Lovejoy · Zoning Ordinance
Appendix A - ZONING / Article VIII - SCHEDULE OF DISTRICT REGULATIONS
Sec. 808. RD Residential Duplex.
About this text
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
This district is intended to provide locations for duplex structures, where public water and public sewer are available.
808.1. Development standards for RD district.
Minimum zoning district Minimum 14,520 square feet to a maximum of 2 acres Minimum lot area 14,520 square feet Minimum lot width 100 feet Minimum setbacks Front: 30 feet Side: 10 feet Rear: 30 feet Maximum height 35 feet Minimum house size (heated space) 1,100 square feet per unit Paved driveway Yes; minimum eight feet wide per unit Garage Minimum one-car plus one additional space.
See section 808.2(F) Sewage system Public sewer Water system Public water
808.2. Building standards for RD district. All principal structures within RD district shall meet the following:
A) Building facades constructed of cement fiber board, brick, stone, or masonry product only, no vinyl siding. Vinyl may be used only for eaves and soffits.
B) Gutters requirement on all primary structures.
C) Minimum of 12-inch building overhang on all structures.
D) The dwelling shall be attached to a permanent foundation. The foundation shall be concrete or masonry blocks joined by mortar or both.
E) Any building having its finished floor entirely above grade, except for a basement, as defined in the International Building Code, shall be enclosed by masonry blocks or bricks joined by mortar or poured concrete walls having a height of at least 18 inches and a minimum width of six inches wide.
F) Garage requirements per above development standards shall meet minimum width requirements, two-car garage minimum width is 16 feet and one-car garage minimum width is ten feet. Homes built with one-car garage shall provide one additional parking space within a common area that shall be depicted during the subdivision review process.
G) Both units within duplex shall have minimum four-foot-deep covered entry.
H) An administrative review of architectural drawings and typical landscape plans is done by the city manager or their designee prior to building plan submittal to ensure compliance with intent of the ordinance. Further review and approval by mayor and council will follow, if necessary.
808.3. Subdivision standards for RD district. All subdivision developments within RD district shall meet the following:
A) Entire yard (front, side and rear) of each lot shall be sodded.
B) All utilities shall be located underground.
C) Five-foot sidewalks along both sides of interior streets.
D) Street lights.
E) Curb and gutter.
F) 25-foot buffer along all existing right-of-way, to include a vegetated berm.
G) Developments in excess of 50 lots shall have a minimum of two subdivision entrances.
H) All developments within a RD district shall be considered as residential subdivisions with only one residential structure allowed per lot and the development shall comply with the City of Lovejoy subdivision regulations.
I) All streets within a RD district shall be considered as public streets and, accordingly shall be built to the City of Lovejoy requirements for public streets, including but not limited to, right-of-way dimensions, pavement width and construction materials and methods.
J) Deed restricted HOA.
808.4 Permitted structures and uses for RD district.
A) Two-family dwellings (duplexes)
B) Those permitted structures and uses common to all residential districts as stated in section 801.1.
808.5. Accessory structures and uses for RD district. Those accessory structures and uses common to all residential districts as stated in section 801.2.
History
(Ord. No. 2018-01, § 1(808), 1-8-2018)
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.