(a) General inlet design criteria. (1) Design and spacing requirements governing the street drainage collection system shall prevent ponding, overflow, and flooding of streets and intersections; remove runoff from surfaces where the flows exceed the criteria for flow and velocity; and shall provide for proper maintenance. Given these functions, the street drainage collection system shall locate inlets at low points and at other points required for proper drainage and inlets should be placed where they can efficiently intercept and capture water flow. The safety of the traveling public must also be addressed in the proposed design. (2) All inlet grates shall be designed to avoid blockage by debris and to address bicycle and pedestrian safety. (3) Locating curb inlets in the radius of intersections or driveways is not recommended and such shall be avoided if possible. (4) Street drainage shall not flow through an intersection by means of crossing the roadway. Street drainage is allowed to follow the intersection radius though this is not recommended and shall be avoided if possible. (b) Pipe design. (1) The minimum pipe size to be a component part of a public storm drainage system shall be 18 inches in diameter. (2) A manhole, junction box, or inlet shall be constructed at any point where the storm pipe has additional runoff added, has another pipe joining it, or has changed direction, grade, size, or alignment. The maximum length of storm sewer pipe between such structures shall be as follows. Pipe diameter (inches) Structure spacing (feet) 15 and less 500 18 to 36 600 42 to 60 700 Pipe diameter (inches) Structure spacing (feet) Greater than 60 case by case as needed (3) Headwalls, headwalls with wing walls, sloped paved headwalls, or flared end section shall be constructed at both ends of the pipe, except where beginning or terminating in a manhole or inlet structure. This requirement applies only to pipes located with county, state, or federal rights-of-way, easements or other lands. (4) Pipe cover, compaction requirements and pipe type for storm pipes: Under or within five feet of street pavement Minimum pipe cover Backfill required Pipe type required 0 to 4 inches Not allowed Not allowed 4 to 71 /2 inches Concrete RCP 71 /2 to 30 inches 95% may require RCP 30 to 120 inches 95% spot check RCP, AP, CMP, PP Greater than 120 inches 95% may require RCP, (AP, CMP w/weight check) In county easements, rights-of-way or other lands but not under pavement Minimum pipe cover Backfill required Pipe type required 0 to 120 inches 85% spot check RCP, AP, PP, CMP Greater than 120 inches 85% may require RCP, AP, PP, CMP a. Definitions: Pipe cover means distance from the top of pavement to outside top of pipe, centerline and pavement edges checked. b. Backfill required: 1. Concrete: Lean concrete (2,000 psi) placed one-half pipe diameter to top of base material. 2. Eighty-five percent or 95 percent may [be] required: May require test results (showing compliance) to be given to the manager of development services at his discretion, requires backfill to meet 85 percent or 95 percent of maximum density as determined by AASHTO T-99 (gravel may be used as an alternate to soil backfill no testing required). 3. Eighty-five percent or 95 percent spot check: Only in adverse situations shall test results (showing compliance) be required to be given to the manager of development services at his discretion, requires backfill to meet 85 percent or 95 percent of maximum density as determined by AASHTO T-99. c. Pipe type: 1. RCP: Reinforced concrete pipe, class III, meeting state department of transportation specifications. 2. AP: Corrugated, smooth lines, or structural plate aluminum pipe, meeting state department of transportation specifications. 3. PP: Corrugated, smooth lined, or truss plastic pipe, reviewed on case by case basis with reference to state department of transportation specifications. 4. CMP: Corrugated, smooth lined, or structural plate steel pipe that meets state departments of transportation specifications. 5. Design life (in respect to corrosion, abrasion, weathering... etc.) of pipes is 50 years. Construction plans using metal and/or plastic pipes must provide information proving the design life is met. Standard tar coating for metal pipes shall not be considered as part of the protection. The procedure to determine adequacy shall be from the U.S. Army Corps of Engineers' publication Life Cycle Cost for Drainage Structures Technical Report GL-88-2. 6. Safety grates shall be applied to all "inlet" and "outlet" pipe ends when pipe is greater than 36 inches inside diameter and is a roadway cross drain pipe. 7. Energy dissipater devices are required at ends of all pipe outlets. d. Open ditch design. Design shall typically conform to the following: 1. Design of open ditches shall be from the Georgia Storm Water Manual Volume 2. 2. In those cases where the grade of the ditch causes drainage water to exceed the ditch's erosive velocity limit, the ditch shall be lined with a suitable lining to prevent erosion. Such appropriate linings include concrete, suitable pavement, sod, or jute mesh. Ditch erosive velocity limits are listed in "Maximum Permissible Velocities in Vegetal-lines Channels." Federal Highway Administration, Hydraulic Engineering Circular #15 (HEC-15), and Vegetated Water or StormWater Conveyance Channel, Chapter 6, Manual for Erosion and Sediment Control in Georgia. 3. Drainage ditches shall be a minimum of two feet in width at the bottom and the sides shall be constructed to a slope of 4H:1V. 4. Design stormwater depth not to exceed two and one-half feet unless access is limited to it, such as by fencing.