--- title: Madison Zoning Ordinance, Section 700.3. Table 13 – Industrial Zoning Districts and Heavy Commercial Zoning District Dimensional Requirements collection: local-codes id: local-code:madison/zoning/700.3 cite_as: Madison, Ga., Zoning Ordinance § 700.3 canonical_url: https://georgiacommons.org/code/local/madison/zoning/700.3 md_url: https://georgiacommons.org/code/local/madison/zoning/700.3.md text_url: https://georgiacommons.org/code/local/madison/zoning/700.3/text source_url: https://www.madisonga.com/DocumentCenter/View/5319/20250908_CityofMadisonZoningOrdinanceText_Adopted date: 2026-11-14 status: active jurisdiction: city:madison jurisdiction_name: Madison place_fips: "1349196" corpus_version: local-codes-madison-a9df2e4b5022 publisher: Georgia Commons, an independent project of Georgia Civic Data. Not the State of Georgia. Not legal advice. up: https://georgiacommons.org/code/local/madison/zoning/~article-vii.md previous: https://georgiacommons.org/code/local/madison/zoning/700.2.md next: https://georgiacommons.org/code/local/madison/zoning/710.md index: https://georgiacommons.org/code/local/madison.md branch: zoning edition: As posted on the city's website, retrieved 2026-11-14 edition_date_kind: retrieved source_publisher: city website version_id: local-code:madison/zoning/700.3@2026-11-14-85e7e8ea24 --- # Madison Zoning Ordinance, Section 700.3. Table 13 – Industrial Zoning Districts and Heavy Commercial Zoning District Dimensional Requirements > As posted on the city's website, retrieved 2026-11-14 Part of: Article VII - DIMENSIONAL REQUIRMENTS AND EXCEPTIONS Notes for Table 13, Section 700.3: (1) Encompasses area for accessory buildings and uses, including parking, loading and unloading space, storage and parking, screening, lighting, and stormwater management measures. (2) For properties within the CDO zoning district, the setback is established by the designated design review board to maintain the established building line along a design corridor. (3) On corner lots which abut a residential or commercial district or use, there must be a side yard equal in depth to the required front yard of the abutting residential or commercial district. (4) A twenty-five (25) foot landscaped and fenced opaque buffer strip required if lot abuts commercial district or use. A one hundred (100) foot landscaped and fenced opaque buffer strip required if lot abuts residential district or use and city limits. (5) The Zoning Administrator may approve an administrative variance for the front and side setbacks to accommodate inline construction, meaning sideward or rearward extension of an existing front or side wall which does not further encroach on the front and/or side yard and meets all other setbacks. (6) Structural elements or structures such as church spires, belfries, cupolas, monuments, water towers, chimneys, flues, flagpoles, television antennae, and radio aerials are exempt. In such instances, the setback in closest proximity must be at a minimum equal to or greater than the height of said structural element or structure so that in the event of structural failure the structural element or structure could do so on the property on which it is constructed. I I-1 I-2 LOT Lot area, min (1) none 5 acres 10 acres Lot area, max (1) 5 acres 10 acres 75 acres Lot coverage, max 60% 60% 60% Lot width, min none none none Lot width, max none none none Lot frontage, min 50 ft. 75 ft. 100 ft. YARD Setback, front yard (min) (2) highways and arterials 150 ft. min 200 ft. min 250 ft. min Setback, front yard (min) (2) collectors and other streets 100 ft. min 100 ft. min 100 ft. min Setback, side yard (3)(4)(5) 25 ft. min 50 ft. min 50 ft. min Setback, rear yard (3)(4) 25 ft. min 50 ft. min 50 ft. min BUILDING Building height, max (6) 50 ft. 50 ft. (7) 50 ft. (7) Building floor area, min (8) none none none Building floor area, max (8) 50,000 sq.ft. 100,000 sq.ft. 400,000 sq. ft. (9) Building width, max 250 ft. 500 ft. 500 ft. (10) (7) Beyond the building midpoint, the building height may be extended to a maximum of seventy-five (75) feet to accommodate upper floor space not used for human occupancy (i.e. offices, etc.). For any height exemption herein, the setback in the closest proximity to the building extension must be at a minimum equal to or greater than the highest point of the building extension. (8) This measurement specifically is meant to apply to the ground floor area. (9) Subject to conditional use approval as prescribed in Section 1125, the building floor area maximum may be increased, not to exceed, five hundred thousand (500,000) sq. ft. (10) Along highways and arterials only.