--- title: Lee County Zoning Ordinance, Sec. 38-305. Overbank flooding protection collection: local-codes id: local-code:lee-county/zoning/38-305 cite_as: Lee County, Ga., Zoning Ordinance ยง 38-305 canonical_url: https://georgiacommons.org/code/local/lee-county/zoning/38-305 md_url: https://georgiacommons.org/code/local/lee-county/zoning/38-305.md text_url: https://georgiacommons.org/code/local/lee-county/zoning/38-305/text source_url: https://library.municode.com/ga/lee_county/codes/code_of_ordinances date: 2026-06-23 status: active jurisdiction: county:lee jurisdiction_name: Lee County county_fips: "13177" corpus_version: local-codes-lee-county-30354395a313 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/lee-county/zoning/~part-ii/~chapter-38/~article-vii/~division-3.md previous: https://georgiacommons.org/code/local/lee-county/zoning/38-304.md next: https://georgiacommons.org/code/local/lee-county/zoning/38-306.md index: https://georgiacommons.org/code/local/lee-county.md branch: zoning edition: As published by Municode, current through 2026-06-23 edition_date_kind: current_through source_publisher: Municode version_id: local-code:lee-county/zoning/38-305@2026-06-23-f865475fed --- # Lee County Zoning Ordinance, Sec. 38-305. Overbank flooding protection > As published by Municode, current through 2026-06-23 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 38 - LAND DEVELOPMENT CODE / Article VII - STORM DRAINAGE SYSTEMS / Division 3 - POST DEVELOPMENT STORMWATER MANAGEMENT Downstream overbank flood and property protection shall be provided by controlling (attenuating) the post-development peak discharge rate to the pre-development rate for the 25-year, 24-hour return frequency storm event. If control of the one-year, 24-hour storm under section 4.2 is exempted, then peak discharge rate attenuation of the two-year through the 25-year return frequency storm event must be provided. (1) This requirement may be adjusted or waived by the development services director or his designee for sites where the post-development downstream analysis shows that uncontrolled post-development conditions will not increase downstream peak flows, or that meeting the requirement will cause greater peak flow downstream impacts than the uncontrolled post-development conditions. ## History (Res. No. LD05-A049, 9-23-2005)