--- title: Louisville Zoning Ordinance, Sec. 46-122. Manufactured home installation requirements collection: local-codes id: local-code:louisville/zoning/46-122 cite_as: Louisville, Ga., Zoning Ordinance § 46-122 canonical_url: https://georgiacommons.org/code/local/louisville/zoning/46-122 md_url: https://georgiacommons.org/code/local/louisville/zoning/46-122.md text_url: https://georgiacommons.org/code/local/louisville/zoning/46-122/text source_url: https://library.municode.com/ga/louisville date: 2026-11-11 status: active jurisdiction: city:louisville jurisdiction_name: Louisville place_fips: "1347560" corpus_version: local-codes-louisville-2ccf8d1811e2 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/louisville/zoning/~part-ii/~chapter-46/~article-iv/~division-1.md previous: https://georgiacommons.org/code/local/louisville/zoning/46-121.md next: https://georgiacommons.org/code/local/louisville/zoning/46-123.md index: https://georgiacommons.org/code/local/louisville.md branch: zoning edition: As published by Municode, retrieved 2026-11-11 edition_date_kind: retrieved source_publisher: Municode version_id: local-code:louisville/zoning/46-122@2026-11-11-e2beb309ba --- # Louisville Zoning Ordinance, Sec. 46-122. Manufactured home installation requirements > As published by Municode, retrieved 2026-11-11 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Part II - CODE OF ORDINANCES / Chapter 46 - ZONING / Article IV - MANUFACTURED HOUSING / Division 1 - GENERALLY (a) Utility connections. All manufactured homes must be permanently connected to water, sewerage and electrical service. (1) Water. Water service shall be public. Connection procedures must meet the most current Southern Standard Plumbing Code requirements and must be freeze-proof above and below ground. Water connection must be inspected and approved by the building official. (2) Sewer. Plumbing for sewerage or septic system must meet the Southern Standard Plumbing Code and any county health department requirements. The sewerage system must be inspected and approved by the building official. (3) Electrical. Electrical service must meet requirements of the most recent National Electrical Code. Electrical connection must be inspected and approved by the building official prior to authorization to the servicing power company to install permanent power service. (b) Foundation. All manufactured homes must be installed on a pier system, installed with permanent skirting, secured with tie down devices and provided with steps and landings. The installation of all required foundation requirements must be inspected and approved by the building official. (1) Pier system. Piers or load-bearing supports or devices shall be designed and constructed to evenly distribute the loads. Piers shall be securely attached to the frame of the manufactured home or shall extend at least six inches from the centerline of the frame member. Manufactured load-bearing supports or devices shall be listed or approved for the use intended, or piers shall be constructed as follows: a. Piers less than 40 inches in height shall be constructed of open or closed cell, eight-inch by eight-inch by 16-inch concrete blocks (with open cells vertically placed upon the footer). Single-stacked block piers shall be installed with the 16-inch dimensions perpendicular to the main (I-beam) frame. The piers shall be covered with a two-inch by eight-inch by 16-inch wood or concrete cap. b. Piers between 40 and 80 inches in height and all corner piers over three blocks high shall be double blocked with blocks interlocked and capped with a four-inch by 16-inch by 16-inch solid concrete block, or equivalent. c. Piers over 80 inches in height shall be constructed in accordance with subsection (b)(1) of this section and they shall be laid in concrete mortar and steel reinforcing bars inserted in block cells with the block cells filled with concrete. d. All piers shall be placed on footings of solid concrete not less than 16 inches by 16 inches by four inches. (2) Skirting. Installation of skirting shall be required. Installation shall be in accordance with the manufacturer's installation instructions. Acceptable materials may include masonry, stone or brick material for the purpose of skirting. (3) Tiedowns. Each manufactured home shall have tiedowns or other devices securing the stability of the manufactured home as per installation of manufactured homes and mobile homes rules and regulations established and published by state safety fire commissioner (O.C.G.A. § 8-2-160 et seq.). a. The requirements for units 14 feet and less in width require two types of anchorage: 1. Over-the-top tiedowns to restrict overturning; and 2. Frame tiedowns to restrict the unit from being pushed from its piers. b. The requirements for units over 14 feet in width ("double-wides") require frame tiedowns only. (4) Steps and landings. Steps and landings are required for all homes and shall be constructed to the standards set forth in chapter XI, section 1113 of the Stairway Construction of the Standard Building Code. (c) Recreational vehicles. Permanent connection of recreational vehicles to water, sewer or electrical service is prohibited. Installation of recreational vehicles on piers and jacks permanently is also prohibited. ## History (Ord. of 8-11-1998, § 7-7)