--- title: Lee County Zoning Ordinance, Sec. 38-482. Sewerage system design criteria collection: local-codes id: local-code:lee-county/zoning/38-482 cite_as: Lee County, Ga., Zoning Ordinance § 38-482 canonical_url: https://georgiacommons.org/code/local/lee-county/zoning/38-482 md_url: https://georgiacommons.org/code/local/lee-county/zoning/38-482.md text_url: https://georgiacommons.org/code/local/lee-county/zoning/38-482/text source_url: https://library.municode.com/ga/lee_county/codes/code_of_ordinances date: 2026-06-23 status: active jurisdiction: county:lee jurisdiction_name: Lee County county_fips: "13177" corpus_version: local-codes-lee-county-30354395a313 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/lee-county/zoning/~part-ii/~chapter-38/~article-xi/~division-1.md previous: https://georgiacommons.org/code/local/lee-county/zoning/38-481.md next: https://georgiacommons.org/code/local/lee-county/zoning/38-483.md index: https://georgiacommons.org/code/local/lee-county.md branch: zoning edition: As published by Municode, current through 2026-06-23 edition_date_kind: current_through source_publisher: Municode version_id: local-code:lee-county/zoning/38-482@2026-06-23-4bd6d3e609 --- # Lee County Zoning Ordinance, Sec. 38-482. Sewerage system design criteria > As published by Municode, current through 2026-06-23 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 38 - LAND DEVELOPMENT CODE / Article XI - SANITARY SEWAGE REQUIREMENTS / Division 1 - GENERALLY (a) Sanitary sewer stub-outs shall be provided for each development lot and shall extend from the sewer line to the property line if public sanitary sewer service is provided in the development. (b) No sanitary sewer shall be allowed to connect to any storm drainage pipes or systems. (c) Sanitary sewer velocities shall be sufficient to prevent deposition, yet not high enough to cause separation or cause erosive damage to the pipe. In order to accomplish this sewers shall be sloped to achieve a minimum velocity of two feet per second when the conduit is flowing half full. The slope shall also be designed so that the velocity will not exceed ten feet per second. The required slope to achieve minimum velocity (n = 0.13) shall be: Pipe size (inches) Slope (foot/100 feet) 8 0.40 10 0.28 12 0.22 15 0.15 18 0.12 21 0.10 24 0.08 27 0.07 30 0.06 (d) Infiltration into the sewer shall not exceed 200 gallons per minute per mile of sewer per inch of inside diameter of pipe per 24 hours in any section between successive manholes. In areas where the seasonal or normal groundwater is above the top of the pipe, the plans are to be noted as such and special conditions may be placed on those pipes. ## History (Ord. of 9-18-00(2), § 38-482)