--- title: Madison Zoning Ordinance, 642.83. Architecture collection: local-codes id: local-code:madison/zoning/642.83 cite_as: Madison, Ga., Zoning Ordinance § 642.83 canonical_url: https://georgiacommons.org/code/local/madison/zoning/642.83 md_url: https://georgiacommons.org/code/local/madison/zoning/642.83.md text_url: https://georgiacommons.org/code/local/madison/zoning/642.83/text source_url: https://www.madisonga.com/DocumentCenter/View/5319/20250908_CityofMadisonZoningOrdinanceText_Adopted date: 2026-11-14 status: active jurisdiction: city:madison jurisdiction_name: Madison place_fips: "1349196" corpus_version: local-codes-madison-a9df2e4b5022 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/madison/zoning/~article-vi.md previous: https://georgiacommons.org/code/local/madison/zoning/642.82.md next: https://georgiacommons.org/code/local/madison/zoning/642.84.md index: https://georgiacommons.org/code/local/madison.md branch: zoning edition: As posted on the city's website, retrieved 2026-11-14 edition_date_kind: retrieved source_publisher: city website version_id: local-code:madison/zoning/642.83@2026-11-14-96e57183e8 --- # Madison Zoning Ordinance, 642.83. Architecture > As posted on the city's website, retrieved 2026-11-14 Part of: Article VI - USE PROVISIONS BY DISTRICT A. General Criteria for Conceptual Planning. (1) Architecture should reflect Madison's traditional and/or historic built environment, specifically in terms of scale, mass, form, materials, fenestration, and ornamentation (see definitions). (2) Appropriate building orientation and setback are integral aspects of site planning, and should also be incorporated during architectural design. (3) In areas where new structures are adjacent to and visible from roadways, architecture shall adhere to the standards set forth below and, to the extent deemed applicable by the Corridor Commission, to the Madison Historic Preservation Manual. (a) General. In general, new structures shall be designed consistent with traditional and historic features associated with the building type. (b) Orientation. Most Madison buildings face the street. New construction should reflect this pattern. In instances of the use of an access road, the Commission may consider alternative orientation proposals for buildings not visible from the public right-of-way. (c) Setback. Historic commercial and institutional properties have very defined setbacks, and few properties deviate from this established facade line. Properties that deviate detract from the streetscape. New construction and redevelopment shall closely adhere to the established facade line. Although the setback may not be the same as in historic areas, similar setbacks create the desired harmonious streetscape such as that found in the historic district. (d) Scale. One-story buildings are typical in most corridor areas, and these are preferred. The scale of the structure should be proportional to setback. (e) Mass. A building's proportions will be compared with other buildings in the vicinity, and with the size of the lot. If a proposed building is over 10,000 sq. ft., or has a facade greater than one hundred (100) feet in length, then setbacks, fenestration, and other techniques shall be used to minimize the visual impact of the building. (f) Form. New structures should be rectilinear forms generally. Post-modern, mall-like towers are inappropriate. Parapet roof forms are preferred, as large expanses of flat roofs should not be visible, and coverage of large expanses of roof with gable or hip forms makes the roof too prominent. (g) Materials. Brick and wood siding are the most common traditional building materials in the Madison area. Brick is the preferred exterior material. Materials having a wood siding appearance, such as hardiboard and hardiplank, are compatible substitutions provided that the proposed reveal is similar to that of existing historic examples. Aluminum and vinyl siding are not permitted. Stucco, not including E.I.F.S., is acceptable in limited areas (e.g. parapets) or as full exterior surface for architectural styles and forms reflecting Madison’s historic architecture that traditionally utilized stucco (e.g. religious architecture, Art Modern and Art Deco buildings). (h) Fenestration. The spacing and placement of architectural bays and openings, and the solid-to-void ratio (wall-to-window), should conform to the general proportions characteristic of traditional buildings. Facades greater than one hundred (100) feet in length must incorporate wall plane projections or recesses thereby creating bays, said bays forming a different plane by at least one (1) foot. No uninterrupted length of facade shall exceed one hundred (100) feet. The facade of a main building facing a public street shall feature at least one (1) public entrance. Where a main building faces more than two (2) public streets, an entrance for each side may be proposed. To avoid box-like buildings, windows and other features are important to obtain the traditional solid to void ratio. Facades that face public streets shall have arcades, display windows, entry areas, awnings, or other similar features along no less than sixty percent (60%) of their length. The ground floor facade must be transparent between the height of three (3) feet and eight (8) feet above the walkway grade for no less than sixty percent (60%) of the horizontal length of the building facade. Where additional establishments will be located within or adjacent to the principal building, the solid to void criteria set forth above apply to each individual facade. All windows shall be recessed and shall include visually prominent framing features. (i) Ornamentation. Detailing found upon local buildings should serve as a model for new design elements, including but not limited to decorative masonry work, accent masonry, brackets, knee braces, etc. Limited use of glass block, alternative masonry blocks, stucco, and synthetic stucco may be considered for the creation of building details. Building facades should include a repeating pattern that shall include no less than three (3) of the following elements: 1) color change, 2) texture change, 3) material module change (shape), or 4) expression of architectural or structural bay through a change in plane no less than one (1) foot in width, such as an offset, reveal, or projecting rib. At least one (1) of these elements shall repeat horizontally. All elements should repeat at intervals of not more than thirty (30) feet, either horizontally or vertically. Recessed panels (also referred to as traditional signboard areas) should be incorporated into the fenestration and ornamentation if attached wall signs are proposed. B. Area Specific Criteria. (1) Commercial Corridor. Properties less than three (3) acres shall follow a frontage setback of seventy-five (75) feet. Properties greater than three (3) acres should reserve two (2) or more outparcels for future development to insert buildings closer to the roadway. Where additional stores will be located within the main building, each such store shall have a least one exterior public entrance. (2) Industrial Corridor. Properties less than three (3) acres shall have a frontage setback of eighty (80) feet. Properties greater than three (3) acres shall have a frontage setback of at least one hundred and twenty (120) feet. Buildings in this area may propose alternative building forms provided that all landscaping requirements are fully met. Alternative materials for elevations not visible from public areas may be presented. Only one public entrance is required, specifically on the elevation facing the primary road. Transparency of sixty percent (60%) of the horizontal length of the facade and recessed windows is imperative.