(a) Plan view shall show the following: (1) Label and show all existing contours at a maximum two-foot interval; (2) Label and show all proposed contours at a maximum one-foot interval; (3) All grade work to be shown by contours or grade slope indicators; (4) Road pavement and/or curb and gutter edges; (5) Right-of-way limits; (6) Easements, minimum building front and rear setbacks, if applicable; (7) If crossing is made with storm sewer system then show detail construction information about storm system such as inverts, pipe size, grade, type of pipe, number of inlets, amount of rip-rap (length and width dimensions); (8) If crossing water lines and structures show elevations of such; (9) Sewer lines, structures, alignment and related information such as elevations, grades, pipe size and type, inverts, stations of structures, etc.; (10) Station numbers; and (11) Stations display at least at 100-foot intervals. (b) Profile view shall show the following: (1) Existing contour elevations; (2) Sewer line information; (3) Station numbers; (4) Base elevations; (5) Any pipe crossings; (6) Stations display at 100-foot intervals; and (7) Transition locations.