(a) Tree density standards. A basic requirement of this chapter is that all applicable sites, with the exception of sites within the DT-MX zoning district, shall maintain or exceed a minimum tree density as follows: (1) New development. a. Subdivisions including all residential dwelling uses except for multi-family dwelling uses. Six (6) tree density units per acre calculated based on the defined limits of construction of roads, utilities, detention ponds, etc. The minimum tree density shall be met in common areas of the subdivision, including, but not limited to, areas such as parks, active and passive recreation areas, and subdivision entrances. b. Individual lots for residential dwelling uses except for multi-family dwelling uses. A minimum of two (2) trees per lot with a minimum of one (1) such tree located within the front yard. Prior to final plat approval, the director shall confirm that the trees required by the applicable zoning district have been provided. c. For all industrial uses: Three (3) tree density units per acre. d. All other uses: Six (6) tree density units per acre. (2) Redevelopment. Redevelopment of multi-family dwelling uses and nonresidential uses shall require compliance with the tree density standard for new development in subsection (a) above. For the purposes of this section, redevelopment is defined as one (1) or more of the following: a. Demolition of an existing building and rebuilding on the site; b. Expansion of the gross square feet of the impervious surface on the site by more than fifty (50) percent. c. Expansions and additions to multi-family dwellings and nonresidential uses. When expansion of a site equals no more than fifty (50) percent of the pre-existing impervious surface gross square footage, the tree density standard shall be required and calculated based on the amount of disturbed area for the expansion. Expansion by more than fifty (50) percent of the existing impervious surface gross square feet shall be considered redevelopment and subject to the requirements of subsection (a)(2) above. (b) The term "unit" is not synonymous with "tree." The density requirement must be met whether or not a site had trees prior to development and may be achieved by counting existing trees to be preserved, planting new trees in accordance with the minimum standards of this chapter, or some combination of the two (2) as represented by the formula: SDF = EDF + RDF Where: SDF (site density factor) = The minimum tree density required to be maintained on a developed site shall be three (3) units per acre for all industrial uses and (six (6) units per acre for all other uses. EDF (existing density factor) = Density of existing trees to be preserved on a site. RDF (replacement density factor) = Density of new trees to be planted on a site. (c) The site density factor (SDF) is calculated by multiplying the number of site acres by three (3) for industrial uses and six (6) for all other uses. Example: A 3.5 acre commercial site has a SDF of 3.5 X 6 = 21. (d) The existing density factor (EDF) is calculated by converting the diameter of individual trees to density factor units. This is done using Table A below. Only trees included on the city's approved tree list can be counted in determining the EDF of the site, unless the city authorizes the use of substitute trees subject to the approval of the tree board. Table A. Credit for Existing Trees (EDF)\ Conversion from Tree DBH in Inches to Tree Density Units for Trees Remaining on Site | | | | | | | | | |-----|-------|-----|-------|-----|-------|-----|-------| | DBH | Units | DBH | Units | DBH | Units | DBH | Units | | 3″ | 0.1 | 15″ | 1.2 | 27″ | 4.0 | 39″ | 8.3 | | 4″ | 0.1 | 16″ | 1.4 | 28″ | 4.3 | 40″ | 8.7 | | 5″ | 0.2 | 17″ | 1.6 | 29″ | 4.6 | 41″ | 9.2 | | 6″ | 0.2 | 18″ | 1.8 | 30″ | 4.9 | 42″ | 9.6 | | 7″ | 0.3 | 19″ | 2.0 | 31″ | 5.2 | 43″ | 10.1 | | 8″ | 0.4 | 20″ | 2.2 | 32″ | 5.6 | 44″ | 10.6 | | 9″ | 0.5 | 21″ | 2.4 | 33″ | 5.9 | 45″ | 11.0 | | 10″ | 0.6 | 22″ | 2.6 | 34″ | 6.3 | 46″ | 11.5 | | 11″ | 0.7 | 23″ | 2.9 | 35″ | 6.7 | 47″ | 12.0 | | 12″ | 0.8 | 24″ | 3.1 | 36″ | 7.1 | 48″ | 12.6 | | 13″ | 0.9 | 25″ | 3.4 | 37″ | 7.5 | 49″ | 13.1 | | 14″ | 1.1 | 26″ | 3.7 | 38″ | 7.9 | 50″ | 13.6 | Note: DBH is rounded to the nearest inch (0.5 and higher is rounded up to next inch, 0.4 and lower is rounded down). Example: A total of twelve (12) trees will remain on the three and one-half (3½) acre site. The tree inventory is as follows: 7—12″ DBH maples 3—18″ DBH pines 1—21″ DBH oak 1—24″ DBH oak Converting DBH to density units, the EDF is determined as shown in the following table: | | | | | | | | |-----------------|------------------|-----|-------|-----|-----------------|-------| | Scientific Name | Common Name | DBH | Units | X | Number of Trees | Total | | Acer barbatum | Florida Maple | 12″ | 0.8 | X | 7 | = 5.6 | | Pinus palustris | Longleaf Pine | 18″ | 1.8 | X | 3 | = 5.4 | | Quercus alba | White Oak | 21″ | 2.4 | X | 1 | = 2.4 | | Quercus falcate | Southern Red Oak | 24″ | 3.1 | X | 1 | = 3.1 | | | | | | | | 16.5 | (e) Calculate the replacement density factor (RDF) by subtracting the EDF from the SDF. Example: RDF = 21 - 16.5 = 4.5. The density factor credit for each caliper size of replacement (new) trees is shown in Table B. Any number or combination of transplantable size trees can be used so long as their total density factor units will equal or exceed the RDF and their species is selected from the city approved tree list. If it has been determined by the director that the property in question is completely barren of trees and has been for more than ten (10) years (i.e. pasture land), then the unit value for each replacement tree planted will be doubled. Table B — Credit for Replacement Trees (RDF)\ Conversion from Tree Caliper in Inches to Tree Density Units\ for Proposed Replacement Trees | | | | | |---------|-------|---------|-------| | Caliper | Units | Caliper | Units | | 1.5″ | 0.4 | 8″ | 1.3 | | 2″ | 0.5 | 9″ | 1.5 | | 3″ | 0.6 | 10″ | 1.7 | | 4″ | 0.7 | 11″ | 1.9 | | 5″ | 0.9 | 12″ | 2.1 | | 6″ | 1.0 | 13″ | 2.3 | | 7″ | 1.2 | 14″ | 2.5 | Note: For the purposes of this chapter, tree calipers are measured at one and one-half (1½) feet above the ground or at any point below that for new trees or multi-trunked species, but in no case less than six (6) inches from the ground. (f) Buffer exclusion. Existing trees proposed to be retained and new trees proposed to be planted in order to meet the buffer requirements of this article or conditions of zoning, special use or variance approval shall not be considered in fulfilling the requirements of this article and do not count towards meeting the tree density requirement. As such, properties containing required buffers may exclude the land area contained in those buffers from the total acreage of the property in calculating the site density factor of this article. (g) Easement exclusion. Properties possessing natural gas, petroleum or electric power transmission easements, or sanitary sewer main (greater than eight (8) inches in diameter) or water main (greater than sixteen (16) inches in diameter) distribution easements, may exclude the land area contained in said easement from the total acreage of the property in fulfilling the tree density standard of this article provided that no improvements (e.g. parking lots, tennis courts, driveways, stormwater detention facilities, etc.) are proposed within the easement. If any improvements are proposed within the easement, then the land area so utilized within the easement for the improvement, plus an additional ten (10) feet of land area surrounding the improvements, shall be used to fulfill the tree density standard of this article. (h) Lake and pond exclusion. Properties with an existing lake or pond may exclude the land area contained in the lake or pond from the total acreage of the property in calculating the site density factor.