--- title: Lovejoy Zoning Ordinance, Sec. 901. Landscaping and buffer areas collection: local-codes id: local-code:lovejoy/zoning/901 cite_as: Lovejoy, Ga., Zoning Ordinance ยง 901 canonical_url: https://georgiacommons.org/code/local/lovejoy/zoning/901 md_url: https://georgiacommons.org/code/local/lovejoy/zoning/901.md text_url: https://georgiacommons.org/code/local/lovejoy/zoning/901/text source_url: https://library.municode.com/ga/lovejoy/codes/code_of_ordinances date: 2026-11-11 status: active jurisdiction: city:lovejoy jurisdiction_name: Lovejoy place_fips: "1347616" corpus_version: local-codes-lovejoy-af944e75bb6f publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/lovejoy/zoning/~appendix-a/~article-ix.md previous: https://georgiacommons.org/code/local/lovejoy/zoning/822.md next: https://georgiacommons.org/code/local/lovejoy/zoning/902.md index: https://georgiacommons.org/code/local/lovejoy.md branch: zoning edition: As published by Municode, retrieved 2026-11-11 edition_date_kind: retrieved source_publisher: Municode version_id: local-code:lovejoy/zoning/901@2026-11-11-e8b6f7fb5f --- # Lovejoy Zoning Ordinance, Sec. 901. Landscaping and buffer areas > As published by Municode, retrieved 2026-11-11 > The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included. Part of: Appendix A - ZONING / Article IX - SPECIAL PROVISIONS 901.1. Purpose. It is recognized that the adjacent location of certain land uses may create an incompatible situation that can be mitigated by the installation of a planted buffer. An incompatible situation can arise due to the location of commercial or industrial uses adjacent to residentially zoned land, or to a lesser extent due to location of mobile home parks or multiple-family residences adjacent to single-family residential districts. Therefore, when land is to be developed for a use creating an incompatible situation, or when a use deemed incompatible is modified or expanded, a buffer shall be, provided along all side and rear property lines to insulate adjacent properties from adverse impacts. The required buffer shall provide necessary visual privacy for the conduct of residential lifestyles in an undisturbed environment, and shall provide for the protection and preservation of property values in residential districts. 901.2. Situations requiring buffers. The following situations constitute creation of incompatibilities and are subject to buffer requirements of this appendix: (1) The location of commercial or industrial land use directly adjacent to residentially zoned land. (2) The location of mobile home parks, duplex developments or multiple-family developments directly adjacent to land zoned for single-family residences. The city council or zoning administrator may require a buffer between other districts or land uses when it is determined that an incompatible situation exists or may occur as a result of a development activity. 901.3. General requirements. Buffers shall be established and maintained by the owner of the property containing the incompatible land use. The determination of incompatibility shall be based upon the existing character of the area in which the proposed action takes place. For example, proposed development or modification of commercial or industrial land use adjacent to an area developed as residential shall require the owner of the commercial or industrial property to install and maintain the buffer. If, however, nonresidentially zoned land is rezoned for development of residences and this property is located adjacent to land developed as or zoned for nonresidential use, the owner of the property to be rezoned for residences shall be required to install and maintain the buffer. The requirements for buffers are as follows: (1) Where commercial or industrial land uses are contiguous with land zoned for singlefamily residential use, the minimum width of the required buffer shall be 50 feet. (2) Where commercial or industrial land uses are contiguous with land zoned for mobile home parks, duplexes or multiple-family residences, the minimum width of the required buffer shall be 25 feet. (3) Where mobile home parks, duplexes or multiple-family land uses are contiguous with land zoned for single-family residences, the minimum width of the required buffer shall be 50 feet. (4) The minimum width of the required buffer for sanitary landfills shall be 100 feet. (5) Any new airport shall have a 3,000-foot buffer area around the entire periphery of the airport. This buffer area is to consist of natural vegetation. However, if a portion of this buffer area is void or vacant of adequate vegetation, then this area is to be planted to match the highest natural vegetation in the 3,000-foot area. In all other instances, the minimum width of a buffer as determined by the city council shall not be less than 25 feet. Vegetation attaining a minimum height in excess of that required herein might be required to mitigate the impacts of certain projects. The required buffer can be incorporated into the yard setback as specified in the appropriate zoning district. Where a buffer is required, the zoning administrator or city engineer shall evaluate the existing vegetative and topographic conditions, development and zoning to make a determination as to whether a natural buffer or planted buffer is to be required. If the zoning administrator or city engineer determine that the existing vegetation in the area where the buffer is required is of sufficient height, density and width as to accomplish the aforementioned purpose of the buffer and substantially comply with the buffer specifications stated herein, then the zoning administrator or city engineer may require a natural buffer. However, if the zoning administrator or city engineer determine that the existing or natural vegetation is not sufficient, then a planted buffer (possibly including fence, earth berm or similar such barrier) may be required. Once the developer/property owner has staked the natural buffer or, in the case of the planted buffer, installed the buffer and the city engineer has approved the buffer, then this buffer is to be considered to be an undisturbed buffer. Minor maintenance or development activity (such as a drainage easement, sewer line connection, etc.) may be authorized by the zoning administrator or city engineer upon request. No area in which a buffer is required by this appendix shall be disturbed without first obtaining approval from either the zoning administrator or city engineer. 