McDonough · Zoning Ordinance
Part IV - : ENFORCEMENT AND PENALTIES / Title 17 - ZONING / Chapter 17.120 - SITE DESIGN STANDARDS
17.120.028. Buffer area standards.
About this text
- As published by Municode, retrieved 2026-11-11
- The enacted text only: the publisher's notes (editor's notes, state law references, cross references) are not included.
A. In any residential development, all buffers must be fenced off on the development side with a basic rail or crossbuck fence. The fencing is required so adjacent property owners within the development do not absorb any required buffering into their property.
B. In any commercial or industrial zoned district that abuts a residential zoned district, the owner of the property with a commercial or industrial zoning shall be required to maintain a buffer zone between the commercial property line at all points where it intersects with a property line of property zoned residential.
C. Buffer areas shall be established and maintained by the property owner under the following provisions:
1. A lot zoned or used for a residential, office, institutional, and/or commercial, or occupied by a residential use shall
provide a twenty-five-foot-wide undisturbed buffer along all property lines adjoining property zoned for or used by 'For-Sale' residential purposes.
Where commercial or industrial districts or developments abut RM-75 zoning
districts, the same buffer requirements apply. The buffer shall be in addition to the required building setback line.
2. When a new, "for-sale" development is proposed adjacent to an existing, nonresidential use with no buffer present, the twenty-five-foot-wide buffer must be provided by the residential development.
3. If a twenty-five-foot-wide buffer has been provided on the property adjacent to a
proposed, nonresidential development, the buffer requirement may be waived with
the approval of the director.
D. Except as otherwise provided, herein, buffer strips shall be preserved in their natural undisturbed state, except that sparsely planted buffers shall be enhanced with additional plant material. Enhancement plants must provide an opaque screen within two (2) years of planting and must consist of trees, shrubs, and groundcover plants meeting the following standards:
1. Plant selection will consist of forty (40) percent evergreen species and sixty (60) percent deciduous species.
2. Deciduous trees must be a minimum of two (2) inch caliper and six (6) feet in height at time of installation.
3. Evergreen trees must be a minimum of six (6) feet in height at time of installation.
4. Shrubs must be a minimum of thirty-six
(36) inches in height at time of installation.
5. Plants will be spaced a maximum of eight (8) feet on center or as approved by the director.
6. Plantings shall be designed with a plant palate containing a mixture of colors,
textures, and heights.
E. Undisturbed buffers shall not contain any surface parking or storm water, detention facilities, or any structures except that the director may approve underground facilities within the buffer or the crossing of the buffer for the purpose of extending utilities.
F. The director may approve vegetated runoff reduction measures within the buffer. The planting requirements above may be varied to accommodate vegetated runoff reduction measures as part of an approved stormwater management plan, if properly designed to provide stormwater management and screening functions.
G. Stream buffers must be replanted where disturbed for approved access and utility crossing. Replacement plantings must be native and be arranged to have a natural appearance.
H. All buffer plantings are subject to the approval of the director.
I. The requirements for a fence or wall may be waived by the director upon presentation of field survey data by the property owner or developer, which shows that construction of the fence or wall would destroy existing vegetation which provides visual screening between the development and the adjoining residential district.
1. If required, the minimum opaque fence or wall height shall be six (6) feet for developments in C-1, C-2, C-3, OI, RTD,
MU, M-1 and M-2 districts when abutting a residential use.
J. Required buffer areas shall not be used for parking or a structure other than a fence or drainage improvements required by the city.
However, a buffer area may be used for vehicular access and utility easements if these uses are provided approximately perpendicular to the greater distance of the buffer area and for drainage improvements required by the city based upon competent engineering studies which show these improvements to be necessary, upon approval of the director.
K. Except as otherwise provided, the natural topography of the land shall be preserved and natural growth shall not be disturbed beyond that which is necessary to prevent a nuisance, to thin natural growth where too dense for normal growth, or to remove diseased, misshapen or dangerous and decayed timbers. However, a slope easement may be cleared and graded where required to prevent soil erosion upon approval of the director; this easement may cover no more than twenty (20) percent of the required buffer area and shall be immediately replanted upon completion of easement improvements.
L. Where the conditions described above cannot be met by reason of the topography of the land or of the prior removal of or lack of vegetation and foliage, the owner of the buffer area may install a permanent screen of deciduous and evergreen plantings, so designed and developed to provide visual screening between the property described herein. These plantings shall consist of deciduous and evergreen trees or shrubs not less than six (6) feet in height, or trees or shrubs which will, in normal growth, attain a height of six (6) feet within two (2) years. Plantings shall form a hardy screen, dense enough and high enough both to interrupt vision and to diffuse the transmission of sound.
M. Tree protection measures shall be followed in accordance with Chapter 17.160.
History
(Ord. No. 25-01-02, § 1, 1-2-2025)
Read this code where it is posted (Municode) The source is the city's code as its publisher or its own website posts it. Check it there for later changes.