Part II - CODE / Chapter 10 - BUILDINGS AND BUILDING REGULATIONS / Article VIII - MULTI-FAMILY RENTAL HOUSING
Sec. 10-305. Interior evaluations of multifamily rental units.
About this text
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
Interior evaluations will be conducted to ensure compliance with the International Property Maintenance Code (IPMC), the Life Safety Code (existing provisions) and the International Fire Code (IFC) and other referenced standards contained herein and, at a minimum, will include inspections of the following items. The 2018 International Property Maintenance Code (IPMC) and the 2018 International Fire Code (IFC), or the latest version of the same as approved and amended by the Georgia Department of Community Affairs, are the referenced codes.
(1) Apartment numbers identification posted in accordance with IPMC section 304.3.
Buildings shall have approved address numbers placed in a position to be plainly legible and visible from the public or private street or road fronting the multifamily dwelling unit. These numbers shall contrast with their background. Address numbers shall be Arabic numerals or alphabet letters. Numbers shall be a minimum of four inches (102 millimeters) high with a minimum stroke width of 0.5 inches (12.7 millimeters).
(2) Flooring shall be installed and maintained in accordance with IPMC 305.1.
(3) All interior surfaces, including windows and doors, shall be maintained in good, clean, and sanitary condition with no chipping or flaking paint or loose plaster, decayed wood and other defective surface conditions.
(4) Hot and cold water at kitchen baths and laundry rooms is provided in accordance with IPMC section 505.1. Every sink, lavatory, bathtub, or shower, drinking fountain, water closet or other plumbing fixture shall be properly connected to either a public water system or to an approved private water system. All kitchen sinks, lavatories, laundry facilities, bathtubs and showers shall be supplied with hot or tempered and cold running water in accordance with the International Plumbing Code.
(5) Privacy for bathrooms shall be provided in accordance with IPMC section 503.1.
Toilet rooms and bathrooms shall provide privacy and shall not constitute the only passageway to a hall or other space, or to the exterior. A door and interior locking device shall be provided for all common or shared bathrooms and toilet rooms in a multiple dwelling.
(6) Heating facilities are in good working order in accordance with IPMC section 602.2 and 603.1. No unvented heating appliances in sleeping rooms. Dwellings shall be provided with heating facilities capable of maintaining a room temperature of 68 degrees Fahrenheit (20 degrees Celsius) in all habitable rooms, bathrooms and toilet rooms based on the winter outdoor design temperature for the locality indicated in appendix D of the International Plumbing Code. Cooking appliances shall not be used to provide space heating to meet the requirements of this section (603.1). All mechanical equipment, appliances, fireplaces, solid fuel-burning appliances, cooking appliances and water heating appliances shall be properly installed and maintained in a safe working condition and shall be capable of performing the intended function.
(7) Garbage disposal facilities are in accordance with IPMC section 308. Every occupant of a structure shall dispose of garbage in a clean and sanitary manner by placing such garbage in an approved garbage disposal facility or approved garbage containers. (IPMC 308.3) The owner of every dwelling shall supply one of the following: an approved mechanical food waste grinder in each multifamily rental unit; an approved incinerator unit in the structure available to the occupants in each multifamily dwelling unit; or an approved leak-proof, covered, outside garbage container. (IPMC 308.3.1) The owner of every multifamily rental unit producing garbage shall provide, and at all times cause to be utilized, approved leak-proof containers provided with close-fitting covers for the storage of such materials until removed from the premises for disposal.
(8) Smoke detector devices shall be provided in accordance with IPMC section 704.6.1.2.
Single or multiple-station smoke alarms shall be installed and maintained in groups R-2, R-3, R-4 and in dwellings not regulated in group R occupancies, regardless of occupant load at all of the following locations:
a. On the ceiling or wall outside of each separate sleeping area in the immediate vicinity of bedrooms.
b. In each room used for sleeping purposes.
c. In each story within a dwelling unit, including basements and cellars but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with split levels and without an intervening door between the adjacent levels, a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level.
d. Single or multiple-station smoke alarms shall be installed in other groups in accordance with the International Fire Code.
e. Per O.C.G.A. § 25-2-40.
f. For multifamily rental units constructed before 1987: at least one battery operated between the living and sleeping areas.
g. Unless over three or more stories, detectors shall be installed within each multifamily rental unit between living and sleeping areas. Such detectors shall be continuously powered by the building's electrical system. When activated, the detector shall initiate an alarm which is audible in sleeping rooms of that living unit.
h. For multifamily rental units constructed after 1987, detectors must be located on every level and outside of the sleeping area.
i. For multifamily rental units constructed after 2007, detectors must be installed per IPMC including one on every level, outside of the sleeping area and inside of every sleeping room.