901.4. Minimum specifications. The following are minimum specifications for required buffers. Buffers shall: (1) Be depicted in detail (the type and location of natural and planted vegetation are to be illustrated) on each site plan or plat prior to approval, and shall be designated as a permanent buffer. (2) Not be disturbed by grading, property improvements or construction activities except where necessary to prevent a nuisance, or to thin such natural growth, where too dense to permit normal growth, or to remove diseased, misshapen, or dangerous and decayed timbers. Any contemplated disturbance shall first be brought to the attention of the zoning administrator or city engineer and formal approval secured prior to initiating activity within required buffer areas. (3) Utilize existing vegetation in an undisturbed state where it has been determined that existing vegetation is appropriate for inclusion within the buffer strip, or when required shall be supplemented with approved, additional planting. (4) Retain the natural topography of the land, except when a portion must be cleared and graded as required by the local law to prevent soil erosion or sedimentation. (5) Be completely installed in accordance with the approved plan prior to issuance of the certificate of occupancy. (6) Not be used for temporary or permanent parking or loading, other than for provision of drainage improvements as mandated by local law, or for a structure other than a fence. (7) Attain a minimum height of six feet within three years of the planting date. (8) Be subject to plan approval by the zoning administrator or city engineer prior to installation of a planted buffer. 901.5. Buffer composition. In those instances where the natural vegetation and topography are insufficient to achieve the desired level of screening as determined by the zoning administrator or city engineer, a planted buffer shall be provided and shall consist of plant material of such growth characteristics as will provide an acoustical and visual screen. The following plants are suggested for use as part of the screening buffer: (1) Trees. Yaupon holly (Ilex vomitoria). American holly (Ilex opaca). Eastern red cedar (Juniperus virginiana). Laurel cherry (Prunus caroliniana). Arizona cypress redbay (Persea bordonia). Virginia pine. (2) Shrubs. Cleyera (Cleyera japonica). Euonymus (Euonymus.japonicus). Japanese privet (Ligustrum japonica). California privet (Ligustrum). European privet (Ligustrum vulgare). Southern wax myrtle (Myrica cerifera). Northern bayberry (Myrica Pennsylvania). Pittosporum (Pittosporum tobira). Japan yew (Podocarpus macro phyuus). Red tip (Photinia). (3) Ground cover. Shore juniper (Juniperus contorta). Periwinkle (Vince minor). Lippia (Lippia nodiflora). Evergreen candyturf (Iberis sempervirens). Other evergreen plant materials having the same growth characteristics as the aforementioned may be substituted subject to approval by the zoning administrator or city engineer prior to installation. 901.6. Maintenance. The buffer required by this appendix shall be guaranteed for the duration of the incompatible land use, or until such use changes to a compatible type. Necessary trimming and maintenance shall be performed to maintain the health of the plant materials, to provide an aesthetically pleasing appearance, and to ensure that the buffer serves the purpose for which it was intended. 901.7. Exceptions. The zoning administrator and/or the director of transportation and development may grant a reduction in the size of the required buffer by up to 50 percent, provided a barrier of at least eight feet in height is provided in the form of: (1) A solid wooden fence; or (2) An earthen berm; or (3) A combination of a solid wooden fence and earthen berm. Plans for this barrier must be submitted and approved by the zoning administrator or the director of transportation and development prior to granting of the exception. In unique situations, the zoning administrator or director of transportation and development may grant further reductions in the size of the required buffer down to zero feet. Examples of such unique situations include, but are not limited to, the following: (1) A substantial topographic difference between the adjacent land uses. This difference must be of such magnitude as to make a buffer and/or fence impractical. (2) Both properties have substantial frontage along major roadways, the area is changing its development character, and the residential use is unlikely to remain as such for the anticipated life of a buffer (at least ten years). (3) The residential use is nonconforming and/or deteriorating. (4) The commercial/industrial site is already developed. The zoning administrator and/or director of transportation and development may establish such conditions for granting approval of the buffer reduction as the situation warrants to achieve the intent of this appendix. At least seven days before such a decision shall be made, the subject property shall have a sign posted thereupon inviting comments on the proposal.