(a) Plan view shall show the following: (1) Label and show all existing contours at a maximum two-foot interval; (2) Label and show all proposed contours at a maximum one-foot interval; (3) Show ditch contours as grade slope indicators with spot elevations; (4) Grade work to be shown by contours or grade slope indicators; (5) Road pavement and/or curb and gutter edges; (6) Right-of-way limits; (7) Easements and building setbacks; (8) All storm system structures; (9) Detail construction information about storm system such as inverts, pipe size, grade, type of pipe, number of inlets, amount of rip-rap (length and width dimensions); (10) Water lines and associated structures; (11) Sanitary sewer lines and associated structures; (12) Station numbers on the roadway; (13) Survey information about alignment and horizontal curves; and (14) Stations display at least every 100-foot interval. (b) Profile view shall show the following: (1) Survey information about roadway grade and vertical curves; (2) Existing centerline elevations; (3) Proposed centerline elevations; (4) Station numbers; (5) Base elevations; (6) Any pipe crossings; (7) Stations display at least every 100-foot interval; and (8) Transition locations such as end of pavement, beginning of curb, intersection with other roads, etc.