(9) Window spaces for light, ventilation, operable and emergency escape shall conform with IPMC sections 304.13.1, 304.13.2, 304.14, 304.18.2, 402.1 and 702.4. (304.13.1) All glazing materials shall be maintained free from cracks and holes. (304.13.2) Every window, other than a fixed window, shall be easily openable and capable of being held in position by window hardware. (304.14) During the period from April 1 to October 1, every door, window, and other outside opening required for ventilation of habitable rooms, food preparation areas, or stored shall be supplied with approved tightly fitting screens of not less than 16 mesh per inch (16 mesh per 25 millimeters), and every screen door used for insect control shall have a self-closing device in good working condition. (304.18.2) Operable windows located in whole or in part within six feet (1,828 millimeters) above ground level or a walking surface below that provide access to a dwelling unit, rooming unit or housekeeping unit that is rented, leased, or let shall be equipped with a window sash locking device. (402.1) Every habitable space shall have at least one window of approved size facing directly to the outdoors or to a court. The minimum total glazed area for every habitable space shall be eight percent of the floor area of such room. Wherever walls or other portions of a structure face a window of any room and such obstructions are located less than three feet (914 millimeters) from the exterior of the window and extend to a level above that of the ceiling of the room, such window shall not be deemed to face directly to the outdoors nor to a court and shall not be included as contributing to the required minimum total window area for the room. (702.4) Required emergency escape openings shall be maintained in accordance with the code in effect at the time of construction, and the following: (i) required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools; (ii) bars, grilles, grates or similar devices are permitted to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the escape and rescue opening.
(10) Plumbing facilities to be maintained in a safe working condition in accordance with IPMC section 502.1. Every multifamily rental unit shall contain its own bathtub or shower, lavatory, water closet and kitchen sink which shall be maintained in a safe, sanitary, working condition. The lavatory shall be placed in the same room as the water closet or located in close proximity to the door leading directly into the room in which such water closet is located. A kitchen sink shall not be used as a substitute for the required lavatory.
(11) Electrical devices, service equipment and luminaries are in safe working condition with no exposed wires in accordance with IPMC sections 604 and 605. Every occupied building shall be provided with an electrical system in compliance with the requirements of this section and IPMC section 605. Multifamily rental units shall be served by a three-wire, 120/240 volt, single-phase electrical service having a rating of not less than 60 amperes. Where it is found that the electrical system in a structure constitutes a hazard to the occupants or the structure by reason of inadequate service, improper fusing, improper wiring or installation, deterioration, or damage, or for similar reasons, the defects are to be corrected to eliminate the hazard. (IPMC
605) All electrical equipment, wiring and appliances shall be properly installed and maintained in a safe and approved manner.
Every habitable space in a dwelling shall contain at least two separate and remote receptacle outlets. Every laundry area shall contain at least one grounded-type receptacle or a receptacle with a ground fault circuit interrupter. Every bathroom shall contain at least one receptacle. Every public hall, interior stairway, toilet room, kitchen, bathroom, bedroom, laundry room, boiler room and furnace room shall contain at least one electric luminaire. GFCI devices are provided in required locations dependent on the time of construction, repair, or remodel generally in accordance with the following standards:
a. 1971 Receptacles within 15 feet of pool walls.
b. 1973 All outdoor receptacles.
c. 1975 Bathrooms, 120-volt pool lights, and fountain equipment.
d. 1978 Garage receptacles.
e. 1981 Whirlpools and tubs.
f. 1984 Distance of GFCI protection extended to 20 feet from pool walls.
g. 1987 Unfinished basements.
h. 1987 Kitchen countertop receptacles within six feet of sink.
i. 1990 Crawlspaces (with exception for sump pumps or other dedicated equipment).
j. 1993 Wet bar countertops within six feet of sink.
k. 1993 Any receptacle replaced in an area presently requiring GFCI.
l. 1996 All kitchen counters—not just those within six feet of sink.
m. 2005 Receptacles near laundry and utility sinks within six feet.
(12) Door units, jambs and hardware are in good working order in accordance with IPMC sections 304.13, 304.18, 305.3 and 305.6 and required opening protective devices be maintained in an operative condition. In accordance with IPMC section 703.2 (IPMC 304.13), every window, skylight, door, and frame shall be kept in sound condition, good repair, and weather tight. (IPMC 304.18) Doors, windows or hatchways for dwelling units, room units or housekeeping units shall be provided with devices designed to provide security for the occupants and property within. (IPMC 305.3) All interior surfaces, including windows and doors, shall be maintained in good condition. Loose plaster and decayed wood shall be corrected. (IPMC 305.6) Every interior door shall fit reasonably well within its frame and shall be capable of being opened and closed by being properly and securely attached to jambs, headers or tracks as intended by the manufacturer of the attachment hardware. (IPMC 703.4) Required opening protectives shall be maintained in an operative condition. All fire and smoke-stop doors shall be maintained in operable condition. Fire doors and smoke barrier doors shall not be blocked or obstructed or otherwise made inoperable.
