft. min.

Lot Coverage 85% max.

Building Footprint 20,000 sf max.

*HPC review required, as applicable.

i. BUILDING PLACEMENT (See Table 6)

SETBACKS -

OUTBUILDING

1. The Elevations of the Outbuilding shall be distanced from the Lot lines as shown.

Edgeyard not permitted Sideyard permitted Rearyard permitted Courtyard not permitted

g. SETBACKS - PRINCIPAL BUILDING (See Table 11 section f) (g.1) Front Setback

Principal 0 ft. min., 15 ft.

max.

(g.2) Front Setback Secondary 0 ft. min., 15 ft.

max.

(g.3) Side Setback 0 ft. min.

(g.4) Rear Setback 3 ft. min.** Frontage Buildout 70% min. at setback

h. SETBACKS - OUTBUILDING (See

Table 11g) (h.1) Front Setback Principal 5 ft. min.

(h.2) Front Setback Secondary 5 ft. min.

(h.3) Side Setback 3 ft. max.

j. PRIVATE FRONTAGES (See Table 8) PARKING PLACEMENT

1. Uncovered parking spaces may be provided within the third Layer as shown in the diagram (see Table 12 section d).

2. Covered parking shall be provided within the third Layer as shown in the diagram (see Table 12 section d).

3. Trash containers shall be stored within the third Layer.

Common Lawn not permitted Porch & Fence permitted Terrace or Lightwell not permitted Forecourt not permitted Stoop not permitted Shopfront & Awning permitted Gallery permitted Arcade not permitted Refer to Summary Table 11 'N' stands for any Stories above those shown, up to the maximum. Refer to metrics for exact minimums and maximums.

(Ord. No. 2016-03, Att., 3-7-16) ** or 15 feet from center line of alley.

APPENDIX A—UNIFIED DEVELOPMENT CODE Art. 5 / u u u u_~ r - - - - - - - - - - - - - T: -(h] ) - - -r

• I I : I I l Oomlrlot

• I (h.1) I I t.ondlllDn

-· I :. I 40• ,..._ I" -------- --------- -- ------ ------·· ·- --------►-- -- -- -----

• I I ·-.- I I (h.3)• I ~ l Mid·8kd

• I (h.t) I I CcnMior!

I : I

• L - J t u ~,,_u u ~ r,---, -------------, . I I I

I I I

. I I I

.f: I I I I I .~: I I

I I !, I I I

. L J ISi 2nd 3nl ,_ '""" 20ft '""" TABLE 12: Special Districts. The metrics for each column of this table (SD1, SD2, etc.) are to be filled in for each Special district as they are permitted pursuant to a Regulating Plan or Special Area Plan.

Functions may be specifically listed or may reference an existing City of Kennesaw zoning district.

More pages can be added. Special Districts that do not have provisions noted herein shall be governed by the standards of any other City of Kennesaw zoning district as set forth in Sections 1.4.4 (c) or (d), as applicable.

SD1 SD2 SD3 SD4 SD5 SD6 SD7

a. RESIDENTIAL DENSITY

By Right

b. BLOCK SIZE

Block Perimeter

c. THOROUGHFARES

HW BV AV CS DR ST RD Rear Lane Rear Alley Path Passage Multi-Use Trail Bicycle Lane Bicycle Route

d. CIVIC SPACES

Park Green Square Plaza Playground

e. LOT OCCUPATION

BUILDING PLACEMENT

Lot Width Lot Coverage

f. SETBACKS - PRINCIPAL BUILDING

Front Setback Side Setback Rear Setback Frontage Buildout

g. BUILDING PLACEMENT

Edgeyard Sideyard Rearyard Courtyard

SD1 SD2 SD3 SD4 SD5 SD6 SD7

h. PRIVATE FRONTAGES

BUILDING FORM

Common Yard Porch & Fence Terrace, Dooryard Forecourt Stoop Shopfront Gallery Arcade Open Parking

i. BUILDING FORM - HEIGHT

Principal Building Outbuilding

j. BUILDING FUNCTION

FUNCTION

Residential Lodging Office Retail (Ord. No. 2016-03, Att., 3-7-16) TABLE 13: Definitions Illustrated

a. THOROUGHFARE & FRONTAGES

b. TURNING RADIUS c. BUILDING DISPOSITION

d. LOT LAYERS e. FRONTAGE & LOT LINES

Building Private Loi I i i i i i ll""' I j ·--·-·-·--·--- ·-~ Pnvate Fronlage I I I I ~ I~ rg, I 8' ~/ j / I Pubhc [ +Frontage 1-Radlus al lhe Curb v:r IF~~I Thoroughfare (R.O.W.) + Pnvate Frontage Private Lot 1 • Principal Building 2- Backbu11d1ng 3- Outbuilding 2-Effedlve Tumo,g Radius(: 8 ft) ·-·-·-·-·-·-·~·-·-·-·-·-·-·, i I ! 3rdla~r 2nd layer ·- ·- ·- ·- ·-- ·- ·.1.

~-·- ·- ·- ·- Isl layer ··-·-·-·-·- ·-·r-·- ·- ·- -- -- ·""' 4 ! 4 : I I i j ~ '1 4 4 ! 4 ! : !

i !

i !

3 i 3 :

-·-·-· ·-·-·-·i._. _________ j 1-Frontage line 2-LolLme 3-Facades 4-Elevabons

f. SETBACK DESIGNATIONS

(Ord. No. 2016-03, Att., 3-7-16)

APPENDIX A—UNIFIED DEVELOPMENT CODE Art. 5 1-flO!lt Setback

2-S1de Setback 3-Rear Setback

Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.