(a) Reference markers. (1) At least one corner of the subdivision shall be designated by course and distance from a readily discernable reference marker such as a lot intersection marker or the intersection of two existing streets. If a corner lies within 500 feet of triangulation or traverse station of the state coordinate system this corner shall be marked with a monument so designated by computer X and Y coordinates which shall also appear on the map with a statement identifying the location of this station or monument to an accuracy of 1:10,000. (2) All other intersections and lot corners shall be marked with iron pipes not less than three-fourths inch in diameter or iron rebar not less than one-half inch in diameter. Both marker types shall be not less than 24 inches long and driven so as to be flush with the finished grade. The above standards shall also apply to any revision or addition to an existing subdivision. (3) The lots shall be marked in the field by the appropriate number as shown on the proposed subdivision plat. Such marking shall be in the form of stakes along each street front property corner. (b) Lot layout. (1) Side lot lines shall be as perpendicular to the right-of-way tangent as possible. In no circumstances shall the angle between the side lot line and the right-of-way tangent be less than 70 degrees. (2) The lot arrangement shall be such that there shall be no foreseeable difficulties, for reasons of topography or other conditions, in securing building permits to build on all lots in compliance with the county's ordinances and in providing driveway access to buildings on such lots from an approved public street.