(13) Interior stairs, handrails and guards are maintained in a sound condition and good repair in accordance with IPMC sections 305.4, 305.5, and 306.1. (305.4) Every stair, ramp, landing, balcony, porch, deck, or other walking surface shall be maintained in sound condition and good repair. (IPMC 305.5) Every handrail and guard shall be firmly fastened and capable of supporting normally imposed loads and shall be maintained in good condition and repair. Every exterior and interior flight of stairs having more than four risers shall have a handrail on one side of the stair and every open portion of a stair, landing, balcony, porch, deck, ramp, or other walking surface which is more than 30 inches (762 millimeters) above the floor or grade below shall have handrails. Handrails shall not be less than 30 inches (762 millimeters) high or more than 42 inches (1,067 millimeters) high measured vertically above the nosing of the tread or above the finished floor of the landing or walking surfaces.
(14) Interior floors, walls and ceilings are maintained in good repair, structurally sound and in sanitary condition in accordance with IPMC section 305. The interior of a structure and equipment therein shall be maintained in good repair, structurally sound and in a sanitary condition. Occupants shall keep that part of the structure which they occupy or control in a clean and sanitary condition. (IPMC section 305) All structural members shall be maintained structurally sound and be capable of supporting the imposed loads. Defective surface conditions shall be corrected. (IPMC 306.1.1) Every stair, ramp, landing, balcony, porch, deck, or other walking surface shall be maintained in sound condition.
(15) Occupancy limitations per bedroom in accordance with IPMC section 404. Dwelling units, hotel units, housekeeping units, rooming units and dormitory units shall be arranged to provide privacy and be separate from other adjoining spaces. A habitable room, other than a kitchen, shall not be less than seven feet (2,134 millimeters) in any plan dimension. Kitchens shall have a clear passageway of not less than three feet (914 millimeters) between counter fronts and appliances or counter fronts and walls. Habitable spaces, hallways, corridors, laundry areas, bathrooms, toilet rooms and habitable basement areas shall have a clear ceiling height of not less than seven feet (2,134 millimeters).
a. Every bedroom shall comply with the requirements of IPMC sections 404.4.1 through 404.4.5.
b. Area for sleeping purposes. Every bedroom occupied by one person shall contain at least 70 square feet (6.5 square meters) of floor area, and every bedroom occupied by more than one person shall contain at least 50 square feet (4.6 square meters) of additional floor area for each occupant thereof (IPMC 404.4.1).
c. Access from bedrooms. Bedrooms shall not constitute the only means of access to other bedrooms or habitable spaces and shall not serve as the only means of egress from other habitable spaces. Exception: units that contain fewer than two bedrooms. (IPMC 404.4.2).
d. Every bedroom shall have access to at least one water closet and one lavatory without passing through another bedroom. Every bedroom in a dwelling unit shall have access to at least one water closet and lavatory located in the same story as the bedroom or an adjacent story.
e. Kitchens and non-habitable spaces shall not be used for sleeping purposes.
(IPMC 404.4.4).
f. Bedrooms shall comply with the applicable provisions of this code including, but not limited to, the light, ventilation, room area, ceiling height and room width requirements of the International Property Maintenance Code.
g. Multifamily rental units shall not be occupied by more occupants than permitted by the minimum area requirements found in IPMC section 404.5.
(16) Insect and rodent infestation in accordance with IPMC section 309.1. All structures shall be kept free from insect and rodent infestation. All structures in which insects or rodents are found shall be promptly exterminated by approved processes that will not be injurious to human health. After pest elimination, proper precautions shall be taken to prevent reinfestation.
(17) Means of egress shall be provided in accordance with IPMC section 702. A safe, continuous, and unobstructed path of travel shall be provided from any point in a building or structure to the public way. Means of egress shall comply with the International Fire Code. The required width of aisles in accordance with the International Fire Code shall be unobstructed. All means of egress doors shall be readily openable from the side from which egress is to be made without the need for keys, special knowledge, or effort, except where the door hardware conforms to that permitted by the International Building Code. Required emergency escape openings shall be maintained in accordance with the code in effect at the time of construction, and the following. Required emergency escape and rescue openings shall be operational from the inside of the room without the use of keys or tools. Bars, grilles, grates or similar devices are permitted to be placed over emergency escape and rescue openings provided the minimum net clear opening size complies with the code that was in effect at the time of construction and such devices shall be releasable or removable from the inside without the use of a key, tool or force greater than that which is required for normal operation of the escape and rescue opening.
(18) Fire extinguisher shall be present and tagged or inspection current in accordance with IFC 906.1 and NFPA 10 (906.1). Portable fire extinguishers shall be installed in the following locations: (1.) In new and existing group A, B, E, F, H, I, M, R-1, R-2, R-4 and S occupancies and; (2.) (NFPA 10) Fire extinguishers must be within 75-foot travel distance of the most remote location of a dwelling. (906.2) Portable fire extinguishers shall be selected, installed, and maintained in accordance with this section and NFPA 10.
(19) Sprinkler heads clear and unobstructed. NFPA 25 Sprinkler heads must be free from dust, debris, paint, and obstructions that would otherwise inhibit their operation.