--- title: Leesburg Zoning Ordinance, Sec. 10.03 (Appendix C, Article X, Division 1). Water line design criteria collection: local-codes id: local-code:leesburg/zoning/appendix-c-article-x-division-1-10.03 cite_as: Leesburg, Ga., Zoning Ordinance, Appendix C, Article X, Division 1, ยง 10.03 canonical_url: https://georgiacommons.org/code/local/leesburg/zoning/appendix-c-article-x-division-1-10.03 md_url: https://georgiacommons.org/code/local/leesburg/zoning/appendix-c-article-x-division-1-10.03.md text_url: https://georgiacommons.org/code/local/leesburg/zoning/appendix-c-article-x-division-1-10.03/text source_url: https://library.municode.com/ga/leesburg/codes/code_of_ordinances date: 2026-11-11 status: active jurisdiction: city:leesburg jurisdiction_name: Leesburg place_fips: "1345768" corpus_version: local-codes-leesburg-12e648c39c4a publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/leesburg/zoning/~appendix-c/~article-x/~division-1.md previous: https://georgiacommons.org/code/local/leesburg/zoning/appendix-c-article-x-division-1-10.02.md next: https://georgiacommons.org/code/local/leesburg/zoning/appendix-c-article-x-division-1-10.04.md index: https://georgiacommons.org/code/local/leesburg.md branch: zoning edition: As published by Municode, retrieved 2026-11-11 edition_date_kind: retrieved source_publisher: Municode version_id: local-code:leesburg/zoning/appendix-c-article-x-division-1-10.03@2026-11-11-38b6507499 --- # Leesburg Zoning Ordinance, Sec. 10.03 (Appendix C, Article X, Division 1). Water line design criteria > As published by Municode, retrieved 2026-11-11 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Appendix C - LAND DEVELOPMENT REGULATIONS / Article X - POTABLE WATER REQUIREMENTS / Division 1 - GENERALLY (a) Working pressure. All pipe, fittings, valves, fire hydrants and appurtenances shall be capable of full service at a working pressure of not less than 150 psi. (b) Pressure. All water mains including those not designed to provide fire protection, shall be sized after hydraulic analysis to maintain a minimum, in service pressure of 20 psi at ground level under all conditions of design flow. (c) Design flow. (1) The design flow is to consist of projected demand plus fire flow (if required). To determine projected peak flow for residential developments the values in Table 6.3A shall be used. For developments other than residential, utilize AWWA Manual of Water Supply Practices M22, Sizing Water Service Lines and Meters, to establish peak demand. For fire flow, select the proper value from Table 6.3B. (2) Any new water lines connected to a utilities authority water main with pressure supplied by an elevated tank shall be required to design for fire flow. Table 6.3A Peak Water Demand for Residential Developments Number of Dwelling Units Gallons per Minute per Dwelling Unit 5 8.0 10 5.0 20 4.3 30 3.8 40 3.4 50 3.0 60 2.7 70 2.5 80 2.2 90 2.1 100 2.0 150 1.6 200 1.3 300 1.2 400 0.9 500 0.8 750 0.7 1,000 0.6 Table 6.3B Minimum Design Fire Flows Zoning District Gallons per Minute R-1 750 R-2 1,000 R-3 750 C-1 750 C-2 1,000 I-1 1,250 I-2 1,250