P-1 (2) P-2 (2) C-1 (11) C-2 C-3 C-4 LOT Lot area, min (1) 10,000 sq.ft. 10,000 sq.ft. (9) none 7,000 sq.ft.(9) 1 acre (9) 1 acre Lot area, max (1) 20,000 sq.ft. 20,000 sq.ft. 20,000 sq.ft. 10,000 sq.ft. 10 acre 10 acre Lot coverage, max 60% 60% 100% 60% 60 % 60% Lot width, min 60 ft. 60 ft. 30 ft. 60 ft. 60 ft. 60 ft. Lot width, max 200 ft. 200 ft. 200 ft. 100 ft. 500 ft. 300 ft. Lot frontage, min 60 ft. 60 ft. 30 ft. 60 ft. 60 ft. 60 ft. YARD Setback, front yard (3) 20 ft. 20 ft. 0 ft. 75 ft. 75 ft. 75 ft. min Setback, side yard, min (4) (10) 10 ft. 10 ft. 0 ft. 15 ft. (5) 15 ft. (6) 15 ft. Setback, rear yard, min 20 ft. 20 ft. none 30 ft. (5) 15 ft. (6) 15 ft. BUILDING Building height, max (7) 35 ft. 35 ft. 35 ft. 25 ft. 35 ft. (12) 35 ft. (11.1) Building floor area, min (8) 1,000 sq.ft. 1,000 sq.ft. 500 sq. ft. 1,000 sq.ft. 3,500 sq.ft. 1,000 sq.ft. Building floor area, max (8) 10,000 sq.ft. 10,000 sq.ft. 8,000 sq.ft. 8,000 sq.ft. 65,000 sq.ft. 65,000 sq.ft. Building width, max 80 ft. 80 ft. 60 ft. 100 ft. 150 ft. 230 ft. (1) Encompasses area for accessory buildings and uses, including parking, loading and unloading space, storage and parking, screening, lighting, and stormwater management measures. The minimum lot area cited in this Article shall be increased in all situations where county sanitation requires a larger lot for proper septic tank operation. (2) Single-family dwellings shall comply with the lot requirements set forth for the R2 District. (3) For properties within the HPO or CDO zoning districts, the setback is established by the designated design review board to maintain the established building line along a historic block or design corridor. (4) On corner lots that abut a residential district or use, there shall be a side yard equal in depth to the required front yard of the residential district. (5) A ten (10) foot landscaped and fenced opaque buffer strip is required if lot abuts residential district or use. (6) A twenty (20) foot landscaped and fenced opaque buffer strip is required if lot abuts residential district or use. (7) Church spires, belfries, cupolas, monuments, water towers, chimneys, flues, flagpoles, television antennae, and radio aerials are exempt. (8) This measurement specifically is meant to apply to the ground floor area. (9) For attached dwelling units, there must be a minimum of 0.25 acres per unit. Refer to section 850 for details. (10) The Zoning Administrator may approve an administrative variance for side setback to accommodate in-line construction, meaning rearward extension of an existing side wall which does not further encroach on the side yard and meets the rear yard setback. (11) In the Downtown Commercial District (C-1), residential use of a building is permitted provided that: a) the principal use of the building is non-residential, evidenced by a non-residential occupancy of a minimum of 51% of the gross square footage of the building; and, b) the non-residential occupancy is a minimum of 1600 sq. ft., occupies the full width of building’s ground floor on the façade; and c) the residential occupancy shall utilize a primary access other than the façade (i.e. secondary or rear elevation), d) provided all requirements of this section are met, one bedroom lofts may be 500-714 sq. ft (micro-lofts) provided these units occupy no more than 25% of the gross square footage of the floor on which they are located in an existing property where a parking space per said unit is provided on the property or on an adjacent property. (11.1) Any C4 property within 2500 feet of an intersection between Interstate 20 and a state highway may have a building height of fifty (50) feet being measured from the highest point of the building along the elevation with greatest distance from grade but not including exemptions from note 7, provided the site allows for adequate access of emergency fire vehicles. (12) Height may be up to 45 ft provided the following conditions are met: a- Shall be situated on US Hwy 441 or along the US Hwy 441 bypass and b- Shall be located on the south side of the US 441 bypass and west of Mary Magnan Blvd or south of the intersection of US Hwy 441 and the US Hwy 441 Bypass c- Limited to Hotels 700.3 I, I-1, and I-2 Dimensional Requirements (also see buffer requirements): The following matrix delineates the dimensional requirements for the specified industrial zoning districts. For the matrix of use provisions by district, see Article VI. For supplementary standards for specific uses, see Article VIII.